  • Page 1 Combi D 6 (Australia) Operating instructions Page 2 To be kept in the vehicle! Combi ° ° Comfort on the move...
  • Page 2: Function Description

    Combi D 6 (Australia) 1 Control panel 2 Time switch ZUCB (Accessories) 3 Room temperature sensor 4 Cold water connection 5 Hot water connection 6 Fuel connection 7 Hot air outlets 8 Recirculated air intake 9 Waste gas discharge 10 Exhaust air flue...
  • Page 3: Safety Instructions

    – modifications to the unit (including accessories), and odours. – modifications to the exhaust duct and the cowl, – failure to use original Truma parts as A diesel heating system always needs more power than a replacement parts and accessories, similar gas heating system.
  • Page 4: Operating Instructions

    2 start attempts (initial start and repeat) per switch- all users (e.g. on the wardrobe door)! Ask Truma to send you on procedure with a run time of 2 minutes in each case. If no stickers, if necessary.
  • Page 5: Switching Off

    If the green LED (b) blinks after switching off, then the unit‘s after-running is active in order to reduce the unit‘s temperature. This will end after a few minutes and the green Only original Truma parts may be used for maintenance and LED (b) will go off. repair work.
  • Page 6: Technical Data

    Fuses Technical data found by Truma Test conditions The fuses are located in the electronic control unit, beneath the connector cover. When replacing a fuse, be sure to use Fuel the same type. Fuel, as per the Australian Fuel Standard (Automotive Diesel).
  • Page 7: Troubleshooting List

    Trouble-shooting list Flash code on the control panel Flash sequence LED: – On: 0.5 seconds – Off: 0.5 seconds Pause between the flashing sequence: 3 seconds Fault Cause Rectification After switching on – No operating voltage. – Check 12 V battery voltage, charge if necessary. (winter and summer opera- tion) none of the LEDs are lit.
  • Page 8 Fault Cause Rectification Water supply Water running out, cannot – Safety/drain valve open. – Close safety/drain valve. fill boiler. Cannot empty boiler, even – Safety/drain valve draining – Check opening for soiling (slush, ice, leaves etc.) and though safety/drain valve is connection blocked.
  • Page 9: Truma Warranty Policy

    – The company will only provide service on presentation grey colour, for every control panel / every time switch. of proof of purchase, on either the Truma product, or the Caravan / RV / Pleasure Craft in which the Truma product Line-up clip, 1 unit (part no.
  • Page 11 Combi D 6 (Australia)
  • Page 12 In Australia, always notify the Dometic Service Centre if problems are encountered; in other countries the relevant service partners should be contacted (see Service Booklet or www.truma.com). Having the equipment model and the serial number ready (see type plate) will speed up processing.