(GEPS24-300U-GL)
Power Supply Features
• Supports Tetra PowerStrip, Tetra MiniStrip, Tetra EdgeStrip,
Tetra Contour, Contour LS, and Line Fit Light lighting systems
• UL: Class 2 wiring per NEC Article 725.
• Limited to use in dry and damp locations.
• The suitability of rain enclosure shall be determined if
intended for wet location.
• Minimum 5 cm (2 in.) spacing from heat producing
components required.
• Minimum 4 to side and 1 in. spacing in compartment
surrounding component required.
• Three 96 watt output banks.

BEFORE YOU BEGIN

Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
power supply.
®
RISK OF FIRE
• Use only Tetra
supply wire to make connection from Tetra
®
power supply to Tetra
LED strip.
®
• Use only approved wire for input/output connection. Minimum size
18 AWG (0.82 mm
)
2
• Follow all local codes.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [A] est conforme à la NMB-003 du Canada.
imagination at work
WARNING/AVERTISSEMENT
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation électrique à la boîte de fusibles ou au disjoncteur
avant l'entretien ou l'installation du produit.
• Assurez-vous de correctement mettre à terre l'alimentation
électrique Tetra
RISQUES D'INCENDIE
®
entre l'alimentation Tetra
Taille minimum 18 AWG (0.82 mm
• Respectez tous les codes locaux.
• Avrisques d'incendie ou de choc lectriques. Ne pas interconnecter les
bornes de sortie.
Installation Guide
.
®
®
et la bande DEL Tetra
®
).
2
24
Volt
pour faire la connexion
.
®

Advertisement

loading

Summary of Contents for GE Tetra GEPS24-300U-GL

  • Page 1: Before You Begin

    Installation Guide Lighting Solutions Volt Tetra LED Systems Power Supply ® (GEPS24-300U-GL) Power Supply Features • Supports Tetra PowerStrip, Tetra MiniStrip, Tetra EdgeStrip, Tetra Contour, Contour LS, and Line Fit Light lighting systems • UL: Class 2 wiring per NEC Article 725. •...
  • Page 2 Power Supply Installation White (neutral) To Tetra LED System Black (line) AC line Output wires Green with yellow stripe (ground) Mount power supply and remove Connect the supply wire that is Connect the AC line to the black (line) attached to the Tetra LED System to junction box cover.
  • Page 3 (1-888-69-43-533) GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting. The GE brand and logo are trademarks of the General Electric Company. © 2014 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.