请在使用之前务必阅读使用说明书。 可以从松下电器官方网站下载使用说明书。 industrial.panasonic.com/ac/c/ 本产品为产业用机器。禁止在家庭使用。 Safety Guide Brushless Amplifier MINAS-BL GU series Before operating this product, please be sure to read the Operating Instructions. You can download the Operating Instructions from Panasonic Web Site. industrial.panasonic.com/ac/e/ This product is for industrial use only, and not used in residential areas.
Page 6
A 급 기기 ( 업무용 방송통신기자재 ) 이 기기는 업무용(A 급) 전자파적합기기로서 판매 本ブラシレスアンプは、組み込まれる機械・装置のE C指令への適合を容易にするために、低 자 또는 사용자는 이 점을 주의하시기 바라며 , 가정외의 電圧指令の関連規格適合を実現しております。 지역에서 사용하는 것을 목적으로 합니다 .(대상기종 : BRUSHLESS AMPLIFIER ) ■ CE マーキング EU 代理人 参考和訳 Panasonic Testing Centre A級機器(業務用放送通信機材) Panasonic Marketing Europe GmbH この機器は、業務用電磁波発生機器(Class A)であり、 家庭以外の場所での使用を意図 Winsbergring 15, 22525 Hamburg, Germany しています。 販売者やユーザーはこの点に注意してください。 (対象機器 :BRUSHLESS AMPLIFIER)...
Page 12
A 급 기기 ( 업무용 방송통신기자재 ) 이 기기는 업무용(A 급) 전자파적합기기로서 판매 该无刷放大器实现了与低电压指令的相关标准的符合性,以便于符合要并入的机械设备的 EC 자 또는 사용자는 이 점을 주의하시기 바라며 , 가정외의 指令。 지역에서 사용하는 것을 목적으로 합니다 .(대상기종 : BRUSHLESS AMPLIFIER ) ■ 欧盟地区 CE 认证代表 参考和訳 Panasonic Testing Centre A 类设备(商业广播通信设备) 本设备是一种商用电磁波发生器(A 类) ,旨在用于户外。 Panasonic Marketing Europe GmbH 卖家和用户应该知道这一点。 (适用设备 : BRUSHLESS AMPLIFIER) Winsbergring 15, 22525 Hamburg, Germany 外围设备构成...
Safety Precautions Safety precaution in installation (continued) The following explanations are for things that must be observed in order to prevent Caution harm to people and damage to property. ■ Misuses that could result in harm or damage are shown as follows, classified Do not use the product except for specified combination of Cause of damages, breakage.
Page 16
Safety Precautions Safety precautions during operation Safety precautions in case of abnormality Danger Danger Do not touch the brushless amplifier or brushless motor as it will Cause of electric shock, Cause of burn. Do not use damaged products. be hot. injuries, fire or breakage.
Installation (Amplifier) Contents of Name Plate Amplifier Environmental Conditions Nameplate Item Conditions Example of the nameplate Ambient temperature 0 ˚C to 40 ˚C (free from freezing) Model No. Ambient humidity 20 % to 85 %RH (free from condensation) Serial number BRUSHLESS AMPLIFIER Ex.: P 1 8 0 4 0 0 0 1 *...
Page 18
Wiring Wiring Terminal for power supply (POWER) System configuration/ general wiring diagram Part number of terminal block: 0138-7603 (DINKLE) Motor extension cable (option) Digital key pad connecting cable (option) GU series Terminal Terminal Select if needed (up to 10 m).* Digital key pad (option) Terminal explanation...
Authorised representative for CE marking in the EU ■ should be aware of this fact. Panasonic Testing Centre Panasonic Marketing Europe GmbH Configuration of peripheral equipment Winsbergring 15, 22525 Hamburg, Germany EMC Directives ・ 100 V system: Single phase 100 V to 120 V ± 10 %, 50 Hz/60 Hz Brushless amplifiers are not intended for general home use or connection to low-voltage 200 V system: Single phase 200 V to 240 V ±...
Input voltage Voltmeter Must be within ±10% of rating. industrial.panasonic.com/ac/e/ Input current Ammeter Must be within rated input current described on nameplate. The resistance of motor should be 1 MΩ or higher when tested with a 500 V megger.