8.7 SETTING/CHANGING TOLERANCES LIMITS
To enter the mode that changes the tolerance value, Press and hold the TOL button for 3 seconds.
The previously set value will display. The default values are +2.00mm and -2.00 mm. Press and
hold the TOL button until the underscore is below the digit you would like to change. Press and
release the TOL button to change the value of the digit to the desired value. When you are finished,
press and hold the TOL button until none of the digits are underscored and SET is flashing. Press
and release the TOL button and the new values will be set. Be aware that there are two values, the
first value to be displayed is the Upper Limit and the second value to be displayed is the Lower
Limit.
NOTE: the Lower Limit cannot be greater than or equal to the Upper Limit. (an error will be
displayed if attempted)
EXAMPLE:
For this example, we are going to change from the default values of +2.00mm and -2.00mm so that the Upper
Limit is +3.50mm and the Lower Limit is -3.50mm.
Note: Arrow pointing to the right indicates setting the Upper Limit
Press and hold TOL for 3
seconds. The previous Upper
Limit will be displayed and
SET will flash.
Press and hold TOL
until the underscore
appears under the fifth
digit.
Press and hold TOL
until the underscore is
under the fourth digit.
Press and release TOL
until the fifth digit reads
five.
www.lmicorporation.com
Press and hold TOL
until the underscore
is under the fourth
Press and release TOL
until the fifth digit reads
five.
Press and release TOL
until the fourth digit reads
three.
Press and hold TOL
until the underscore is
gone. SET will flash.
Press and release TOL
until the fourth digit reads
three.
Note: Arrow pointing to the
left indicates setting the
Lower Limit
1. Press and hold TOL until the
underscore is gone. SET will flash.
2. Press and release TOL and the Lower
Limit and arrow icon will display
Press and hold TOL until
the underscore is under
the fifth digit.
Press and release TOL
and the new Upper and
Lower Limits are set
15