MGF 905200 User Manual

MGF 905200 User Manual

Press testing pump

Advertisement

Art. 905200 – 905250
PRESS Testing Pump
User Manual
rev. 2.0 del 08/10/2018
This manual has been written according to following directives: 98/37/EEC, 2006/42/EEC, UNI-EN 10893
1
srl –– Via Chico Mendes, 8 – 43055 Mezzani (PR) ITALY – Tel. +39 0521-818301 – Fax +39 0521-818202
MGF
MGF
E-mail:info@mgftools.com
– Web:
www.mgftools.com
www.nebulizzare.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 905200 and is the answer not in the manual?

Questions and answers

Summary of Contents for MGF 905200

  • Page 1 Art. 905200 – 905250 PRESS Testing Pump User Manual rev. 2.0 del 08/10/2018 This manual has been written according to following directives: 98/37/EEC, 2006/42/EEC, UNI-EN 10893 srl –– Via Chico Mendes, 8 – 43055 Mezzani (PR) ITALY – Tel. +39 0521-818301 – Fax +39 0521-818202 E-mail:info@mgftools.com...
  • Page 2: Purpose Of Use

    General Informations TECHNICAL CHARACTERISTICS: Art. Modello Weight: 13,2 Kg Dimensions: 200 x 440 x 320 mm 905200 PRESS Testing Pump 60 bar 230V Max. Pressure: 60 bar Max. Flow Rate: 7 L/min (420L/h) 905250 PRESS Testing Pump 60 bar 115V High pressure hose: 1/2”...
  • Page 3: Technical Data

    TECHNICAL DATA Locate the identification plate on the machine and check that the plate data given in it are in conformity with the contents of the present table. The nameplate data must be respected during all the foreseen operations. SERVICE For any form of technical assistance you can contact us in one of the following ways: telephone: +39 0521/818301 fax: +39 0521/818202...
  • Page 4: Electrical Safety

    Warnings Warnings Read all safety instructions, operating and maintenance instructions, and the technical data of this electric tool. Failure to follow the instructions may cause electric shock, fire and / or serious injury. Keep all safety warnings and instructions for future use. 1.
  • Page 5 8. Comply with all applicable safety regulations and workplace safety regulations, especially when you feel more practical in using the instrument. Negligence or omissions can cause serious injury and permanent damage. 4. Use of the machine 1. Do not overload the machine. Do not exceed the indicated rating values. Use the machine only according to its intended use.
  • Page 6 10. Use only certified extension cables, suitably marked, with conductors of sufficient cross-section. Use extension cables with a maximum length of 10 m with conductors with a cross-section of 1.5 mm2 or a length of 10 to 30 m and with a cross-section of 2.5 mm2.
  • Page 7: Protection Devices

    Avoid discharging hazardous wastes into drains PROTECTION DEVICES PPE such as gloves, shoes and goggles are necessary to reduce the risk of injury related to work at the construction site. During the operation of the compressor it is mandatory to use ear protectors while standing near the machine Starting Starting Before starting operations, check if the pump has been labelled with serial number and technical data.
  • Page 8: Troubleshooting

    Working suggestions Working suggestions Pressure regulation device allows working at desired pressure. For pressure adjustment, turn the left handle (“PRESS”). Minimum pressure may change, depending on incoming plant pressure. Close “TEST” valve, as the desired pressure has been reached. In this way you’ll cut off from test the pump and all the input plant, while you can continue checking pressure on gauge.
  • Page 9: Exploded Views

    Switching on, there is “hum”, but the motor doesn’t turn: immediately turn off the motor, and verify if the pump isn’t locked. Check if voltage in the electric net is corresponding with data on the label. Remember that long power cords may cause voltage losses.
  • Page 10 srl –– Via Chico Mendes, 8 – 43055 Mezzani (PR) ITALY – Tel. +39 0521-818301 – Fax +39 0521-818202 E-mail:info@mgftools.com – Web: www.mgftools.com – www.nebulizzare.com...
  • Page 11: Spare Parts

    Conformity Declaration Conformity Declaration srl Via Chico Mendes, 8 – 43055 Mezzani (PARMA) – ITALY declares that test pump (art. 905200 and art. 905250) responds to following directives: 2006/42/CE, 89/392/CE, 91/368/CE, 93/44/CE, 93/68/CE, 73/23/CE, 93/68/CE, 89/336/CE, 91/263/CE, 92/31/CE, 93/68/CE, EN-292.2, EN-60.335.1, EN-60.335.2.79.
  • Page 12 srl –– Via Chico Mendes, 8 – 43055 Mezzani (PR) ITALY – Tel. +39 0521-818301 – Fax +39 0521-818202 E-mail:info@mgftools.com – Web: www.mgftools.com – www.nebulizzare.com...

This manual is also suitable for:

905250

Table of Contents