15. Available functions at turn-on

You can check operations of the TD-260T when turning it on.

15-1. Performing self-check

This function allows the TD-260T to perform a self-diagnostic
check of LEDs, RAM, SRAM, EEPROM, and TEDS, in this order.
1. While pressing and holding ESC, turn the TD-260T on.
2. The TD-260T displays sets of the same numbers, such
as 88888, to check LEDs, one after another.
3. The TD-260T displays the following message during
the internal RAM check process.
4. The TD-260T displays the following message during
the external SRAM check process.
5. The TD-260T displays the following message during
the EEPROM check process.
72
Turn the TD-260T on
while holding:
6. The TD-260T displays the following message during
the TEDS check process.
7. The TD-260T displays a reading after all the check
processes are completed.
NOTE
The TD-260T displays one of the following messages when
an error is detected: cErr0, cErr1, cErr2, and cErr3.
If you encounter any one of the errors, shut off the power to
the TD-260T, and then, while pressing and holding ESC, turn
it on again to perform a self-check. If the error continues to
occur, see the last page of this document and contact us.

15-2. Initializing settings

You can initialize settings all at once to restore the factory
preset values.
1. While pressing and holding ESC and ENTER, turn the
TD-260T on.
After the settings have been initialized, a self-check starts.
NOTE
Calibration values are not initialized.
Turn the TD-260T on