Intended Use: SiLL-Ha is an oral health assessment instrument, providing
information to assess gum health, tooth health and oral cleanliness. The
instrument uses oral rinse (saliva) samples from individuals to perform this
assessment. The instrument is not intended for diagnosis. It is to be used
by dental health care professionals (such as dentist, hygienist, etc.) to help
with patient education on oral wellness.
START
PC
1
SH
2
ON
Open the software on PC.
Press and hold power
button on SiLL-Ha to start.
SAMPLE
Pour
6
Pour the oral rinse solution into
a cup.
TEST
10
Procedure screen.
Follow steps 1 - 5
to complete test.
10
Ammonia pad
2
Remove excess sample
from strip as shown being
careful to not touch the
ammonia pad.
PC
SH
3
Click [Test] to show
patient information.
10
Swish
7
Ask patient to swish for
10 seconds and spit into cup.
SH
20
Spacer
3
After the long beep, lay
test strip flat on surface and
slowly peel off the spacer
over the ammonia pad.
Quick Reference Guide
PC
4
Enter patient information and chart
number. Tap [OK] when complete to send.
Aspirate
8
Aspirate the sample with the
dropper.
10
4
Place the test strip in holder
as shown, and close cover.
Refer to SiLL-Ha Operating Manual for
complete instructions for use, warnings
and cautions. For Customer or Technical
Service, please call: 844.559.0842.
Caution: Patients should be advised to
NOT drink, eat or brush their teeth two
hours prior to the testing for best results.
Indicates a timed step in seconds.
PC
Indicates action performed on PC.
SH
Indicates action performed on SiLL-Ha.
SH
Chart No.
5
Verify Chart No. on standby screen.
9
Drop sample on each pad of test
strip, beginning with yellow pad.
7
260
The test will begin and takes 260 seconds. When
complete, open the cover, remove the test strip and
discard. Close cover.
Standby
Drop
1
(OVER)

Advertisement

loading
Need help?

Need help?

Do you have a question about the SiLL-Ha ST-4910 and is the answer not in the manual?

Questions and answers

Summary of Contents for Arkray SiLL-Ha ST-4910

  • Page 1 Quick Reference Guide Refer to SiLL-Ha Operating Manual for complete instructions for use, warnings and cautions. For Customer or Technical Service, please call: 844.559.0842. Oral Wellness System Caution: Patients should be advised to NOT drink, eat or brush their teeth two hours prior to the testing for best results.
  • Page 2 The composition of saliva reflects oral health condition. Saliva is known to indicate tooth and gum health but cannot be used to diagnose them. Operating Manual Outside the range: NG. There is a problem with the instrument. Contact the manufacturer. Minneapolis, MN 55439 • 844.559.0842 • www.arkrayusa.com © ARKRAY USA, Inc. All rights reserved. 5535-00 Rev. 05/18...