Open Path Eddy Covariance System
With IRGASON or EC150/CSAT3A
Quick Deploy Guide
December 2015

Advertisement

loading
Need help?

Need help?

Do you have a question about the CR3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Campbell CR3000

  • Page 1 Open Path Eddy Covariance System With IRGASON or EC150/CSAT3A Quick Deploy Guide December 2015...
  • Page 2 1. Setup tripod and mount enclosures. Datalogger Enclosure EC100 Electronics...
  • Page 3 Ground tripod and enclosures. Ground Lug Grounding Rod...
  • Page 4 3. Setup tripod or mast with CM20X Crossarm. Crossarm-To-Pole Bracket CM20X Crossarm...
  • Page 5 4. Mount the IRGASON or EC150/CSAT3A and point into the prevailing wind. IRGASON CSAT3A CSAT3A Mounting IRGASON Bracket Leveling Mounting Bracket Bubble EC150 CM20X Crossarm IRGASON Boom CSAT3A Boom Adapter Adapter...
  • Page 6 Mount the radiation shield and IRGASON or EC150/CSAT3A Temperature Probe. Radiation Shield IRGASON or EC150/CSAT3A CM20X Crossarm Temperature Probe...
  • Page 7 6. Connect gas analyzer, sonic anemometer, and temperature probe cables to EC100 Electronics. Gas Analyzer Cable Temperature Probe Cable Sonic Anemometer Cable...
  • Page 8 Insert CF card 7. Connect system wiring and insert compact flash (CF) card. Datalogger Enclosure EC100 Power and SDM Cables...
  • Page 9 Power Cable (can connect here or directly to +12Vdc power supply) SDM Cable If datalogger has SDM Cable rechargeable base, Power Cable Otherwise connect connect cable from cable from +12Vdc +17-28 Vdc or +18 Vac power supply here power supply here...
  • Page 10 Press <Esc> to activate the display. Press <Enter> to display the System Control Menu. Campbell Scientific Select “Sonic Azmth”. CR3000 Datalogger 01/01/2012, 14:00:08.4 CPU: OPEC_basic_vx_x.cr3 Running. System Control Sonic Azmth :0.00000 Change Press Source >...
  • Page 11 Enter in the azimuth (the angle in degrees between true north and the direction the IRGASON or EC150/CSAT3A points), and press <ENTER>. Press <Esc> to exit. Modify Value Campbell Sonic Azmth Scientific Current Value: 0.00000 CR3000 Datalogger New Value: 01/01/2012, 14:00:08.4 CPU: OPEC_basic_vx_x.cr3 Running.
  • Page 12 Please visit www.campbellsci.com to obtain contact information for your local US or International representative.