Agilent ESA-E Series
Spectrum Analyzer
Confi guration Guide
This ESA configuration guide will help you determine
which performance options, measurement personali-
ties, accessories, and services to include in your new
ESA-E, or to add as upgrades to an existing ESA-E.
Options for the new EXA signal analyzer are shown
alongside the ESA to help cutomers who wish to
migrate to the latest technology. Customers looking
for increased speed, more application options, or
modern connectivity will benefit by moving to the
new EXA signal analyzer.
Tested. Trusted. Reliable.

Advertisement

loading
Need help?

Need help?

Do you have a question about the E4402B and is the answer not in the manual?

Questions and answers

Summary of Contents for Agilent Technologies E4402B

  • Page 1 Agilent ESA-E Series Spectrum Analyzer Confi guration Guide This ESA configuration guide will help you determine which performance options, measurement personali- ties, accessories, and services to include in your new ESA-E, or to add as upgrades to an existing ESA-E. Options for the new EXA signal analyzer are shown alongside the ESA to help cutomers who wish to migrate to the latest technology.
  • Page 2: Table Of Contents

    Agilent ESA-E Spectrum Analyzer This step-by-step guide will help you confi gure your ESA-E. Capabilities that are listed as standard come with the instrument at no additional charge. Tailor the performance, exterior, and service packages to meet your requirements. The ESA-E spectrum analyzer is available in three express confi...
  • Page 3: Esa-E Custom Confi Guration

    EXA signal analyzer Preamplifier Option 1DS N9010A-P03 1 MHz to 3 GHz 100 kHz to 3.6 GHz 1. The E4402B has six available expansion slots for additional hardware options: the E4404/05/07B has five available expansion slots 2. Requires one expansion slot...
  • Page 4 ESA-E Custom Confi guration – continued Step 6. Add extra options Description ESA-E spectrum analyzer EXA signal analyzer Narrow resolution bandwidths Option 1DR Standard (recommended option) Low-emissions shielding Option 060 Not available Wide-offset phase noise improvement and Option 120 Similar performance standard ACPR dynamic range extension Replace GPIB with serial port Option 1AX...
  • Page 5 ESA-E Custom Confi guration – continued Step 7. Choose measurement software Description ESA-E spectrum analyzer EXA signal analyzer AM demodulation Standard N9063A FM demodulation/ deviation Option BAA N9063A Phase noise measurement Option 226 N9068A Noise fi gure measurement Option 219 N9069A GSM/GPRS measurement Option BAH...
  • Page 6: Esa-E Standard Express Spectrum Analyzer (Std/Stg)

    Aging rate: ±1 x 10 –7 / year measurements; recommended option) 1. The E4402B has three expansion slots for additional options; the E4404/5/7B have two expansion slots 2. Requires one expansion slot 3. Not compatible with Options 304 or 106...
  • Page 7 Future upgrades for the ESA-E standard express spectrum analyzer (STD/SG) Available future expansion slots E4402B – Three additional expansion slots E4404/5/7B – Two additional expansion slots 1. If more than two ESA-E options are ordered, memory size may limit the number of options that can be loaded at any one time; for detailed information about memory size limitations, please see the Web site: http://sa.tm.agilent.com/ESA/memory...
  • Page 8: Esa-E Communications Test Express Spectrum Analyzer (Com)

    Time-gated spectrum analysis Options 1D6 Standard 1. The E4402B has two expansion slots for additional hardware options; the E4404/05/07B has one expansion slot 2. Requires one expansion slot 3. Requires Options B7D/B7E, A4H, and 1D5 4. Not compatible with Option 304 or 106 5.
  • Page 9: Express Analyzer And Bundle Equivalent Options

    Future upgrades for the ESA-E standard express spectrum analyzer (STD/SG) Available future expansion slots E4402B – Three additional expansion slots E4404/5/7B – Two additional expansion slots 1. If more than two or three ESA-E options are ordered, memory size may limit the number of options that can be loaded at any one time;...
  • Page 10: Esa-E Accessory, Calibration, And Warranty Options

    ESA-E Accessory, Calibration, and Warranty Options Step 6. Select accessories and calibration options Description ESA-E spectrum ESA-E notes ESA-E part number EXA signal analyzer option analyzer option 12 VDC power cable DC power connection E4401-60066 Not available available on every ESA Hard transit case E4401-60101 N9010A-HTC...
  • Page 11: Esa-E Upgrade Options

    MY4144; required for fi rmware version A.08.00 or higher High stability frequency reference E4401B X X E4402B/04B/05B/07B (SN prefi x before 4421) SN prefi xes US4421, MY4421, SG4421 or later IF sweep, video output ports Not compatible with AYX; occupies one expansion slot Applications and fi...
  • Page 12: Related Literature

    Get the best of both worlds: Agilent’s Get the latest information on the © Agilent Technologies, Inc. 2010 measurement expertise and product products and applications you select. Printed in USA, June 2, 2010 breadth, combined with channel 5989-9953EN partner convenience.