C 2-14
Hydraulic Section Repair
16
Figure C 2-13 Hydraulic Section Installation
1. Solvent cup
3. Upper housing
4. Plunger
Part 1102698−07
Installing Hydraulic Section
1. See Figure C 2-13. Install the hydraulic section on the air motor
studs (15). Tighten the hex nuts (16) to 136 ± 14 NSm (100 ± 10 ft-lb).
2. Secure the upper housing (3) to the pump mounting surface.
3. Tighten the entire hydraulic section using the large hex nut on the
siphon housing. Tighten securely.
Tighten to 136 ± 14 NSm
(100 ± 10 ft-lb).
15
3
Customer-supplied
fasteners
15. Air motor studs
16. Hex nuts
18
17
4
1
17. Connecting rod
18. Coupling sleeve