REPAIRS AND / OR SERVICE TO THIS TOOL MUST ONLY BE DONE BY AN AUTHORIZED AND CERTIFIED DEALER. For the nearest certified dealer, call STANLEY Infrastructure at (503) 659-5660 and ask for a Customer Service Representative. TA54 User Manual ◄ 3...
Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULATIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and maintenance personnel. 4 ► TA54 User Manual...
The TA54 Hydraulic Tamper will provide safe and • Do not exceed the rated limits of the tool or use the dependable service if operated in accordance with the tool for applications beyond its design capacity.
OPERATION MANUAL. OPERATION MANUAL. TAG TO BE REMOVED ONLY BY TAG TO BE REMOVED ONLY BY TOOL OPERATOR. TOOL OPERATOR. SEE OTHER SIDE SEE OTHER SIDE SAFETY TAG P/N 15875 (Shown smaller then actual size) 6 ► TA54 User Manual...
This hose is not certifi ed non-conductive and must never be used near electrical conductors. HOSE SAFETY TAGS To help ensure your safety, the following DANGER tags are attached to all hose purchased from STANLEY. DO NOT REMOVE THESE TAGS.
2000 psi 2000 psi (At the power supply outlet) (172 bar) (138 bar) (138 bar) (138 bar) (138 bar) Note: These are general hydraulic system requirements. See tool specifi cation page for tool specifi c requirements. TA54 User Manual ◄ 9...
Note: Partially depressing the trigger allows the tool to operate at a slow speed, making it easy to start the tamper on the surface to compacted. 4. Guide the tamper using both hands. One on the On/ 10 ► TA54 User Manual...
Do not reverse circuit flow. This can cause damage to internal seals. • Always replace hoses, couplings and other parts with replacement parts recommended by STANLEY. Supply hoses must have a minimum working pressure rating of 2500 psi/172 bar. •...
Provide cooler to maintain proper oil temperature. Bypass cooler to warm up oil or provide cooler to maintain proper temperature (100–130 °F/38–54 °C). Eliminate flow control devices. Do not exceed recommended flow. 12 ► TA54 User Manual...
Page 13
2. Oil tubes reversed at ON/OFF valve. 3. Front sleeve in correctly. 4. Thrust bridge washer in correctly. Back-pressure too high. Check hydraulic system for excessive back-pressure over 250 psi/17 bar measure at the end of the tool operating hoses. TA54 User Manual ◄ 13...
THESE 3 PARTS NEW INLINE VALVE Torque to 40 ft lb Lubricat- ed. Light coat of grease on piston taper & capscrew threads. NOTE: Round shoe found on the following models: TA54113, TA54113D & TA54113S P/N-00840 TA54 User Manual ◄ 15...
Note: Individual parts are still available for the older (NEW IN-LINE VALVE)) in-line valve, but if replacing the entire in-line valve 13568 BACK-UP RING (TA54603A ONLY) assy, you must order the new in-line valve assy P/N- (OLD IN-LINE VALVE) 72264. 16 ► TA54 User Manual...
Page 20