Do you have a question about the SuperDry 90 and is the answer not in the manual?
Questions and answers
Summary of Contents for White Wing SuperDry 90
Page 1
DEHUMIDIFIERS SuperDry 90 Installation and Operations Manual WhiteWing Dehumidifiers P:+888-236-7231 Add: 300 E Valley Drive, Bristol, VA 24201...
Page 2
DEHUMIDIFIERS ※ ※ Safety Notes The WhiteWing Series Dehumidifier must always be connected using a grounded electrical connection as required for all electrical appliances. The warranty is voided and all responsibility for the operation transfers to the owner if non-grounded wiring is utilized.
※ Table of Contents Features/Specifications The SuperDry Series dehumidifier operates based on the refrigerant principle of dehumidification. Features/Specs..........................01 SuperDry 90 Identification..........................01 High COP, 2.45L/KWh Eco-Friendly R410A Refrigerant How Your SuperDry Dehumidifier Works................02 Easy access for routine maintenance Low Sound Levels <56dBA Unit Overview..........................
How Your SuperDry Dehumidifier Works The WhiteWing SuperDry Series Dehumidifier utilizes either its integral humidistat to SuperDry 90 monitor the conditioned space or a manual on/off control to energize the compressor when needed. Air is drawn across an evaporator coil. The evaporator coil is cooler than the ※...
DEHUMIDIFIERS DEHUMIDIFIERS ※Operating instructions※ Four selections are available: Humidity Setting: Adjust the humidity setpoint Timer Setting: Start Time Setup/Stop Time Setup/Cycle Time Setup Temperature Scale Switch: Choose between Celsius and Fahrenheit readings Select/OK Drain Pump Return: Return to the main menu Menu On/Off NOTE: See Section 8 for more detailed programming instructions.
Page 6
DEHUMIDIFIERS DEHUMIDIFIERS The contents of the second line alternate every 10 sec. Second screen display options: H u m i 5 0 % 0 8 9 Time remaining to Auto opening When you press the“Power Off”button, two lines of data will be displayed. The (...
Page 7
DEHUMIDIFIERS DEHUMIDIFIERS ( 2 ) Timer Settings (Timer) 2) Shut Off Time (T.offSelection). Unit will run for designated time and then turn off. a. Press the M button until the T.off button is flashing. Press“OK”to confirm. This selection allows you to set a timer for the unit to turn on or turn off. You can also set up cycle timing, which allows you to set up and repeating cycle of specific on and off durations.
The quick connector into Quick connection to draining tube the socket on the connector SuperDry 90 SuperDry 90 ※Preparing the Unit for Use※ 3 ) Firmly insert power cord into socket on top back of unit.
DEHUMIDIFIERS DEHUMIDIFIERS SuperDry 90 Release this screw at both side, and open these box locks 1) Pull up on the handle to 2) Remove the filter release and gently pull out on filter assembly. b. Pull up the bottom to open b.
Page 10
DEHUMIDIFIERS DEHUMIDIFIERS ※ At least once per year, clean pump system Basic- Hand in this 1. Press the pump button (P) to drain water from reservoir. slot to open 2. Disconnect power to dehumidifier. 3. Mix a 16 oz solution of either 1 oz bleach to 15 oz water or 4 oz white vinegar to 12 oz water.
DEHUMIDIFIERS DEHUMIDIFIERS ※Storing Your Dehumidifier※ Decrease Room Temp Unit is sensing room temperature Check Sensor Trouble codeHI : above 100F If the unit will be stored for an extended period of time: Check Sensor Cable 1. Turn unit off and allow to dry. 4.
Page 12
DEHUMIDIFIERS Seller’ s liability is limited to replacement of defective parts or components and does not include any cost of labor (including, but not limited to, labor to remove and/or reinstall any defective part), refrigerant or piping. Customer may elect to have unit fixed locally in which case required replacement parts will be sent to customer at customer’s expense.
Need help?
Do you have a question about the SuperDry 90 and is the answer not in the manual?
Questions and answers