Additional advice LED shines LED flashes Green Blue Orange Violet Abbreviations: BTH Blum Tool Holder Tightening Torque Low Force 1. Safety rules CAUTION Important advice for appliance protection: • Handle probe like a precision tool. • Keep the probe clean.
(10) Fig. 2.1 see chap.3.8 2.2 Display elements Colour LED Status (7) Standby Stylus initial position GN GN Stylus deflected Stylus initial position - battery low Stylus deflected - battery low Battery low Fig. 2.2 by Blum-Novotest 2012...
Page 7
System overview TC60 TC61 TC63-30 Ø63 Ø63 Ø63 Ø28 Ø28 Ø28 TC63-30 TC76-T Ø25 TC64-10 TC62 TC63-10 Ø40 Ø40 Ø40 Ø13 Ø13 Ø13 TC63-10 TC76-T Ø25 Ø25 Fig. 2.3 * trigger point TC61: see data sheet by Blum-Novotest 2012...
Tool holder HSK–SK-BT Operating temperature +5 °C ... +50 °C Storage temperature -20 °C ... +70 °C via spindle orientation Stylus L=50 mm see chap. 3.5 with accessories (e.g. extension, angle): max. acceleration 10 m/s Tab. 2.3 by Blum-Novotest 2012...
Page 11
Tool holder HSK–SK-BT BTH 25 Operating temperature +5 °C ... +50 °C Storage temperature -20 °C ... +70 °C stylus L=30 mm see chap. 3.5 with accessories (e.g. extension, angle): max. acceleration 10 m/s Tab. 2.4 by Blum-Novotest 2012...
Page 12
Max. deflection X/Y (mm) (mm) TC60 TC61 TC62 TC62 T TC63-10/TC76 TC63-30/TC76 TC62 LF TC64-10 TC64-10 T Tab. 2.5 Measuring force X/Y: Stylus Measuring force X/Y (N) length TC60 TC61 TC62 TC63-10/TC76 (mm) TC63-30/TC76 TC64-10 Tab. 2.6 by Blum-Novotest 2012...
Dispose batteries acc. to legal requirements. CAUTION Destruction of the measuring system Be careful to correct position of gasket. Keep battery space absolutely clean and dry. Grease gasket surface of the cover slightly before insert. by Blum-Novotest 2012...
Page 16
Clean and dry battery case carefully with absorptive paper Insert new batteries – take care of polarity! Install battery cover straight (check O-Ring and grease if necessary) Automatic display of the basic adjustments (chap. 3.6 Fig. 3.1 by Blum-Novotest 2012...
Mounting and commissioning 3.3 Mounting of the TC76-T TC63-10/TC63-30: = 10 Nm Fig. 3.3 hook wrench (scope of delivery) Mounting of the extension / angle: see referring data sheet by Blum-Novotest 2012...
• Damaged styli are not reusable! 1,5 mm = 1 Nm TC60 TC61 TC62 TC63-10 TC64-10 TC63-30 Fig. 3.4 interlocking disk (scope of delivery) mounting tool (scope of delivery) Adjustment stylus TC61: see fig. 3.5 by Blum-Novotest 2012...
Page 21
Mounting and commissioning Adjustment stylus TC61: DIN913 M3 x 3 (4x) ~ 0,5 Nm Fig. 3.5 by Blum-Novotest 2012...
C measurement: area of operation: [mm] [mm] 16,5 P [mm] P [mm] area of operation Z+ measurement: max. overtravel: [mm] 15 20 25 30 35 40 45 50 55 60 65 P [mm] overtravel Fig. 3.7 by Blum-Novotest 2012...
After the display is finished, the probe goes into standby mode. LED Status Fig. 3.8 If the LED Status (7) is flashing red or shining red, pls. check the batteries. See chapt. 6, Trouble shooting. by Blum-Novotest 2012...
Page 24
Transmission mode Normal* Robust (3x MODE – SET) Fast Switch-on time Fast Normal* (3x MODE – SET) Slow Probe type Standard* EcoMode TWIN A TWIN B Battery capacity O.K. (3x MODE – SET) Standby * Standard by Blum-Novotest 2012...
