Integral gain
f363
Differential gain
f366
Process upper limit
f367
f368
Process lower limit
f369
PID control feedback signal
selection
Process increasing rate
f372
(speed type PID control)
Process decreasing rate
f373
(speed type PID control)
PID forward /reverse
f380
characteristics selection
PID control reference signal
f389
selection
Override addition input
f660
selection
Override multiplication input
f661
selection
Frequency free unit display
f702
magnification
Frequency free unit coverage
f703
selection
Operation panel override
f729
multiplication gain
*1: Default setting values vary depending on the setup menu setting.
[Input /Output terminal function]
Positive logic
Input terminal
Output terminal
[FM/ pulse output and monitor output function]
FM/ Pulse output
Option No.
Communication No.
2
FD02
23
FD22
0.01-100.0 (s
0.00-2.55 (s)
0.0-fh (Hz)
0.0-f367 (Hz)
0:Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4 to 6: -
0.1-600.0 (s)
0.1-600.0 (s)
0:Forward
1:Reverse
0:fmod/ f207 selected
1: Terminal VIA
2: Terminal VIB
3: fpid
4: RS485 communication
5: UP/DOWN from external logic input
6:CANopen communication
7:Communication option
8: Terminal VIC
9,10: -
11: Pulse train input
0:Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4: fc
0:Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4: f729
0.00:Disabled (display of frequency)
0.01-200.0(times)
0: All frequencies display
1: PID frequencies display
-100-+100 (%)
Negative logic
36
37
52
53
54
55
144
145
Monitor output
Option No.
2
23
-1
)
PID control prohibition
PID integral / differential clear
PID characteristics switching
Signal in accordance of frequency command
Communication No.
FE02
Frequency setting value
FE22
PID feedback value
8
E6581879
0.20
0.00
*1
0.0
10.0
10.0
0.00
Function
Function
0
0
0
0
0
0
0