Siemens SITRANS P Brochure & Specs page 125

Measuring instruments for pressure
Table of Contents

Advertisement

Transmitters for gage, absolute and differential pressure, flow and level
SITRANS P, DS III series for level
Influence of static pressure
• on the zero point
- 250 mbar (3.63 psi) measuring cell
- 600 mbar (8.7 psi) measuring cell
- 1600 and 5000 mbar (23.2 and 72.5 psi)
measuring cells
• on the span
Measured Value Resolution
Rated operating conditions
Degree of protection (to EN 60529)
Process temperature
• Measuring cell with silicone oil filling
- High-pressure side
- Low-pressure side
Ambient conditions
• Ambient temperature
- Digital indicators
• Storage temperature
• Climatic class
- Condensation
• Electromagnetic compatibility
- Emitted interference and interference immu-
nity
Design
Weight (without options)
• To EN (pressure transmitter with mounting
flange, without tube)
• To ASME (pressure transmitter with mounting
flange, without tube)
Wetted parts materials
Housing material
High-pressure side
• Seal diaphragm of mounting flange
Measuring cell filling
Process connection
• High-pressure side
• Low-pressure side
Power supply U
H
Terminal voltage on transmitter
Separate 24 V power supply necessary
Bus voltage
• Not Ex
• With intrinsically-safe operation
Current consumption
• Basic current (max.)
• Startup current
basic current
• Max. current in event of fault
Fault disconnection electronics (FDE) available
© Siemens AG 2008
SITRANS P measuring instruments for pressure
HART
(0.3 r)% per nominal pressure
(0.15 r)% per nominal pressure
(0.1 r)% per nominal pressure
(0.1 r)% per nominal pressure
-
IP65
Note: Always take into account assignment of max. permissible working temperature to max. per-
missible working pressure of the respective flange connection!
-40 ... +100 °C (-40 ... +212 °F)
p
1bar: -40 ... +175 °C (-40 ... +347 °F)
abs
p
1bar: -40 ... +80 °C (-40 ... +176 °F)
abs
-40 ... +100 °C (-40 ... +212 °F)
-20 ... +60 °C (-4 ... +140 °F) in conjunction with dust explosion protection
-30 ... +85 °C (-22 ... +185 °F)
-50 ... +85 °C (-58 ... +185 °F)
Permissible
To EN 61326 and NAMUR NE 21
11 ... 13 kg ( 24.2 ... 28.7 lb)
11 ... 18 kg ( 24.2 ... 39.7 lb)
Poor in copper die-cast aluminium, GD-AlSi12 or stainless steel precision casting, mat. No. 1.4408
Stainless steel, mat. No. 1.4404/316L, Monel, mat. No. 2.4360, Hastelloy B2, mat. No. 2.4617,
Hastelloy C276, mat. No. 2.4819, Hastelloy C4, mat. No. 2.4610, tantalum, PTFE, ECTFE
Silicone oil
Flange to EN and ASME
Female thread ¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or
7
/
-20 UNF to EN 61518
16
10.5 ... 45 V DC
10.5 ... 30 V DC in intrinsically-safe mode
-
-
-
-
-
-
-
DS III series
PROFIBUS PA or FOUNDATION Fieldbus
0.3% per nominal pressure
0.15% per nominal pressure
0.1% per nominal pressure
0.1% per nominal pressure
-5
3 10
of nominal measuring range
Supplied through bus
-
No
9 ... 32 V
9 ... 24 V
12.5 mA
Yes
15.5 mA
Yes
Siemens FI 01 · 2009
for level
2
2/125

Advertisement

Table of Contents
loading

Table of Contents