The LED Status (7) is shortly flashing violet to confirm the menu change LED Status After the last menu the basic adjustments are repeated (3x MODE-SET). During the display phase it can be changed again into the programming mode. by Blum-Novotest 2012...
Page 26
EcoMode • setting increases battery life • setting for double spindle TWIN A machines: set first probe to TWIN A set second probe to TWIN B TWIN B Automatic display of the basic adjustments Standby by Blum-Novotest 2012...
Page 27
Not valid resp. reserved combinations are not stored. Please check adjustments after programming (chap.3.6) and list them in the system certificate. Please adapt color code on the probe (see chap.3.8) by Blum-Novotest 2012...
Please, do not use any detergents containing acetone, alcohol, cleaning benzine or solvent! They can damage the transparent ring. Please, do not use any detergents containing abrasive substances (e.g. scouring powder or cleansing milk. They can damage the transparent ring! by Blum-Novotest 2012...
The measuring mechanism is not allowed to be twisted! TC62 / TC62-LF / TC76-LF (Low Force) / TC64-10 LF (Low Force): The bellows is allowed to be exchanged by Blum-Novotest only! 1. Clean probe and remove stylus if necessary (chap.3.4), while using the interlocking disk (A) resp.
Page 31
Maintenance Fig. 5.1 TC60 Fig. 5.2 TC61 Fig. 5.3 TC63-30 / TC76 (10) Measuring mechanism (14) Centering ring (10a) Groove (15) Internal bellows (13) External bellows (16) Front ring by Blum-Novotest 2012...
= Check the following points = Remedy / Workaround Error LED Status undefined LED Status flashes resp LED light unsteady Check batteries Insert new batteries Error LED Status red LED Status shines red Battery empty Insert new batteries by Blum-Novotest 2012...
Page 33
(2) Probe is outside of the transmission range (3) No pairing of the probe on IF59-A2 (1) Insert new batteries (2) Check transmission range between receiver and probe Check adjustment of transmission power (probe and IF59-A2) (3) Check pairing by Blum-Novotest 2012...
Saft Lithium LS14250 (½ AA 3,6V) 1000mAh, 2 pcs required Accessory set for TC60/61 – A3 P03.8000-020.003 3,6V 3,6V Accessory set for TC63-30 – A3 P03.8000-020.004 3,6V 3,6V Accessory set for TC62/63-10 P03.8000-020.011 3,6V 3,6V Accessory set for TC76 P03.8000-020.012 by Blum-Novotest 2012...
Page 35
6 mm P03.8000-010.300.06 Carbide Length Ø 50 mm 1 mm P03.8000-012.050.01 2 mm P03.8000-012.050.02 3 mm P03.8000-012.050.03 4 mm P03.8000-012.050.04 5 mm P03.8000-012.050.05 6 mm P03.8000-012.050.06 100 mm 4 mm P03.8000-012.100.04 5 mm P03.8000-012.100.05 6 mm P03.8000-012.100.06 by Blum-Novotest 2012...
Page 36
P03.8000-022.030.04 5 mm P03.8000-022.030.05 50mm 0,5 mm P03.8000-022.050.005 1 mm P03.8000-022.050.01 2 mm P03.8000-022.050.02 3 mm P03.8000-022.050.03 4 mm P03.8000-022.050.04 5 mm P03.8000-022.050.05 6 mm P03.8000-022.050.06 75 mm 5 mm P03.8000-022.075.05 100 mm 5 mm P03.8000-022.100.05 by Blum-Novotest 2012...
The packing is not allowed to deflect the probe, neither in X/Y- nor in Z- direction. • Tool holder and battery are to be removed before packing. • The probe should be packed shock and pollution protected. by Blum-Novotest 2012...
This equipment complies with IC Canada RF radiation exposure limits set forth for an uncontrolled environment as per RSS-102 Issue 4. The device is complying with standard IEEE 802.15.4a. by Blum-Novotest 2012...
The relevant technical information is compiled acc. to annex VII part B and, where appropriate, we will send the information concerning the components to the different countries. The industrial property rights of Blum-Novotest GmbH will remain unaffected. Component name: P03.6000 / P03.6100/ P03.6200 P06.6300 / P06.6400 / P06.7600 /...