3
Mechanical installation
Please note
An excessive temperature increase results in premature aging or damage to the motor
controller.
• Observe the specified installation clearances to ensure sufficient ventilation
(
Tab. 3.2).
CMMS-ST
– Installation clearance
1) Recommendation for optimum wiring of the motor and encoder cable: Installation clearance H1 at the bottom = 150 mm.
Tab. 3.2
Installation clearance CMMS-ST
3.3

Disassembly

Caution
Motor controller contains condensers (energy storage)
Do not disconnect connecting cables when powered. Before mounting and installation
work:
1. Switch off power to the electrical equipment via the mains switch and secure it
against being switched on again.
2. After switch-off, wait at least 1 minute discharge time and check that power is
turned off before accessing the controller.
Caution
Danger of burns from hot surfaces
Dependent on the load of the motor controller, housing temperatures > 80 °C are pos-
sible in operation.
• Touch them only in a switched-off, cooled-off status.
20
1)
H1
[mm]
100
Festo – GDCP-CMMS-ST-G2-HW-EN – 1404NH – English
L1
L2
69
9