Technical data
RF input and output
RF loop-through
87.5 – 790 MHz, gain 0–3 dB to each output
Modulator output channel
E21 – E60, set via Sky menu
Modulation
UK System I (DSB), level approx. 70 dBμV at each output
AV and power interface
Sky I/O port via 0.5 m flying lead
Remote control – see note below
IR 'eye' current available (9 V)
10 mA max via each output, s/c protected
(no external PSU)
total current must not exceed 15 mA
System load with external 12 V PSU
75 mA max. via RF - OUT 2 only, s/c protected
Connectors and standards
RF-IN
'IEC' (female) (IEC 61169-2)
RF-OUT
Type-F (female) (IEC 61169-24)
Sky I/O
10-pin mini-DIN (proprietary interface)
Operating temperature rang
0 – +40 °C
External DC power
2.1/5.5 mm DC jack (centre pin +ve)
EMC standards
BS EN 55013 & BS EN 55020
Note: Maximum eye current loading on RF outputs (without external PSU)
Using PROception proSAT1EYE (Mk 2 or later) a maximum of three eyes may be connected, two
via a splitter on one output and one directly connected on the other.
Using other makes of eye (where current loading may exceed 7.5 mA) only one eye is
permitted.
Exceeding these limits will overload the internal DC-DC voltage converter and may damage the
unit.
2-Year Guarantee
This guarantee covers failure of your PROception product resulting from manufacturing defect
within a period of 2 years from the date of supply to the end-user.
This guarantee does not cover damage to the product caused by abuse, tampering, defective
installation or natural causes such as lightning discharge. Repair or attempted repair, other than
by the manufacturer, will render this guarantee void.
This guarantee does not affect a consumer's statutory rights.
Performance data given are typical unless otherwise stated. Proception Limited reserves the right
to change product designs and specifications without notice
'Freeview' is a registered trade mark of DTV Services Ltd.
'Sky', is a registered trade mark of Sky International AG.
Proception Limited
177–187 Rutland Road
SHEFFIELD S3 9PT
United Kingdom
Web:
http://www.proception.co.uk
e-mail: support@proception.co.uk
Page 4
PROception
For use with Sky Satellite Receivers
INSTRUCTIONS FOR INSTALLATION AND USE
The proLINK22 is a versatile UHF analogue modulator intended for use with newer Sky
set-top receivers without RF outputs (e.g. DRX595). This unit connects to the I/O port on
the Sky receiver and replaces the RF distribution and remote control functions previously
available from the RF - OUT 1 and RF - OUT 2 connectors.
Additional features
■ RF loop-through for Freeview, etc., replaces Sky ANT - IN connector.
■ Modulator output coverage: RF channels 21 – 60. Simple RF channel setting using
the Sky box Setup menu.
■ Remote control capability on both RF outputs – supports up to two remote outlets
with IR 'eyes', (where no local RF output is required).
■ A third output location can be supported by using a splitter (see text).
■ External power supply option allows construction of larger systems.
■ 3-colour power status LED.
Location
The modulator can be located in any convenient position close to the Sky receiver box
and does not require fixing. Clearance of at least 25 mm should be allowed around the
front and sides of unit for ventilation. Avoid positioning the modulator on top of a stack
of other equipment as this may result in overheating. The fixing lugs may be used if
desired to secure the unit to a cabinet etc. (screws not supplied).
Power supply and indicator
The modulator is powered from the associated Sky receiver via the I/O link cable. No
separate power supply unit is required unless a larger distribution system (usually 4 or
more output locations) is to be installed.
For larger systems, where a line-powered distribution amplifier such as the proAMP104X
or proMHD14R is used, an external proPSA123 or proPSA125 power unit must be
connected to the modulator. If a locally powered distribution amplifier is used (proAMP-R
series or proAMP310X with local PSU) the modulator will not require a separate power
unit.
The power status LED on the front of the unit works as follows:
LED colour
Sky box power
External PSU
OFF or not
Green
ON
installed
Orange
ON
ON
Red
OFF
ON
proLINK22
UHF Modulator
Status
Normal condition for system with no
external power unit.
Normal condition for system with
external power unit.
Sky box powered down or booting up.
Invalid or fault condition if persistent.
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the proLINK22 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PROception proLINK22

  • Page 1 ■ A third output location can be supported by using a splitter (see text). ■ Using PROception proSAT1EYE (Mk 2 or later) a maximum of three eyes may be connected, two ■ External power supply option allows construction of larger systems.
  • Page 2 Output connections and control ‘eyes’ The proLINK22 has two RF outputs each of which can be connected directly to a TV receiver or connected via an infrared receiver ‘eye’ to provide remote control of the Sky proLINK22 box. These outputs work as follows: ■...