4. Locate the Ethernet output pivot connectors inside the CM-150 CA housing.
Open both pivot connectors.
5. Following the wire color codes printed on the data board, insert the Orange/
White, Orange, Green/White, and Green wires into the pivot connector's wire
entry holes.
6. While holding the wires firmly in place, push down on the pivot connectors until
they click shut.
7. Run the free end of the cable to the next CM-150 CA device in the series, and
make Ethernet data input connections as described in the previous section.
8. Repeat for each CM-150 CA device in the series.
Series Connection Using DMX
1. Cut a sufficient length of Cat. 5e cable to connect the first CM-150 CA device in a
series with the next.
2. If necessary, cut both ends of the cable jacket to expose the wire pairs. Do not
strip the wire pairs. The Brown, Brown/White, Blue, and Blue/White wires are
not used and should be capped and turned back.
4. Locate the DMX output pivot connectors inside the CM-150 CA housing. Open
both pivot connectors.
5. Following the wire color codes printed on the data board, insert the Orange/
White, Orange, Green/White, and Green wires into the pivot connector's wire
entry holes.
6. While holding the wires firmly in place, push down on the pivot connectors until
they click shut.
7. Run the free end of the cable to the next CM-150 CA device in the series, and
make DMX data input connections as described in the previous section.
8. Repeat for each CM-150 CA device in the series.
9. If installing the last CM-150 CA control module in a DMX run, terminate the end
of the DMX run using the supplied pin jumper.
Ethernet input
Ethernet output
(optional)
DMX input
DMX output
(optional)
Not terminated
Terminated
13