MayPole MP7423 Instruction Manual

MayPole MP7423 Instruction Manual

6v / 12v 4a electronic smart charger

Advertisement

MP7423 6V / 12V 4A Electronic Smart Charger
Instruction And Information Manual
In order to ensure correct and safe usage of your battery charger, you should read these
instructions carefully. Please store these instructions for future reference.
SAFETY
Ensure that cables are regularly inspected and kept in good condition.
Never use the battery charger if the mains lead or plug is damaged.
Never use the battery charger if the output leads or crocodile clips are damaged.
Never use the battery charger if it has been dropped or damaged in any way.
WARNING: Battery charging produces explosive gases. Prevent flames and sparks. Provide adequate
ventilation during charging.
Keep the charging area completely clear of combustible materials.
For indoor use only, do not expose to rain or any other forms of liquid or moisture.
The charger must not be used as a continuous DC power source or for any purposes other than those listed.
The charger is designed to charge Lead-Acid & AGM batteries only and must not be used for the charging
of non-rechargeable batteries.
Replacement of the mains cable should only be carried out by the manufacturer, its service agent or a suitably
qualified electrician / electrical technician in order to avoid a hazard. There are no user-serviceable parts in
this product other than the fuse in the output and input leads.
GENERAL SAFETY
This battery charger can be used by children aged from 8 years and above, and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way, and understand the hazards involved.
Children should be supervised to ensure that they do not play with this battery charger.
Cleaning and user maintenance shall not be carried out by children without supervision.
GASES
The charging process produces flammable and explosive gases - the area in which charging takes place
should be kept well ventilated. Only connect and disconnect the battery leads when the mains supply is
disconnected. Avoid flames or sparks ! Do not smoke !

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MP7423 and is the answer not in the manual?

Questions and answers

Benn Michael Lines
February 1, 2025

I have a fairly flat 12v golf trolley battery. When I apply the MP 7423 charger it appears to stay at 6v. How do I encourage the charger to charge it to 12v.

Summary of Contents for MayPole MP7423

  • Page 1 MP7423 6V / 12V 4A Electronic Smart Charger Instruction And Information Manual In order to ensure correct and safe usage of your battery charger, you should read these instructions carefully. Please store these instructions for future reference. SAFETY Ensure that cables are regularly inspected and kept in good condition.
  • Page 2: General Information

    GENERAL INFORMATION 1. Retain these instructions for future use. 2. Store this product in a dry place to avoid moisture damage. 3. There are no user-serviceable parts in this product. Opening the case is dangerous and should therefore only be carried out by qualified persons. Resultant damage to the product will result in the loss of your guarantee.
  • Page 3: When Charging Is Complete

    To avoid battery acid splashing, the cell caps should be replaced but not tightened until charging is complete. This allows any gases formed during charging to escape. It is inevitable that some minor escape of acid will occur during charging. If your battery is permanently sealed it is unnecessary to carry out these checks. 2.
  • Page 4: Technical Specifications

    For non-sealed lead-acid batteries: Inspect the liquid levels in each cell and top up if necessary, using the correct fluid. Now push home or tighten the caps. Any surplus fluid around the cell tops should be wiped off (this should be done with extreme care as it is acidic). If the battery has been removed for charging, replace it and re-connect the cables.
  • Page 5: Summary Of Operation

    Persistent fuse replacement may indicate a fault with the charger or leads. Check these before each use and do not use if worn or damaged. DECLARATION OF CONFORMITY We declare that this product conforms to the following standards EN60335-1, EN60335-2-29, EN55014, EN61000, and the following Directives 73/23 CEE, 93/68 CEE, 2004/108/EC, 2002/95/EC (ROHS) Technical Manager Maypole Ltd, August, 2015...
  • Page 6 EMAIL : sales@maypole.ltd.uk WEB : www.maypole.ltd.uk...

Table of Contents

Save PDF