Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at:
www.upgnet.com and www.york.com
Additional rating information can be found at:
www.ahridirectory.org
WARRANTY SUMMARY
Standard 5-year limited parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replacement
or closing for new home construction.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
® ®

DESCRIPTION

This unique modular system allows the flexibility to handle any
application. These versatile MVC blowers may be used for
upflow, downflow, or horizontal left or right applications. They
may be combined with cased coils to function as a cooling only
unit or with a heat pump including electric heat for 1 and 3
phase applications.

FEATURES

COMMON MVC AIR HANDLER AND MATCH-UP CM COIL
Rigid Case Construction - An interior endoskeleton for
structural support, smooth side, and locks in insulation.
Powder-painted - G30 galvanized steel case provide a coated
edge that resists corrosion and rust creep.
Quality Construction - Structural components are made of
Aluminum or G90 galvanized steel to prevent corrosion.
Improved Insulation Design - Single piece with no external
screws to reduce thermal transmission paths to prevent
sweating. Foil faced insulation for ease of cleaning.
Case Depth - These models have 20.5" casing which provide
ease of attic access and tight applications.
MVC AIR HANDLERS
Factory Sealed - Achieves 2% or less total airflow leakage rate
at duct leakage test conditions in positive and negative
pressure for system airflow verification.
Electric Heat Kits - 6HK series of field installed electric heat
kits are available for installation-friendly and easy service
applications.
Blowers - All models use direct-drive, variable speed ECM
motors.
CM COILS
TM
Coil - Long life aluminum coils built to deliver
MaxAlloy
lasting performance, efficiency and reliability.
Thermostatic Expansion Valve - The accessory bolt-on TXV
provides easy installation to convert the indoor coil to the
required refrigerant that does not require brazing to replace or
install. Some models are available with factory installed TXV.
Thermoset Drain Pan - Low retention and positive slope for
drainage to reduce potential mold or contaminants.
Accessories - A full line of matching accessories available for
use with the blower and coils to provide for any type of
application.
5151065-YTG-H-0118

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MVC SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for York MVC SERIES

  • Page 1: Description

    COOLING & HEAT PUMPS Quality Construction - Structural components are made of MODELS: MVC SERIES Aluminum or G90 galvanized steel to prevent corrosion. Improved Insulation Design - Single piece with no external screws to reduce thermal transmission paths to prevent sweating.
  • Page 2: Table Of Contents

    5151065-YTG-H-0118 LIST OF SECTIONS NOMENCLATURE DESCRIPTION ......... . 1 M = Modular Blower PRODUCT TYPE FEATURES .
  • Page 3: Dimensions & Duct Connection Dimensions

    5151065-YTG-H-0118 DIMENSIONS & DUCT CONNECTION DIMENSIONS 12-3/16” TOP OUTLET DIMENSIONS AIR HANDLER BOTTOM INLET SERVICE DISCONNECT DIMENSIONS PANEL 20-1/2” 19-1/8” 21-1/2” C (OPENING) (OPENING) 19-1/8” C (OPENING) COIL BOTTOM OPENING DIMENSIONS 20-1/2” 19-1/8” D (OPENING) 21-1/2” A0452-002 DIMENSIONS - MVC MODULAR AIR HANDLERS & CM MULTI-POSITION FULL CASED COILS Dimensions (inches) Height Width...
  • Page 4: Cooling Capacity

    5151065-YTG-H-0118 DIMENSIONS - MVC MODULAR AIR HANDLERS & CM MULTI-POSITION FULL CASED COILS CM - Indoor Coil Multi-position MaxAlloy™ Factory Installed TXV Coils CM18ABAA1 19-1/2 14-1/2 13-1/2 13-1/2 FM TXV CM24ABAA1 19-1/2 14-1/2 13-1/2 13-1/2 FM TXV CM24BBAA1 17-1/2 16-1/2 16-1/2 FM TXV CM30ABBA1...
  • Page 5 5151065-YTG-H-0118 COOLING CAPACITY (Continued) MBH@ Evap. Temp. and Corresponding R-410A Pressure (°F/PSIG) Entering Air Models Rated CFM Dry/Wet Bulb (°F) 35/107.9 40/118.9 45/130.7 50/143.3 85/72 79.3 69.5 57.4 44.8 80/67 64.0 53.3 42.6 30.7 CM37B 1200 75/62 50.0 39.0 29.9 19.9 70/57 37.3...
  • Page 6 5151065-YTG-H-0118 COOLING CAPACITY (Continued) MBH@ Evap. Temp. and Corresponding R-410A Pressure (°F/PSIG) Entering Air Models Rated CFM Dry/Wet Bulb (°F) 35/107.9 40/118.9 45/130.7 50/143.3 85/72 100.6 89.8 78.2 64.7 80/67 83.5 73.7 59.8 48.0 CM42D 1400 75/62 67.8 55.8 44.7 32.5 70/57 52.3...
  • Page 7: Physical & Electrical Data - Cooling Only

