Console Error Code Troubleshooting - Bowflex TreadClimber TC10 Service Manual

Hide thumbs Also See for TreadClimber TC10:
Table of Contents

Advertisement

Console Error Code Troubleshooting

Error Message
H03. Critical Motor Current
H05. Communication Lost
H06. Multiple communication
Packets Failed
H07. System Over Speed
H08. No Tach is Plugged in
H11. Power supply Supply Low
H12. Memory Initialization failed Software update failed or MCB is not
H13. Hardware Failure
H15. Over Current
Description
Motor Control Board (MCB) saw
Critical Current
Communication issue with MCB
Communication issue with MCB
Over speed condition was detected.
MCB detected that there was no Tach
plugged in.
MCB Saw that The one of it's power
supply is under operation voltage
programmed
MCB detected that one of the main
hardware components has failed or is
not working properly.
MCB Saw excessive current during
workout that could potentially damage
the motor or heat up
Resolution
1. What version of code?
2. Does this happen within a few seconds after the
belts starts moving? with user on it? without user on
it? If yes, replace Motor Control Board (MCB).
3. If no, check the Motor wiring connection and the
AC wiring connection.
1. Version 1.00? Does it happen during power UP?
If yes on both, power up the console, unplug the
communication cable from the MCB. Plug the cable
back in. Did H05 go away? Did another error appear?
2. Disconnect the communication cables at the top
of the right upright. Reconnect the cables. Did H05
go away? Did another error appear?
3. Contact Customer Service.
1. Contact Customer Service and file an Advanced
Troubleshooting Form.
1. Does error happen as soon as machine starts the
workout or turns ON?
-Replace MCB
2. Is this error combined with any other error?
-troubleshoot other errors along with error.
3. Is the user backpushing the belt or intentionally
pushing back on the belts?
- Avoid pushing back on the belts
4. Contact Customer Service and file an Advanced
Troubleshooting Form.
1. Check to see the Tach cable is plugged in correctly
to the MCB.
2. Check the Tach Assembly.
3. Replace Tach Assembly.
4. Replace MCB.
1. Replace MCB.
2. Replace Console.
1. Restart the device. Does issue still occur?
-If YES, replace the MCB.
-If NO, contact Customer Service.
1. Does this occur all the time?
-If YES, Check all wirings. Replace MCB.
2. Contact Customer Service and file an Advanced
Troubleshooting Form.
1. Does this issue happen without the user on the
machine?
If Yes:
-Check the motor wiring and Inlet wiring.
-Replace Motor.
-Replace MCB.
If NO:
-user weights between 200-300 at lower speeds of
0.5-2.0 MPH?
Then lube the Belt, increase shock settings (less
travel), and increase speed.
17
Console Service
Mode Option Assist
Option 8, 10, 15
8, 10, 15
15
15
8, 10, 15
8, 10, 15

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TreadClimber TC10 and is the answer not in the manual?

Questions and answers

Laurie Giangola
January 29, 2025

Where can I find a new I/O cable for the TC 10?

User image 679a3d99f3b4f
1 comments:
Mr. Anderson
February 10, 2025

The documents mention that Nautilus, Inc. provides customer service for Bowflex products. You can contact Nautilus Customer Service at (800) 605-3369 or visit www.NautilusInc.com for assistance in purchasing a new I/O cable for the Bowflex TreadClimber TC10.

This answer is automatically generated

Table of Contents

Save PDF