Start on the PC via Ethernet Operating Instructions For the service software variants of IRMA-MATRIX-Configuration IRMA-MATRIX-Visualization IRMA-TestRide-IRMA MATRIX iris-GmbH | Ostendstrasse 1 – 14 | 12459 Berlin | Germany Rev. 1.2 | 2016-02 www.irisgmbh.de Subject to alterations!
Page 2
2/15 Starting IRMA MATRIX on the PC via Ethernet released Document information Title of document: Starting IRMA MATRIX on the PC via Ethernet Revision: Edition (YYYY-MM): 2016-02 Type of document: Customer documentation Status: released Document history Rev. Date Name Comments/modifications 24.02.2016...
Select Internet protocol type 4(TCP/IPv4), right: Enter IP address ......7 Figure 2: How to enter the extended PCP/IP settings ..............8 Figure 3: Entering the IP address for IRMA MATRIX as a second entry ........9 Figure 4: PC connection with sCON-S-CAN-ETH-23-Kq-x-y standard ......... 11 Figure 5: PC connection with sCON-S-ETH-22-Kq-x-y .............
Name of a window or button Brief description These instructions describe the steps required for connecting an IRMA MATRIX sensor to any PC. Afterwards, a suitable software program enables for example the check of the condition on delivery, configuration of the sensor properties, updating of the firmware or viewing of the sensor graphic data.
• IRMA TestRide, IRMA MATRIX (for signal recording on test rides) What is required for connecting an IRMA MATRIX sensor to the PC: 1. 24 V power block M12 with M12 connecting cable: M12 connector (f, 5 poles, A coded).
6/15 Starting IRMA MATRIX on the PC via Ethernet released Overview of the necessary steps of work 1. Downloading the software to your PC 2. Checking the settings in the network architecture 3. Setting the IP address for your PC 4.
7/15 Starting IRMA MATRIX on the PC via Ethernet released Changing (setting) the IP address of your PC network adapter Select or open the following windows one after the other: "Control Panel"\"Network Settings" \"Local Area Connection"\"Properties"\"Internet Protocol (TCP/IP)" Windows XP: \"Properties"...
8/15 Starting IRMA MATRIX on the PC via Ethernet released 3. Then the items of the IP address can be activated for entry by a mouse-click. The following entries are possible: IP address: 10.0.0.x with x = 11 – 249 The first 10 IP addresses are mostly reserved for other services.
• Conclude the entry of the IP address by clicking "Add", it will appear as the second entry (see Figure 2 on the right). Figure 3: Entering the IP address for IRMA MATRIX as a second entry Rev. 1.2 2016-02...
10/15 Starting IRMA MATRIX on the PC via Ethernet released Switching off the WLAN In order to prevent communication problems, absolutely switch off the WLAN! • If available, please switch off the WLAN hardware switch on the PC • deactivate the WLAN symbol in the status bar or •...
PC connection with a standard connector of the type sCON-S-CAN-ETH-23-Kq-x-y 1. Connect the IRMA MATRIX sensor with the connector. See Figure 4. 2. Connect the Ethernet interface of the sensor (M12 female connector, 4 poles) to the M12 connector (male, 4 poles), using an adapter cable (see Figure 4 with item (4) or (5)).
12/15 Starting IRMA MATRIX on the PC via Ethernet released PC connection with a standard connector of the sCON-S-ETH-22-Kq-x-y type This sCON is installed in vehicles fitted with a switch. On installation the sensor power supply is connected as specified in the installation instructions. Connect the PC to the switch using suitable cables, see Figure 5, item 5.
13/15 Starting IRMA MATRIX on the PC via Ethernet released Starting the service software Before the first run of the service software program In order to prevent communication problems, the communication path is determined for all service software variants. Before the first run of a service software tool please proceed as follows: 1.
14/15 Starting IRMA MATRIX on the PC via Ethernet released Important at each start of the software Always switch the sensor on first via the switch on the PC. Then activate the power supply. In some cases a sensor RESET may be necessary. For this purpose disconnect the sensor from its power supply for a period of approx.
15/15 Starting IRMA MATRIX on the PC via Ethernet released Restoring the initial state at the PC On conclusion of the work with the sensor on the PC the modified settings for the network adapter must be reset. This can be omitted only if the IP address of the sensors was made as a second IP entry.