CONFIGURATION
7.16.2

Factory settings

7.16.3

Managing passwords

100
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
Restarting safety function and connections
The device's function is also re-established after serious faults if the cause has
been rectified
Communication with the device is interrupted (connections for configuration,
safety function and data not relating to safety). The device sets up communication
again automatically after restarting.
Communication beyond the device is not impaired
Restarting device completely
The device behaves exactly as it does when the voltage supply is switched off and
back on again.
The device's function is also re-established after serious faults if the cause has
been rectified
Communication with the device is interrupted (connections for configuration,
safety function and data not relating to safety)
Communication beyond the device is interrupted. This may also affect devices
which communicate beyond the device.
Before reconfiguring the device, you can reset all settings to factory settings.
Reseting safety function to factory settings
The configuration for the safety function is reset to factory settings
Communication beyond the device is not impaired
Reseting whole device to factory settings
The configuration for the safety function is reset to factory settings
The configuration of device communication is reset to factory settings (connec‐
tions for configuration, safety function and data not relating to safety)
Assigning or changing passwords
1.
Establish a connection to the device.
2.
In the device window, under Service, choose the entry User password.
3.
Choose the user group in the User password dialog box.
4.
Enter the new password twice and use Accept to confirm.
5.
If you are requested to log in, log in as an Authorized customer.
The new password is valid for the user group immediately.
Resetting a password
If you have forgotten a password, you can reset it.
1.
Request the form for resetting your password from SICK support.
2.
Connect to the device in Safety Designer.
3.
In the device window, under Service, choose the entry User password.
4.
Choose the Reset password option in the User password dialog box.
5.
Transmit the serial number shown and the device counter together with the prod‐
uct number and the type code on the form to SICK support.
You will then receive a reset code.
6.
Enter the reset code under Password reset and use Accept to confirm.
The passwords are reset to factory settings (SICKSAFE for an authorized client, no
password for machine operators. It is not possible for maintenance technicians to log
in). The configuration is not changed.
8017784/11JR/2018-10-25 | SICK
Subject to change without notice