Summary of Contents for Rentokil Connect Radar

  • Page 1 This manual is based on the latest information and is provided subject to alteration. We reserve the right to change the construction and/or configuration of the product at any time without obligation and to modify earlier versions of the product. Instruction Manual Connect Radar 2017 Version 1.1 GSD-100549...
  • Page 2 When you’ve no more use for it, please dispose of the product according to your local authority’s recycling scheme. For more information, please contact your local authority or the retailer where you bought the product. Page 2 Instruction Manual Connect Radar 2017 Version 1.1 (GSD-100549)
  • Page 3: Safety Instructions

    Only use the Battery Pack Part Number 180338 that is supplied by • Rentokil. This battery pack is not rechargeable and should never be recharged. If the Radar is to be stored for a long period of time then the battery •...
  • Page 4 In such a system if the sensors fail to connect to the Control Panel they will scan for alternative Control Panels to ensure high levels of connectivity. Radar Connect AutoGate Connect Figure 1: Connect System Overview Page 4 Instruction Manual Connect Radar 2017 Version 1.1 (GSD-100549)
  • Page 5: Product Description

    Rentokil for this use under the European Biocidal Products Directive. Radar has been designed by Rentokil to exploit the travelling habits of mice as opposed to more traditional methods which target their feeding behaviours, e.g. baiting. Correctly installed units will typically be placed at wall / floor junctions, relying on a mouse’s natural...
  • Page 6: Product Functions

    The maximum number of units that can be connected to a Control Panel is 300 and so if more devices are required then an additional control panel will be required. Page 6 Instruction Manual Connect Radar 2017 Version 1.1 (GSD-100549)
  • Page 7: Installation

    High vibration due to localised machinery / fridge High levels of compressors etc could affect the performance of the unit vibration and result in false activations. Page 7 Instruction Manual Connect Radar 2017 Version 1.1 (GSD-100549)
  • Page 8 In the European regions the join time should be less than 30 seconds but in North American and some Asian regions where frequency hopping protocol is used it could take a few minutes to join the network. Page 8 Instruction Manual Connect Radar 2017 Version 1.1 (GSD-100549)
  • Page 9: Radio Check Mode

    The LED will now flash each 2.7 seconds to indicate the state of the connection to the Control Panel with the following values: Blue Good Signal level Yellow Functional but should be improved No Signal Page 9 Instruction Manual Connect Radar 2017 Version 1.1 (GSD-100549)
  • Page 10: Connect Status

    Connect Status Below are the status messages that can be sent to the Rentokil Data Portals. When the Radar has been set it will report the status of “System Sensing” to the servers. If a mouse is detected then the Radar will trigger and report “iR Triggered”...
  • Page 11: Cleaning & Maintenance

    CO canisters. The recommended cleaning product for Radar is the Universal Hard Surface Wipes (PSU01). These wipes are readily available from Rentokil Initial Supplies. Ensure that you wear protective gloves during the cleaning of the unit.
  • Page 12 Canisters that have been emptied should be marked as used by pressing a dent into the can as shown below. Note: This product contains a pressurised Carbon Dioxide (CO2) canister. I shall not be heated or incinerated. Page 12 Instruction Manual Connect Radar 2017 Version 1.1 (GSD-100549)
  • Page 13: Led Patterns

    · Occurs either after scanning or after test mode. 3 even Red flashes to Control Panel · Indicates it has been unable to make a connection. It will retry automatically Page 13 Instruction Manual Connect Radar 2017 Version 1.1 (GSD-100549)
  • Page 14: Troubleshooting

    Can not activate the Unit is in high light M ove out of the direct sunlight and Radar in technicain test conditions and the iR try again. mode sensors could be saturated Page 14 Instruction Manual Connect Radar 2017 Version 1.1 (GSD-100549)
  • Page 15: Technical Details

    Possible to mount with bracket (optional FR55) This product contains the LongReach radio module : FCC ID: 2AK3PGSD-500349 IC ID: 22407-GSD500349 These will be shown on the approval label attached to the product. Page 15 Instruction Manual Connect Radar 2017 Version 1.1 (GSD-100549)
  • Page 16: Sample Label

    Circuit board assy GSD-800731 Radar LR Connect A pproval Label GSD-200776 Sensor label - Black 85670 Battery pack 180338 LR Radar Antenna Support GSD-300814 Sensor label - Black 85670 SAMPLE LABEL Page 16 Instruction Manual Connect Radar 2017 Version 1.1 (GSD-100549)