    5151065-YTG-H-0118 PHYSICAL & ELECTRICAL DATA - COOLING ONLY Models MVC08B MVC12B MVC12C MVC14D MVC16C MVC20D Blower - Diameter x Width 10 x 8 10 x 8 10 x 8 11 x 10 11 x 10 11 x 10 1/3 HP 1/2 HP 1/2 HP 1/2 HP...
  • Page 8: Electric Heat Performance Data: 208/230-1-60 & 208/230-3-60

    5151065-YTG-H-0118 ELECTRIC HEAT PERFORMANCE DATA: 208/230-1-60 & 208/230-3-60 kW Staging Total Heat Heater Nominal kW W1 Only W1 + W2 1,2,3 @240V Models 208V 230V 208V 230V 208V 230V 208V 230V 6HK(0,1)6500206 6HK(0,1)6500506 12.3 6HK(0,1)6500806 19.7 24.1 6HK(0,1)6501006 24.6 30.1 6HK(1,2)6501306 12.5 11.5...
  • Page 9: Electrical Data For Multi-Source Power Supply: 208/230-1-60

    5151065-YTG-H-0118 ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY: 208/230-1-60 (Continued) Field Wiring Heater Heater Air Handler Amps Min. Circuit Ampacity MOP. Models Models @240V 208V 230V 208V 230V 6HK(0,1)6500206 19.9 20.7 6HK(0,1)6500506 30.8 32.7 6HK(0,1)6500806 44.0 47.3 6HK(0,1)6501006 52.4 56.6 MVC16C 6HK(1,2)6501306 65.6...
  • Page 10: Electrical Data For Single Source Power Supply: 208/230-3-60

    5151065-YTG-H-0118 ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY: 208/230-3-60 Field Wiring Air Handler Heater Min. Circuit Ampacity Heater Models MOP. Models Amps @240V 208V 230V 208V 230V MVC08B 6HK36501025 23.1 28.8 31.3 6HK36501025 23.1 31.3 33.3 6HK36501525 34.6 43.7 47.1 MVC12B 6HK36501825 41.6...
  • Page 11: Power Wiring - Line Connections

    ACCESSORIES through accessory sourcing. For optimum performance, these Refer to Price Manual for specific model numbers where not outdoor units are fully compatible with our York touch screen shown. thermostat with proprietary (patent-pending) hexagon interface. TXV Kits - Air handlers are shipped with “Flex-coils” without a For more information, see the thermostat section of the Product factory installed metering device.
  • Page 12: Limitations

    5151065-YTG-H-0118 LIMITATIONS TYPICAL APPLICATIONS These units must be wired and installed in accordance with all DOWNFLOW UPFLOW national and local safety codes. Voltage limits are as follows: HEAT Normal Operating Voltage Air Handler Voltage Range HORIZONTAL RIGHT 208/230-1-60 187-253 1. Rated in accordance with ARI Standard 110, utilization range “A”. Airflow must be within the minimum and maximum limits HEAT approved for electric heat, indoor coils and outdoor units.
  • Page 13: Typical Thermostat Connection

    3. For heat pump applications - set AC/HP jumper on air handler control board to the HP position. Two-Stage Heat Pump Wiring CONTROL WIRING - Air Handler & UPG HP Systems Two Stage H/P with York Guard VI Board & Copeland “Ultra Tech” Conventional Application - Not Hot Heat Pump...
  • Page 14: Air Flow Data - Cfm

    Airflow (CFM) indicator light (LED2) flashes once for every 100 CFM (i.e.: 12 flashes is 1200 CFM) - blinks are approximate +/- 10% of actual CFM. Subject to change without notice. Published in U.S.A. 5151065-YTG-H-0118 Copyright © 2018 by Johnson Controls, Inc. All rights reserved. Supersedes: 5151065-YTG-G-0517 York International Corp. 5005 York Drive Norman, OK 73069...

This manual is also suitable for:

Mvc08bn21Mvc12cn21Mvc12bn21Mvc16cn21Mvc14dn21Mvc20dn21

Table of Contents