ATTENTION
Use this manual when installing combined
models of indoor unit KS2432A and outdoor
unit C2432 or CL2432 only.
On items not included in this manual, see the
Installation Instructions (No. 85464179694003)
packed in the outdoor unit model C2432 or
CL2432.
Contents
Please Read Before Starting .................................. 1
1.
GENERAL .......................................................... 2
2.
INSTALLATION SITE SELECTION ................... 3
3.
85264189704003 © SANYO 2003
INSTALLATION INSTRUCTIONS
- Split System Air Conditioner -
Page
SANYO FISHER COMPANY
A DIVISION OF SANYO NORTH AMERICA CORPORATION
21605 Plummer Street
Chatsworth, CA 91311 U.S.A.
Model Combinations
Combine indoor and outdoor units only as listed
below.
Indoor Unit
KS2432A
Power supply: 60Hz, single-phase, 208/230V
Units should be installed by a licensed contractor
according to local code requirements.
4.
REFRIGERANT TUBING.................................. 13
5.
POSITION ......................................................... 16
COOL/DRY Model
Outdoor Units
C2432
CL2432
In Canada
SANYO Canada Inc.
300 Applewood Crescent
Concord, Ontario
L4K 5C7, Canada
W

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo C2432

  • Page 1: Table Of Contents

    KS2432A and outdoor unit C2432 or CL2432 only. On items not included in this manual, see the Installation Instructions (No. 85464179694003) packed in the outdoor unit model C2432 or CL2432. Contents IMPORTANT! Please Read Before Starting ... 1 GENERAL ...
  • Page 2: Important

    Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin alu- minum fins on the air conditioner can cut your fingers. When Installing… …In a Ceiling, Wall or Floor Make sure the ceiling/wall/floor is strong enough to hold the unit’s weight.
  • Page 3: General

    1. General This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning.
  • Page 4: Additional Materials Required For Installation

    Max. Allowable Tubing Model Length at Shipment (ft.) C2432, CL2432 * If total tubing length becomes 25 to 132 ft. (max.), additional refrigerant (R22) charge of 0.27 oz./ft. is required. No additional charge of compressor oil is necessary. 6 inches min.
  • Page 5: Outdoor Unit

    2-2. Outdoor Unit AVOID: heat sources, exhaust fans, etc. (Fig. 4a) damp, humid or uneven locations. choose a place as cool as possible. choose a place that is well ventilated. allow enough room around the unit for air intake/ exhaust and possible maintenance. (Fig. 4b) provide a solid base a minimum of 6 inches above ground level to reduce humidity and protect the unit against possible water damage and decreased service...
  • Page 6: How To Install The Indoor Unit

    3. How to Install the Indoor Unit 3-1. Remove the Rear Panel from the Unit Remove and discard the set screws and take off the rear panel. (Fig. 6) NOTE Tubing can be extended in 3 directions as shown in Fig.
  • Page 7: Install The Rear Panel On The Wall

    3-3. Install the Rear Panel on the Wall Be sure to confirm that the wall is strong enough to sus- pend the unit. See either Item a) or b) below depending on the wall type. a) If Wooden Wall (1) Attach the rear panel to the wall with the 10 screws provided.
  • Page 8: Shape The Indoor Side Tubing

    How to replace the grille (1) Close the flaps. (2) Reinstall the grille into the lower part while aligning its tabs on the upper part. (Fig. 15a) Insert the tabs in the slots and push the lower part of the grille back into position.
  • Page 9: Recommended Wire Length And Diameter

    “A” and “B” in Table 5. Table 5 (A) Power Supply Wiring Length (ft.) Model C2432, CL2432 Be sure to comply with local WARNING codes on running the wire from the indoor unit to the outdoor unit (size of wire and wiring method, etc.).
  • Page 10: Wiring Instructions For Inter-Unit Connections

    3-8. Wiring Instructions for Inter-unit Connections (1) Insert the inter-unit wiring (according to local codes) into the through-the-wall PVC pipe. Run the wiring toward the indoor side allowing approx. 10 inch to extend from the wall face. (Fig. 19) (2) Route the inter-unit wiring from the back of the indoor unit and pull it toward the front for connection.
  • Page 11 Loose wiring may cause the WARNING terminal to overheat or result in unit malfunction. A fire haz- ard may also exist. Therefore, be sure all wiring is tightly connected. When connecting each power wire to the corresponding terminal, follow the instructions “How to connect wiring to the terminal”...
  • Page 12: Mounting

    (3) Carefully bend the tubing (if necessary) to run along the wall in the direction of the outdoor unit and then tape as far as the fittings. The air conditioner’s perfor- CAUTION mance will be deteriorated if a tube is crushed. To prevent crushing of the tube, avoid sharp bends.
  • Page 13: Drain Hose

    3-10. Drain Hose a) The drain hose should be slanted downward to the outdoors. (Fig. 28) b) Never form a trap in the course of the hose. If the drain hose will run in the room, insulate the hose with insulation* so that chilled condensation will not damage furniture or floors.
  • Page 14: Refrigerant Tubing

    4. Refrigerant Tubing 4-1. Indoor Unit Tubing Rear-left tubing NOTE For rear-left tubing, optional tube connection (C) (APR- EN46U1B) is necessary. Please consult your nearest sales outlet or A/C workshop. 1. Make a 3-3/16" hole in the wall, centered on the crossing point between the triangle marks (A and B) on the rear panel.
  • Page 15: Connecting Tubing Between Indoor And Outdoor Units

    Approx. 870 – 1,040 lbs. . in (100 – 120 N . m) 3/4inch 4-4. Insulation of Refrigerant Tubing (For C2432 and CL2432) IMPORTANT To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material.
  • Page 16: Finishing The Installation

    (2) Wrap the armoring tape from the bottom of the out- door unit to the top of the tubing where it enters the wall. As you wrap the tubing, overlap half of each previous tape turn. (Fig. 36) (3) Clamp the tubing bundle to the wall, using 1 clamp approx.
  • Page 17: Remote Control Unit Installation Position

    In direct sunlight Behind a curtain or other place where it is covered More than 26 ft. (8 m) away from the air conditioner In the path of the air conditioner’s airstream Where it may become extremely hot or cold...