(This guide was extracted and modified from the Installation Guide for the PID Retrofitting
Kit for Rancilio Silvia. Full instruction will be provided to the kit buyer)
Procedure

Installation in boiler compartment

Fig 1, top view of original wiring. Red arrows indicate where the controller power cable
will be tapped. Green arrow points to brew water control thermostat. Blue arrow points
to steam temperature control thermostat.
1) There are two thermostats on top of the boiler. The one on the left with a red dot on top is
the brew water temperature control thermostat. The one on the right is for controlling the
steaming temperature. You need to remove the cable connectors on both side of brew
water temperature thermostat (connectors with red and gray cable). They need to be
connected to the output cable of SSR (after the RTD sensor installation). You also need
to remove this thermostat and move the steaming thermostat to its position. This is
because you need to mount the RTD sensor to the thermowell underneath the steam
temperature control thermostat. This thermowell is closer to the cold water inlet, and
results in better control. You need to use a small to medium sized flat head screw driver
to remove the screw. Be very careful to not let it drop into the gap below. A magnetized
PT100M Installation Guide
Version 1.0
e-mail:
auberins@gmail.com
www.auberins.com
Tel: 404-291-6298

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PT100M and is the answer not in the manual?

Questions and answers

Summary of Contents for Auber PT100M

  • Page 1 PT100M Installation Guide Version 1.0 Auber Instruments, 730 Culworth Manor, Alpharetta, GA 30022 e-mail: auberins@gmail.com Tel: 404-291-6298 www.auberins.com (This guide was extracted and modified from the Installation Guide for the PID Retrofitting Kit for Rancilio Silvia. Full instruction will be provided to the kit buyer)
  • Page 2 screw driver will help. Fig 2 shows the steam thermostat has been relocated and thermowell for RTD sensor is exposed (marked with red arrow). Fig 2, Thermowell for RTD mounting 2) Install the RTD sensor. Caution: the connection between the RTD and cable is very fragile because of the small size and there is no strain relieve.
  • Page 3 45 minutes or longer. Since SV can be easily changed, it will up to the user to decide what the best temperature is for the espresso. Recommend PID Parameters with PT100M sensor. For the current model of SYL-1512, you can try the following setting.

Table of Contents