The Accona is ideal for a wide range of fixed installation heating applications in the home and office environment. The Accona is ecodesign compliant; energy saving features include open window detection and a 24/ 7 electronic timer.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children of less than 3 years should be kept away unless continuously supervised.
Page 4
Specification MODEL AC500T 500/250 AC1000T 1000/500 AC1500T 1500/750 AC2000T 2000/1000 • Remove the bracket from the reverse of the heater by pinching the two tabs at the top to release it from the unit, and then unhooking the lower two tabs by tilting the bracket away from the heater.
• Once the lower lugs are located, tilt the heater back towards the bracket and align the upper bracket lugs into the corresponding slots at the top of the heater. • Insert the screws into the upper lug holes and screw down until the heater is locked into place.
3. Operation Control panel overview LO HI WO M A POWER MON TUE WED THU Set OK 1. Standby on/off 7. Manual mode active 13. Time display 2. Full/half power select 8. Automatic mode active 14. Target temperature 3. Element on indicator 9.
Page 7
The unit has a built-in battery that can retain the time for several days if the power is switched off to the unit. If the unit is off for longer periods the day & time may need to be reset upon next start up. Setting the target temperature •...
Page 8
• Select the manual operation mode by pressing the manual/auto (M/A) select button. To confirm the selection check that the “M” icon is displayed. • Press the SET select button to enter the power off time programming screen. • The hour setting will flash on the display. Use the UP/DOWN select buttons to change the desired hour for the heater to turn off and press the SET select button.
Page 9
• Select the automatic operation mode by pressing the manual/auto (M/A) select button. To confirm the selection check that the “A” icon is displayed. • Press the SET select button to enter the 24/7 timer programming screen. • The day setting will flash on the display. Use the UP/ DOWN select buttons to move between the available days and press the SET select button to confirm when the desired day to be programmed is flashing.
basic method of operation and will mean the heater remains switched on, until it is turned off. Please note, to return to programmed user set schedules you will need to select the automatic operation mode by pressing the manual/auto (M/A) select button prior to switching off.
5. Specifications AC500T AC1000T AC1500T AC2000T Supply 230V AC 50Hz Power (half/full) 250/500W 500/1000W 750/1500W 1000/2000W Water resistance IP24 Class Weight 3.4kg 3.4kg 4.7kg 5.2kg Thermal protection Auto reset thermostat x 2 Size (w x d x h) 460x90x 460x90x 595x90x 830x90x 400mm...
Page 12
Model Identifiers: Accona panel heaters AC500T,AC1000T,AC1500T & AC2000T Item Symbol Value Unit AC500T AC1000T AC1500T A2000T Heat output Nominal heat output Pnom Minimal heat output Pmin 0.25 0.75 (indicative) Maximum continuous Pmax, c heat output Auxiliary electricity consumption At nominal heat...
Page 13
Item Unit Type of heat input, for electric storage local space heaters (select one) manual heat charge control with integrated thermostat manual heat charge control with room and/or outdoor temperature feedback electronic heat charge control with room and/or outdoor temperature feedback fan assisted heat output Type of heat output/room temperature control (select one) single stage heat output and no room temperature control...
6. Troubleshooting Error codes and their meaning E1 – Temperature sensor error E3 – Overheat event In the case of an E3 Overheat event the heater will beep until any button is pressed to clear the fault. The cause of the overheat should be investigated before continuing to use the heater.
7. Guarantee and service policy This product is covered by a standard parts or replacement warranty for a period of 12 months from the date of purchase. If there is a manufacturing defect within the warranty period we will send spare parts, repair and return the unit or, at our discretion, supply a replacement product.
Page 16
In order to underline the duty to dispose of this equipment separately, the product is marked with a crossed out dustbin. Hyco Manufacturing Ltd Normandy Court Express Way...