NANOVIP PLUS MEM
Supplemento al manuale di istruzione Nanovip Plus • Supplement to Nanovip Plus manual
• Supplement au manuel d'instruction Nanovip Plus • Ergänzung zum bedienungshandbuch
Nanovip Plus • Suplemento al manual de instrucciones Nanovip Plus

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NanoVIP Plus Mem and is the answer not in the manual?

Questions and answers

Summary of Contents for Elcontrol NanoVIP Plus Mem

  • Page 1 NANOVIP PLUS MEM Supplemento al manuale di istruzione Nanovip Plus •...
  • Page 2 NANOVIP PLUS MEM SUPPLEMENT TO NANOVIP PLUS MANUAL...
  • Page 3 INDEX The new functions on the NANOVIP PLUS MEM Management of Harmonics Autoscroll. with respect to the NANOVIP PLUS model are ............page 28 the following: g) New Modbus command for setting a determined Harmonic..........page 28 a) Recording of campaigns of automatic measures in an internal serial memory of 8 Megabits h) Input for external DC feeder (6 VDC, 150 mA).
  • Page 4 A) RECORDING OF MEASURE CAMPAIGNS In the LOG CTRL MENU the recording of the B) DISPLAY BACKLIGHTING (operation) measure campaigns can be activated or deactivated; this menu also displays the percentage recorded in The SETUP MENU is added with a Setup page on This function allows you to store in a special flash- memory and the programmed rate of recording.
  • Page 5 E) DOWNLOADING OF VOLTAGE AND CURRENT WAVEFORM D13= lsb zero corresponding to samplings of second frame (Current) D14= msb zero corresponding to samplings of second frame (Current) The format of the string transmitted by NANOVIP PLUS containing 200 waveform samples is as follows: D15= lsb calibration factor relative to second frame (Current) E:0103 D1 D2D3D4 D5D6 D7D8D9 V1..V200 D10D11D12 D13D14 D15D16D17 I1..I200 CS CRLF D16= msb calibration factor relative to second frame (Current)
  • Page 6 F) AUTOSCROLL MANAGEMENT G) MODBUS COMMAND FOR SETTING A just from this Harmonic, goes on increasing the DETERMINED HARMONIC index. During activation of the measures LOG(storage), the Autoscroll of the harmonic displayed, when The NANOVIP PLUS includes a Modbus command enabled, increases the harmonic index at each that allows you to set the immediate calculation of H) SOCKET FOR EXTERNAL DC FEEDER...
  • Page 7 If LOG “ON”, jump to Setup Display k 9.6 From 15’ SETUP HARM SETUP PT SEL + SET SEL + SET SEL + SET SEL + SET 00 = 2 Seconds 01-99 minutes Data recording rate Clear • Backlit OFF Restore data •...
  • Page 8 To MEAS MENU PAGE To MEAS PAGE Volt 36.0 Volt 36.0 From THD I To Crest Factor V 10.0 10.0 Harmonic CosF 0.50 CosF Is displayed SEL + SET Clock Calendar SET=SCROLL/STOP 36.0 Volt Data recording OFF of memory used 2.07 Data recording rate Harmonic KW...
  • Page 9 NANOVIP PLUS MEM: Where: • MEM measures: • PEAK measures: INTERNAL MEMORY STRUCTURE - YY, MM, DD, HH, MM are the year, month, day, - Storage medium utilized: 0Serial Flash Memory hour and minute when the record was recorded YY MM GG HH MM 0x02 24 Byte record data SS Check YY MM GG HH MM 0x02 24 Byte record data SS Check type NX25F080 (NEXCOM);...
  • Page 10 • THD + DC Ripple + HARMONIC measures: - 0x14 is the type of record: record 4, under record 1 (D6); Through the Setup menu (LOG SETUP) the data recording mode can be configured: - Record data: - VDC Ripple (D7..D9: base + exp) - LOG_RATE - Setup of measures sampling time;...
  • Page 11 Given that the test on the reception of a Modbus + cr lf it necessary to assign the reading command with command by the NANOVIP PLUS MEM takes place a range of virtual addresses that would simulate when the calculation is finished, there would be the - nn represents the number of words transmitted the data request from memory;...