Halsey Taylor HydroBoost HTHB-HAC Installation And Use Manual

Halsey Taylor HydroBoost HTHB-HAC Installation And Use Manual

Retrofit hydroboost bottle filling station

Advertisement

Installation and Use Manual
Retrofit Hydroboost
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING STATION AND WATER
COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).

INSTALLER

HTHB-HAC Bottle Fillers are among the easiest to install on the market today.
To insure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR
INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER
APPLICABLE CODES. After installation, leave these instructions with the Fountain
for future reference.
HAC-HB*1C
HTHB-HAC
IMPORTANT! INSTALLER PLEASE NOTE.
HAC-HB-NF-*1C
Bottle Filling Station
®
IMPORTANT
THIS IS AN INDOOR APPLICATION ONLY.
ALL SERVICE TO BE PERFORMED BY AN
AUTHORIZED SERVICE PERSON.
TOOLS REQUIRED
BUT NOT PROVIDED:
SAFETY GLASSES
GLOVES
ELECTRIC DRILL
3/4" WRENCH OR CRECENT
WRENCH
UTILITY KNIFE
TAPE MEASURE
PENCIL
5/32" ALLEN WRENCH
Page 1
1000004727 (Rev. A - 09/18)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HydroBoost HTHB-HAC and is the answer not in the manual?

Questions and answers

Summary of Contents for Halsey Taylor HydroBoost HTHB-HAC

  • Page 1 HAC-HB*1C HAC-HB-NF-*1C Installation and Use Manual HTHB-HAC Retrofit Hydroboost Bottle Filling Station ® IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON. TOOLS REQUIRED BUT NOT PROVIDED: SAFETY GLASSES GLOVES ELECTRIC DRILL 3/4”...
  • Page 2 HAC-HB*1C HAC-HB-NF-*1C WATER COOLER PREPARATION NOTE: • On Two Level Models, the Bottle Filling Unit can be mounted to the higher or lower unit: • Two Level Standard Models; high unit is on Left Hand(LH) side. • Two Level Reverse Models; high unit is on Right Hand(RH) side. 1) Remove Front Panel •...
  • Page 3 HAC-HB*1C HAC-HB-NF-*1C WATER COOLER PREPARATION 5) Lift and Remove Basin. • Remove basin assembly by lifting straight up, disconnecting the drain line from the P-trap. Lift and Remove Basin. 6) Assemble Drain hardware. • Remove drain hardware from original basin. •...
  • Page 4 HAC-HB*1C HAC-HB-NF-*1C HWF3000 WATERSENTRY PLUS FILTER INSTALLATION (With Filter) ® WARNINGS: • Do not use with water that is microbiologically unsafe or of unknown quality. For potable water only. • Do not use with a hot water supply. Rated for water temperature: 33°-100°F(2°-38°C) • Water line pressure must not exceed 100 PSI(690kPa). Use an inline water pressure regulator before filter to limit maximum pressure.
  • Page 5 HAC-HB*1C HAC-HB-NF-*1C HWF3000 WATERSENTRY PLUS FILTER INSTALLATION (With Filter) ® 3) Mount Filter Head Assembly Mount Filter Head Assembly into Cooler. Unit with single supplied screw: • Single Level Models • Mount on inside of left panel butted up against top lip. • NOTE: The filter bracket is mounted with a single screw.
  • Page 6 RE-PLUMBING SINGLE STATION WATER CIRCUITS (NON-FILTER) CAUTION: • This procedure MUST be performed on ALL SINGLE HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly! • When disconnecting water lines use a container to catch any water running out of the lines.
  • Page 7 RE-PLUMBING SINGLE STATION WATER CIRCUITS (WITH FILTER) CAUTION: • This procedure MUST be performed on ALL SINGLE HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly! • When disconnecting water lines use a container to catch any water running out of the lines.
  • Page 8 RE-PLUMBING TWO LEVEL STATION WATER CIRCUITS (NON-FILTER) CAUTION: • This procedure MUST be performed on ALL TWO LEVEL HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly! • When disconnecting water lines use a container to catch any water running out of the lines.
  • Page 9 RE-PLUMBING TWO LEVEL STATION WATER CIRCUITS (WITH FILTER) CAUTION: • This procedure MUST be performed on ALL TWO LEVEL HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly! • When disconnecting water lines use a container to catch any water running out of the lines.
  • Page 10 HAC-HB*1C HAC-HB-NF-*1C BASIN ASSEMBLY PREPARATION 1) Connect Water Line • Connect water line from Regulator to Bubbler. Connect Water Line 2) Install New Basin Assembly • Reposition Basin Assembly (Basin with Drain and Bubbler hardware) back onto the cooler. • Reattach drain line to P-trap and tighten.
  • Page 11 HAC-HB*1C HAC-HB-NF-*1C BOTTLE FILLER INSTALLATION 7/16” BOLT HOLES FOR MOUNTING FASTENING UNIT TO WALL TOP COVER SCREWS UNIT CENTER LINE WALL MOUNTING BOTTLE FILLING PLATE UNIT Fig. 7 Fig. 6 Fig. 8 BOTTLE FILLER INSTALLATION 1) Remove two (2) mounting screws with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 6 - above). Remove top cover. Note do not discard mounting screws, they will be needed to reinstall top cover.
  • Page 12 HAC-HB*1C HAC-HB-NF-*1C BOTTLE FILLER GASKET Fig. 9 Fig. 10 1000004727 (Rev. A - 09/18) Page 12...
  • Page 13 HAC-HB*1C HAC-HB-NF-*1C BF11 - BF12 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE Continued from below: 1) To verify the software program of the control board the unit will 2) When the display changes to “SETTINGS”, depress the button again. need to be shut down and restarted.
  • Page 14 HAC-HB*1C HAC-HB-NF-*1C RESET FIVE PIN BUTTON CONNECTOR PIGGY BACK MAIN BOARD FOUR PIN TERMINAL ON CONNECTOR POWERCORD WHITE I.R. BOARD SOLENOID LED BOARD (For Filtered Models) VIOLET YELLOW PROTECTIVE GREEN GROUND (NOT USED) CONNECTOR WIRING DIAGRAM NEUTRAL FROM POWER 120 VOLT WHITE CORD SINGLE &...

Table of Contents

Save PDF