Keysight Technologies Streamline Series Configuration Manual

Keysight Technologies Streamline Series Configuration Manual

Usb vector network analyzers, 2-port, up to 26.5 ghz/up to 20 ghz, compact form, zero compromise

Advertisement

Keysight Streamline Series
USB Vector Network Analyzers
P937xA 2-port, Up to 26.5 GHz
P500xA 2-port, Up to 20 GHz
Compact Form. Zero compromise.
Find us at www.keysight.com
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Streamline Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Keysight Technologies Streamline Series

  • Page 1 Keysight Streamline Series USB Vector Network Analyzers P937xA 2-port, Up to 26.5 GHz P500xA 2-port, Up to 20 GHz Compact Form. Zero compromise. Find us at www.keysight.com Page 1...
  • Page 2: Table Of Contents

    Table of Contents Keysight Streamline Series: Exceptional Performance in a Small Package ...... 3 Keysight Streamline Series Vector Network Analyzer Configurations ........ 4 Test set options ........................ 4 Hardware options ......................4 Application software ......................5 Calibration options ......................5 Accessories ........................
  • Page 3: Keysight Streamline Series: Exceptional Performance In A Small Package

    Keysight Streamline Series: Exceptional Performance in a Small Package Balance deadlines, productivity, budget and bench space with the Streamline Series. You’ll move confidently across every stage of your product’s development lifecycle by leveraging accurate and repeatable measurements, automated code capability, and a consistent, intuitive user experience. With comprehensive Keysight Services including calibration, education and consulting, these instruments enhance your solution to help you accelerate technology adoption and lower costs.
  • Page 4: Keysight Streamline Series Vector Network Analyzer Configurations

    Keysight Streamline Series Vector Network Analyzer Configurations Model Description Test port connectors P937xA Series P9370A 300 kHz to 4.5 GHz, 2-port 3.5 mm (f) P9371A 300 kHz to 6.5 GHz, 2-port 3.5 mm (f) P9372A 300 kHz to 9 GHz, 2-port 3.5 mm (f)
  • Page 5: Application Software

    Application software For P937xA For P500xA Additional information Description Series Series Automatic fixture removal S97007A S97007A Time domain analysis S97010A S97010A Basic pulsed-RF Requires hardware option 021. S97025A measurements Noise figure measurements Standard receivers are used. S97029A with vector correction Provides ability to independently set the frequency of internal sources and Scalar mixer/converter...
  • Page 6: Accessories

    Accessories For P937xA For P500xA Additional information Description Series Series Includes the tools for SMA and SMB Accessory and tool kit Y1281A Y1281A connector removal Order Option 001 for 1-slot USB Rack mount kit Y1700A-001 Y1700A-001 instruments. Includes interconnect cables for configurations using two USB Y1701A-001 Y1701A-002...
  • Page 7: Measurement Application Software

    Measurement Application Software Solid black series name indicates the feature is available on that series, while gray series name with strikethrough indicates the feature ins not available on that series. For example: P500xA Series: Available on P500xA series P937xA Series: Not available on P937xA Series Automatic fixture removal (S97007A) P937xA Series P500xA Series...
  • Page 8: Noise Figure Measurements With Vector Correction (S97029A)

    Noise figure measurements with vector correction (S97029A) P937xA Series P500xA Series This software application enables high-accuracy noise figure and noise-power measurements of amplifiers utilizing Keysight’s unique vector-source-correction technique that uses a source-impedance tuner to remove the effects of imperfect system-source match. This approach yields accuracy that surpasses that provided by the Y-factor method and other cold-source implementations, especially for in- fixture, on-wafer, and automated-test environments.
  • Page 9: Gain Compression Measurements (S97086A)

    Gain compression measurements (S97086A) P937xA Series P500xA Series The gain compression application (GCA) provides input power, output power, gain, and phase at the compression point of an amplifier over a specified frequency range. GCA’s SMART Sweep is very fast and easy-to-use. GCA also includes a guided calibration that corrects for absolute power levels, frequency response, and mismatch errors.
  • Page 10: Material Measurements

    Figure 1: 4-port configuration using two P937xA VNAs Material measurements P937xA Series P500xA Series The Keysight N1500A materials measurement suite streamlines the process of measuring complex permittivity and permeability with a vector network analyzer. Various type of measurements, such as transmission line and free space, arch reflectivity, resonant cavity, and coaxial probe are available as options.
  • Page 11: Upgrading Your System

    Upgrading Your System Upgrade kits are available to add options after initial purchase. To upgrade the USB VNAs, order the corresponding item number. To add application software, order the appropriate standalone mode numbers (S97xxxA). For P937xA Series Order for Existing Model Number User Description P9370A...
  • Page 12: Measurement Accessories

