Catalogue Number Configuration; Recommended Minimum Copper Size; Dimensions In Mm; Weights (Kg) - GE M-PACT Plus Manual

Air circuit breakers 400 - 4000a
Hide thumbs Also See for M-PACT Plus:
Table of Contents

Advertisement

1200
1600
20000
20000
10000
10000
5000
5000
690
690
1000
1000
8000
8000
3 & 4
3 & 4
100%
100%
S
N
H
S
1
1
2
1
50
65
80
50
50
65
80
50
50
65
80
50
50
50
65
50
40
40
60
40
50
65
80
50
50
65
80
50
50
65
80
50
50
50
65
50
40
40
60
40
50
65
80
50
40
50
50
40
143
143
176
143
143
143
143
176
143
143
143
105
143
143
105
84
84
105
84
175
105
60
287
196
351
211
128
574
392
Catalogue Number Confi guration
M
S
3
1
F
16
Ratings:
Installation: F-fi xed, W-withdrawable
Type: 1-Frame1, 2-Frame2
Pole: 3-3P
4-4P*
Breaking Capacity: S, N, H
M-PACT Plus
* Letter 'L' & 'R' only for type selection, not shown on nameplate.

Dimensions in mm

Frame
Rating
Poles
Type
Size
(A)
1
400 to 2500
3
Withdrawable
Fixed
4
Withdrawable
Fixed
2
800 to 4000
3
Withdrawable
Fixed
4
Withdrawable
Fixed
(1) Height is from mounting surface to highest part of the ACB.
(2) Depth is from the cubicle door to the back of terminals.
* 4P, Neutral on the left or right Please specify on selection form,the default
option is Neutral on right.
2000
20000
10000
5000
690
1000
8000
3 & 4
100%
N
H
S
N
H
1
2
1/2
1/2
2
65
80
50
65
80
65
80
50
65
80
65
80
50
65
80
50
65
50
50
65
40
60
40
40
60
65
80
50
65
80
65
80
50
65
80
65
80
50
65
80
50
65
50
50
65
40
60
40
40
60
65
80
50
65
80
50
50
40
50
50
176
143
143
176
176
143
143
176
143
143
105
143
84
105
84
84
105
98
224
224
163
209
490
490
347
04-400A, 08-800A
10-1000A, 12-1250A
16-1600A, 20-2000A
25-2500A, 32-3200A
40-4000A
(1)
(2)
Height
Width
Depth
440
329
422
430
342
352
440
429
422
430
442
352
440
419
424
430
432
352
440
549
424
430
562
352
2500
3200
20000
20000
10000
10000
5000
5000
690
690
1000
1000
8000
8000
3 & 4
3 & 4
100%
100%
S
N
H
S
N
1/2
1/2
2
2
2
50
65
80
50
65
50
65
80
50
65
50
65
80
50
65
50
50
65
50
50
40
40
60
40
40
50
65
80
50
65
50
65
80
50
65
50
65
80
50
65
50
50
65
50
50
40
40
60
40
40
50
65
80
50
65
40
50
50
40
50
143
143
176
143
143
143
143
176
143
143
143
105
143
143
105
84
84
105
84
84
224
224
163
418
418
490
490
347
888
888

Recommended Minimum Copper Size

In accordance with IEC 60947-2
Rating (A)
400
800
1000
1250
1600
2000
2500
3200
4000

Weights (kg)

S range
Fixed pattern
Frame 3 Pole 4 Pole 3 Pole 4 Pole 3 Pole 4 Pole
400 to 1600A
1
39
2000 to 2500A
1
43
800 to 3200A
2
53
4000A
2
53
Withdrawable
Frame 3 Pole 4 Pole 3 Pole 4 Pole 3 Pole 4 Pole
400 to 1600A
1
68
2000 to 2500A
1
74
800 to 3200A
2
90
4000A
2
113
M-PACT Plus
4000
20000
10000
5000
690
1000
8000
3 & 4
100%
H
S
N
H
2
2
2
2
80
50
65
80
80
50
65
80
80
50
65
80
65
50
50
65
60
40
40
60
80
50
65
80
80
50
65
80
80
50
65
80
65
50
50
65
60
40
40
60
80
50
65
80
50
40
50
50
176
143
143
176
176
143
143
176
143
143
105
143
105
84
84
105
418
571
571
571
888
1224
1224
1224
Copper / phase
2 x 50 x 5
2 x 50 x 5
2 x 60 x 5
2 x 100 x 5
2 x 100 x 5
3 x 100 x 5
4 x 100 x 5
4 x 100 x 10
4 x 100 x 10 + 1 x 100 x 5
N range
H range
49
39
49
/
/
54
43
54
/
/
68
53
68
53
68
68
53
68
53
68
79
68
79
/
/
85
74
85
/
/
109
90
109
90
109
128
113
128
113
128
A
B
C
X
A.7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents