Flybox
● Auto reset = ON/OFF: if set to ON, if a alarm condition is
activated but the measurement that activated this alarm has
dropped below the alarm threshold, the Vigilus automatically
reset the alarm indication. If set to OFF, the user must
manually reset the alarm indication, even if the measurement
that activated this alarm has dropped below the alarm threshold.
(default=ON)
● Out map: you can choose to enable one of the four outputs
available on the remote module when the alarm is activated,
useful for example to turn on an alarm light on the cockpit.
Set to zero to disable this function (default=0).
● Type: Select the type of CHT sensors installed:
TCJ: J-type thermocouples
P1K: PT1000 resistive sensors
ROX: standard ROTAX CHT sensors (default)
NOTE:
It's not possible to mix different type of CHT
sensors (i.e. 2 Rotax + 2 thermocouples).
● Unit: °C / °F: Set the unit of measure for the CHT temperatures;
choose between °Celsius (°C) or °Fahrenheit (°F).Default=°C.
● Filter: This parameter affect the readings and the gauges
displayed: a low value means that the readings will be more
fast and unfiltered (but subject to fluctuations), an high value
means that the readings will be more slow and stable (range:
0~999, default=100).
VIGILUS
®
Operating manual
-
Rev. 1.0
Instrument configuration
Cht setup menu
21