5-1. Overview

What is the outdoor unit maintenance remote controller?

Beginning with the DC-INV series of outdoor units, nonvolatile memory (EEPROM) is
used in the outdoor unit PCB. In this way, the setting switches that were located on
earlier PCBs have been converted to EEPROM data. This remote controller is an
outdoor unit maintenance tool that is used to make and change the EEPROM set-
tings.
This remote controller can be used for checking the outdoor unit EEPROM settings
and contents, and also can be used to monitor the outdoor unit alarm history and
indoor/outdoor unit temperatures, and to check the status of the indoor unit connec-
tions (No. of units, operating status, etc.).
Note: Because this tool does not function as a remote controller, it is used only
during test runs and servicing.

System diagram

Special service checker wiring
(Optional, Servicing No:8540528057900)
1
*
The special service checker wiring is required in order to connect the outdoor unit maintenance remote control-
ler to the outdoor unit PCB.
*
Even when the outdoor unit maintenance remote controller is connected, a separate remote controller or other
control device must be connected to the indoor unit.
2

5-2. Functions

Normal display functions
(1) Functions: Button operations can be used to perform the following functions.
Start/stop of all indoor units
Switching between cooling and heating
3
Test run of all indoor units
High-speed operation of indoor units (Do not use with actual units. This may damage the devices.)
(2) Display: The following can be displayed.
Alarm details display
No. of indoor/outdoor units
Unit Nos. of connected indoor/outdoor units
4
Indoor/outdoor unit operating status (blinks when an alarm occurs)
Indoor unit thermostat ON
Individual display of outdoor unit alarms
Outdoor unit compressor total operating time
Outdoor unit oil sensor oil level
5
Outdoor unit total power ON time
Outdoor unit microcomputer version
Other
Temperature monitor
Displays the indoor/outdoor unit sensor temperatures.
Outdoor unit alarm history monitor
6
Displays the outdoor unit alarm history.
Setting modes
Setting mode 1 and setting mode 2 are used to make the outdoor EEPROM setting.
Outdoor unit maintenance
remote controller
Remote controller
5. Outdoor unit maintenance remote control
Outdoor unit
Inter-unit control wiring (main bus)
Outdoor unit
control PCB
V-2
RCS-TM80BG
Indoor
Indoor
unit
unit
Remote
Remote
controller
controller
SM831148