FOR REVERSE OSMOSIS SYSTEMS
MODEL | ET6500 (P/N 10-02-1330)
Includes: Installation and Service Procedures, Specifications and Operation Guidelines
A
07\15 RO Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ET6500 and is the answer not in the manual?

Questions and answers

Summary of Contents for AmeriFlow Water Systems Inc. ET6500

  • Page 1 Owners Manual FOR REVERSE OSMOSIS SYSTEMS MODEL | ET6500 (P/N 10-02-1330) Includes: Installation and Service Procedures, Specifications and Operation Guidelines 07\15 RO Manual...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction Uses and Benefits Specification Limitations Warnings Photo of ROs and Contents List Installation Procedures System Position Faucet Installation Figure 1 Diagram Easy Tap Adapter Installation Drain Saddle Clamp Installation Figure 2 Diagram Storage Tank Preparation Tubing Connections System Start-Up Procedures Refrigerator Icemaker Hookup Recommended Filter Service Life...
  • Page 3: Uses And Benefits

    IMPORTANT: ONLY USE ON POTABLE WATER SUPPLIES Obtain all materials and tools needed for installation before starting. Please read entire manual carefully before proceed- ing with installation. Failure to follow manual’s guidelines could cause personal injury or property damage. Be sure to check household plumbing for signs of leaks, corrosion and aging.
  • Page 4: Warnings

    SYSTEM: System Dimensions 16”×15.5”×7” Storage Tank Dimension 15.5”×11” Rejection Rate Up to 98% TDS * Storage Capacity Up to 3.2 Gallons* Production Capacity Membrane Rating 24 gallons per day * *NOTE: These specifications are not the certified results and can vary greatly depending on feed water makeup, i.e.
  • Page 5: Photo Of Ros And Contents List

    PHOTOS OF RO AND CONTENTS LIST 1. Faucet and tubing 5. Union Coupling 8. FilterPac Unit 2. Drain clamp 6. R/O tubing 9. Re-Min module attached to top of FilterPac 3. Easy Tap Adapter 7. Storage tank with ball valve 10.
  • Page 6: Easy Tap Adapter Installation

    FIGURE 1 for your type of sink. Place an old towel under the sink to catch any metal filings and to make clean up easy. After drilling, clean up metal filings quickly to avoid staining the porcelain. 2. Install Air-gap Faucet Pre-assemble faucet prior to installing on the sink.
  • Page 7: Storage Tank Preparation

    FIGURE 2 Red line connects to RO drain line Faucet supply from RO system NO DIPS in LINE as possible and that there are no dips, loops, low spots or kinks. (See D in Figure 2 above). Also, to reduce noise, assure that RO drain line enters the vertical pipe from a direction other than the direction of entry of the garbage disposal pipe.
  • Page 8: System Start-Up Procedures

    3. 3/8” black Drain Tube from Faucet Connect this tube to the black 3/8” drain clamp. (See D in Figure 2 on page 6). Tighten firmly so tube will not pull out of drain clamp. IMPOR- TANT: Do not leave excessive slack in drain tubing. Shorten tubing so that it flows directly to the drain with no dips, loops, low spots, or kinks.
  • Page 9: Filter Replacement List

    Other filters may not have the same capacity as original factory filters and may not last as long. Water conditions vary greatly by region and can affect filter change intervals. For filter change interval recommendations, follow the guidelines below. If in doubt, contact the manufacturer. Sediment Pre-filter These are the only filter(s) that you can visually inspect.
  • Page 10: Filter Change Instructions

    STEP 10 FILTER CHANGE INSTRUCTIONS 1. Sediment and Carbon Turn Filter Pac/RO module ball valve to off position. Turn tank ball valve off. Turn on RO faucet to help de-pressurize system. Unscrew filter bowls by turning counter-clockwise. Remove old filters and discard. Clean filter bowls if needed in warm, soapy water.
  • Page 11: Ro Schematic

    RO SCHEMATIC RO WATER WT= White FAUCET BK6= 3/8” Black BL= Blue REMIN BL6= 3/8” Blue RD= Red CARBON FILTER RO MEMBRANE HOUSING WATER CONSERVATION SHUT-OFF DRAIN EASY SEDIMENT CARBON A.A.C.T. RO WATER FILTER FILTER STORAGE TANK REPLACEMENT PARTS LIST QUANTITY PART NO.
  • Page 12: Troubleshooting Guide

    REPLACEMENT PARTS LIST 805-25-04 Faucet Adapter 3/8” × 7/16” fpt 805-15-04 ¼” Union JG 124-462 Drain Saddle Clamp 127-1101 Filter Bowl Canister 127-1R O-ring, Filter Bowl canister 805-LC-06 3/8” Locking Clip JG 805-LC-04 ¼” Locking Clip JG 122-321 Clips, Membrane 2 (4)* 122-24321 Clips, Post Filter *(ET6000)
  • Page 13 Water does not Bad membrane. Replace membrane when below 75% rejection and taste or smell sanitize. right. Filters have expired. Replace filters. Should be replaced every 6 to 12 months. Little water use. Drain or use entire tank. Should be done every 2 weeks if low water use.
  • Page 14: Performance Data Sheet

    PERFORMANCE DATA SHEET REVERSE OSMOSIS SYSTEM MODEL NUMBERS 1-1310-10, 1-1320-10 REPLACEMENT TREATMENT COMPONENTS SEE STEP 9, PAGE 8 GENERAL INSTALLATION — OPERATION — MAINTENANCE REQUIREMENTS • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before of after the system.
  • Page 15: Manufacturers Warranty

    MANUFACTURER’S WARRANTY REVERSE OSMOSIS / FILTRATION LIMITED WARRANTY Your Reverse Osmosis / Filtration system is warranted to the original owner from date of pur- chase as indicated below. Factory labor to repair or replace defective component(s) covered by warranty for: Multiplex MasterFlow™...
  • Page 16: Warranty Registration Card

    WARRANTY REGISTRATION CARD Mail form and a copy of original sales receipt to: AmeriFlow™ Water Systems Inc. 525 21st St. Tempe, AZ 85282 U.S.A., (602) 275•4188. Or Fax form and a copy of original sales receipt to: (602) 244•2505 AmeriFlow™ Water Systems Inc. considers the safety of your personal information very important.