    Measurement Accessories A complete list of RF and microwave test accessories is available on our Web site: www.keysight.com/find/mta Accessories are available in these connector types: 50 Ω Type-N, 3.5 mm, 7 mm, 2.4 mm, 2.92 mm, 1.85 mm, 1.0 mm, and waveguide. Test port cables and a calibration kit should be added for a complete measurement system.
  • Page 13: Calibration Kits

    Calibration kits Coaxial measurements Mechanical calibration kits include standards, such as opens, shorts and loads, which are measured by the network analyzer for increased measurement accuracy. Choose a calibration kit for each connector type to be used. Economy, includes: Open standards (male and female) •...
  • Page 14: For Devices With 3.5 Mm Or Sma Connectors

    For devices with 3.5 mm or SMA connectors Mechanical calibration kits 85033E economy: DC to 9 GHz. Includes: 85033-60016 3.5 mm (m) load • 85033-60017 3.5 mm (f) load • 85033-60018 3.5 mm (m) open • 85033-60019 3.5 mm (f) open •...
  • Page 15 85052C precision TRL: DC to 26.5 GHz. Includes: 00902-60003 3.5 mm (m) fixed load • 00902-60004 3.5 mm (f) fixed load • 85052-60006 3.5 mm (m) short • 85052-60007 3.5 mm (f) short • 85052-60008 3.5 mm (m) open • 85052-60009 3.5 mm (f) open •...
  • Page 16 85093C mixed-connector options Port A Option Port B Option Connector type Female Male Connector type Female Male Type-N 50 Ω 3.5 mm 7-16 N4431B ECal: 300 kHz to 13.5 GHz, 4-ports. Connector Type Port A Option Port B Option Port C Option Port D Option Four 3.5 mm (f) Four Type-N 50 Ω...
  • Page 17 N755XA Series Economy ECal, 2-ports: N7550A DC to 4 GHz, 2-ports • N7551A DC to 6.5 GHz, 2-ports • N7552A DC to 9 GHz, 2-ports • N7553A DC to 14 GHz, 2-ports • N7554A DC to 18 GHz, 2-ports • N7555A DC to 26.5 GHz, 2-ports •...
  • Page 18: For Devices With Type-N Connectors

    85134H single, flexible: 2.4 mm (f) to PSC-3.5 mm (m), 53 cm, 21 inches • N4419AK20 single, flexible: 3.5 mm (m) to 3.5 mm (f), 91.4 cm, 36 inches • Z5623A-K20 single, flexible: 3.5 mm (m) to 3.5 mm (m), 91.4 cm, 36 inches •...
  • Page 19 85054B standard: DC to 18 GHz. Includes: 00909-60011 Type-N (m) fixed lowband load • 00909-60012 Type-N (f) fixed lowband load • 85054-60025 Type-N (m) short • 85054-60026 Type-N (f) short • 85054-60027 Type-N (m) open • 85054-60028 Type-N (f) open •...
  • Page 20 Electronic calibration (ECal) modules 85092C RF ECal: 300 kHz to 9 GHz, 2 ports. Includes: Option 00F: both Type-N connectors are female • Option 00M: both Type-N connectors are male • Option M0F: one female and one male connector, both Type-N •...
  • Page 21 N755XA Series Economy ECal, 2-ports: N7550A DC to 4 GHz, 2-ports • N7551A DC to 6.5 GHz, 2-ports • N7552A DC to 9 GHz, 2-ports • N7553A DC to 14 GHz, 2-ports • N7554A DC to 18 GHz, 2-ports • N755xA Series includes: Option NFF: Both Type-N connectors are female •...
  • Page 22: For Devices With 7 Mm Connectors

    For devices with 7 mm connectors Mechanical calibration kits 85050B standard: DC to 18 GHz. Includes: 00909-60008 7 mm coax termination • 85050-60006 7 mm fixed broadband load • 85050-80007 7 mm short • 85050-80010 7 mm open • 85050-80011 7 mm sliding load •...
  • Page 23 P Band P11644A standard, WR-62: 12.4 to 18 GHz. Includes: 00896-60007 P-band standard section • 00910-60002 P-band termination • 11644-20017 P-band short • 11644-20020 P-band shim • P281C adapter (included in calibration kit): WR-62 to 7 mm • K Band K11644A standard, WR-42: 18 to 26.5 GHz.
  • Page 24: Verification Kits

    Verification kits All Keysight verification kits include: Precision Z0 airline or match thru • Mismatched airline or mismatch thru • Fixed attenuators (except 85059V) • Traceable measured data and uncertainties • 85051B 45 MHz to 18 GHz 7 mm kit Includes attenuators, airline and mismatch airline with data on a USB drive for use in confirming calibrated system performance, traceable to national standards.
  • Page 25: Pc Requirements For Usb Vna Control

    For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Find us at www.keysight.com Page 25 This information is subject to change without notice. © Keysight Technologies, 2019, Published in USA, February 12, 2019, 5992-2823EN...

Table of Contents