Download Print this page

Power Supply - Samsung STAR C0640 User Manual

Advertisement

User Guide
LAYOUT DENSITY
GUIDELINES
CONNECTION GUIDE
CONNECTION WITH

POWER SUPPLY

STAR C0640
Use recommended length for pitch between each module to achieve optimum lighting output while maintaining lowest unit
cost. Failure or misplacing will cause dimmed spots or uneven appearance of light on the surface.
RECOMMENDED CENTER OF MODULE PITCH PER MINIMUM DEPTH
60 mm
60 mm
70 mm
C
2 0
0 3
RECOMMENDED LAYOUT DENSITY PER CHANNEL WIDTH
80 mm
Maximum driver quantity per serial connection is limited. Using more quantity per run will cause overload from SMPS which
damages all connected products. This will cause voltage drop and also dimmed lighting output.
AC Input
DC Output
CAUTION
Keep extension lead
wires as short as possible.
Refer to below table for
EXTENSION OF POWER SUPPLY LEAD WIRES
Model Name
PSGE-0030-12
Output (W)
30W
Output (A)
2.5A
STAR C0640
19pcs
Recommended
VCTF1.25
Extension Wire
AWG18
Maximum Length
5M (15FT)
**PSCS-0600-12, PSCS-1000-12 are not weather-proof
Equip with protective box for outdoor use and the box should have ventilating holes
FARD lighting GmbH
Seestrasse 20
Tel. +49 - (0)3378 / 2003-0
info@fard-lighting.de
120 mm
80 mm
180 mm
C
3 0
0 2
200 mm
*Ensure that each run should have 25 modules
at max and should use another run in parallel to connect more
Power Supply
Should use thicker wires which can take larger amount of current
than the amount transmitted from the power supply unit
1st
1st
25th
25th
*When mixed run should occur, count 1(one) for C0230, C0320, and C0340
**Must count C0640 as 2(two) and keep the total counts under 50
PSGE-0060-12
PSGE-0120-12
60W
5A
37pcs
VCTF2.0
AWG14
5M (15FT)
D - 14974 Ludwigsfelde OT Genshagen
Fax +49 - (0)3378 / 2003-29
www.fard-lighting.de
120 mm
300 mm
C
3 0
0 4
400 mm
1st
1st
25th
25th
PSGE-0600-12**
120W
600W
10A
50A
73pcs
365pcs
VCTF2.0
VCTF5.5
AWG12
AWG4
5M (15FT)
15M (50FT)
2
C
6 0
0 4
1st
PSGE-1000-12**
1000W
83A
610pcs
VCTF8.0
AWG2
15M (50FT)

Advertisement