July 2013
Module 9161 Enable the drive controller
With this module you can switch the drive controllers (speed and current
controllers) on and off for specific axes. A nominal speed value is also output
when the drive controller is not enabled.
The switch-on time for switching on a drive via PLC module 9161 is less than
50 ms. In individual cases this results in problems. You can deactivate the
reduction of the switch-on time with bit 7 of MP2221.x.
Call:
PS
W/D/K
<Enabled axes>
Axis-specific: Dependence on MP4020 bit 14
0: No drive controller enabling
1: Drive controller enabling
CM
9161
Error code:
Marker
Value
Meaning
M4203
0
No error
1
Control has no current controller, or the call is in a
spawn or submit job
Module 9162 Status request of the drive controller
Call:
CM
9162
PL
B/W/D
<Drive is ready>
Axis-specific: Dependence on MP4020 bit 14
0: Not ready
1: Ready
Module 9169 Axes for which I32 does not switch off the drives
Call:
PS
B/W/D/K <Axes bit-encoded>
Axis-specific: Dependence on MP4020 bit 14
CM
9169
M4563
Global feed-rate enable for all axes
6.8 The control loop
Set
Reset
PLC
PLC
865
Need help?
Do you have a question about the iTNC 530 HSCI and is the answer not in the manual?