Summary of Contents for National Instruments FP-AI-102

  • Page 1 National Instruments FP-AI-102 Manual Get Pricing & Availability at ApexWaves.com Call Today: 1-800-915-6216 Email: sales@apexwaves.com https://www.apexwaves.com/modular-systems/national-instruments/fieldpoint/FP-AI-102...
  • Page 2 FieldPoint™, National Instruments™, NI™, and ni.com™ are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents .
  • Page 3 1. Slide the terminal base key to either position X (used for any module) or position 1 (used for the FP-AI-102 module). 2. Align the FP-AI-102 alignment slots with the guide rails on the terminal base. 3. Press firmly to seat the FP-AI-102 on the terminal base. When the module is firmly seated, the terminal base latch locks it into place.
  • Page 4 Figure 2. Installing the cFP-AI-102 Wiring the [c]FP-AI-102 The FP-TB-x terminal bases have connections for each of the eight input channels on the FP-AI-102 and for an external supply to power field devices. The cFP-CB-x connector blocks provide the same connections for the cFP-AI-102.
  • Page 5 COM terminals. Refer to the following section for detailed wiring diagrams. Cascading power between two modules defeats Caution isolation between those modules. Cascading power from the network module defeats all isolation between modules in the FieldPoint system. FP-AI-102 and cFP-AI-102 ni.com...
  • Page 6 Measuring Voltage with the [c]FP-AI-102 The [c]FP-AI-102 has eight single-ended input channels. All eight channels share a common ground reference that is isolated from other modules in the FieldPoint system. Figure 3 shows the analog input circuitry on one channel.
  • Page 7: Status Indicators

    Status Indicators The [c]FP-AI-102 has two green status LEDs, POWER and READY. After you insert the [c]FP-AI-102 into a terminal base or backplane and apply power to the connected network module, the green POWER indicator lights and the [c]FP-AI-102 informs the network module of its presence.
  • Page 8: Isolation And Safety Guidelines

    [c]FP-AI-102 to any circuits that may contain hazardous voltages. This section describes the isolation of the [c]FP-AI-102 and its compliance with international safety standards. The field wiring connections are isolated from the backplane and the inter-module communication bus.
  • Page 9: Specifications

    [c]FP-AI-102 as the only isolating barrier between human contact and working voltages of more than 250 V • Operate the [c]FP-AI-102 only at or below Pollution Degree 2. Pollution Degree 2 means that only nonconductive pollution occurs in most cases. Occasionally, however, a temporary conductivity caused by condensation must be expected.
  • Page 10 Signal input bandwidth ..... 170 Hz Physical Indicators .......... Green POWER and READY indicators Weight FP-AI-102........145 g (5.1 oz) cFP-AI-102......... 115 g (4.0 oz) Power Requirements Power from network module .... 400 mW Isolation Voltage Maximum isolation voltage ....250 V...
  • Page 11 10–500 Hz, 5 g Operating vibration, sinusoidal (IEC 60068-2-6) [c]FP-AI-102 ......10–500 Hz, 5 g Safety The [c]FP-AI-102 is designed to meet the requirements of the following standards for safety and electrical equipment for measurement, control, and laboratory use. •...
  • Page 12 Declaration of Conformity at ni.com/hardref.nsf/ Mechanical Dimensions Figure 6 shows the mechanical dimensions of the FP-AI-102 installed on a terminal base. Dimensions are given in millimeters [inches]. If you are using the cFP-AI-102, refer to the cFP controller user manual for the dimensions and cabling clearance requirements of the Compact FieldPoint system.
  • Page 13: Where To Go For Support

    Where to Go for Support For more information about setting up the FieldPoint system, refer to these National Instruments documents: • FieldPoint network module user manual • Other FieldPoint I/O module operating instructions • FieldPoint terminal base operating instructions Go to for the most current manuals, examples, ni.com/support...