Wagner Meters’ technology has been proven to provide some of the most accurate results in the industry when compared to this worldwide standard. Closely scrutinized and approved by numerous university...
If your species setting is not listed, contact Wagner Meters. The values entered into the MMC 205 meter omit the decimal point, so for example the Douglas Fir value of 0.48 would be “48” when programming the Species Setting Value.
If your species setting is not listed, contact Wagner Meters. The values entered into the MMC 210 meter omit the decimal point, so for example the Douglas Fir value of 0.48 would be “48” when programming the Species Setting Value.
If your species setting is not listed, contact Wagner Meters. The values entered into the MMC 220 meter omit the decimal point, so for example the Douglas Fir value of 0.48 would be “48” when programming the Species Setting Value.
R efer to the Species Setting Tables in the supplemental manual provided.
C ontact Wagner Meters Technical Services for further information for these applications. 7
...
The meter has been calibrated at the factory and should not require re-calibration. If you need to have the calibration verified, please contact the Wagner Meters Sales Department to purchase a calibration verification block if you don’t already have one. Should the meter need to have a calibration adjustment, it will need to be returned to Wagner Meters Technical Services Department.
Power: 9 volt alkaline or ni-cad rechargeable Auto Power Shut Down: 60 seconds Measurement Ranges: (MMC 205): 5% - 20% MC scaled in 1% increments (MMC 210): 5% - 30% MC scaled in 0.1% increments (MMC 220): 5% - 30% MC scaled in 0.1% increments (up to .80 SG)
FCC Compliance Statement This equipment has been tested and found to comply within the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Wagner Meters shall in no event be liable for any breach of warranty or defect in this product, which exceeds the amount of purchase price of the product. Wagner Meters shall not be liable for incidental or consequential damages for the breach of any express or implied warranty with respect to this product or its calibration.
Repair Service In the event of damage, failure, or if the unit requires re-calibration, contact Wagner Meters at www.wagnerrepairs.com or by phone for complete shipping and repair information. * If parts are unavailable to repair we reserve the right to replace the meter with an alternative model with equal or better accuracy and range ...
Need help?
Do you have a question about the MMC 205 and is the answer not in the manual?
Questions and answers