Download Print this page
Anderson LN Quick Start Installation Manual

Anderson LN Quick Start Installation Manual

Ln potentiometric level transmitter

Advertisement

Quick Links

Anderson Instrument Co., Inc.
156 Auriesville Road
Fultonville, NY 12072
Phone: 518-922-5315 or 800-833-0081
www.anderson-negele.com
1. Insert cable through Pressing Screw, Compression
Ring, Seal Grommet, and Sleeve as shown below.
2. Strip back 1-1/4" of outer sheathing, cut off any excess
wires, shield and ground. Strip off 1/4" insulation from
remaining four wires. It is not necessary or recommended
Shown With
Cap Removed
CABLE REQUIREMENTS
 4 conductor, stranded, 18-24 AWG,
shielded with ground.
 4-8mm (0.16-0.31") Cable Sheath
OD.
To install connector, simply line up key, press
into receptacle, and hand-tighten the
*Receptacle pins should be coated with
USDA approved dielectric grease to
Minimize possibility of corrosion.
Rev. 2.1
Section 1 - Field Wireable Connector
3. Orient Connector end so that
center pin connecting screw is
horizontal facing right (see
detail).
Retaining Ring
Connector End
Pin 2 - Black
(-PWR)
Pin 3 - Green
(LOOP- Return)
DETAIL
*Dielectric Grease
P/N: 5662400000
Doc 1136
Technical Bulletin
LN Potentiometric Level Transmitter
Quick Start Installation Guide
4. Wire PWR + (red) wire to top-right
terminal, and PWR - (black) wire to
top-left terminal. Wire LOOP + (white) to
center terminal and LOOP - (green) to
bottom left terminal.
5. Screw on the Sleeve. Hand-tighten only.
Sleeve
Compression
Ring
Seal
-2 included choose one to accommodate cable OD
Grommet
6. Press the Seal Grommet into the Sleeve and
Pin 1 - Red
hand-tighten the Pressing Screw against the
(+PWR 18-36 VDC)
compression ring.
Pin 5 - White
7. Use a wrench to tighten the Pressing Screw
(LOOP+)
another 3/4 turn. Do not over-tighten!
Field Wireable Connector
P/N: 42119B0000 (without cable)
Molded Cord Set - Heavy Duty
P/N: 42117F0025
42117F0050
42117F0100
Molded Cord Set
P/N: 42117K0025
42117K0050
42117K0100
Pressing Screw
Loop+ (white) wire
Loop- return (green) wire
+PWR (red) wire
-PWR (black) wire
Shield (clear or bare) wire
PWR+ (brown) wire
PWR- (white) wire
Loop + (grey) wire
Loop - (blue) wire
Shield (clear or bare) wire
Loop+ (white) wire
Loop- return (green) wire
+PWR (red) wire
-PWR (black) wire
Shield (clear or bare) wire
Note: Green and White not used
on 2 wire devices.
Shield not connected to nut.
Page 1 of 2

Advertisement

loading
Need help?

Need help?

Do you have a question about the LN and is the answer not in the manual?

Questions and answers

Summary of Contents for Anderson LN

  • Page 1 Anderson Instrument Co., Inc. Technical Bulletin 156 Auriesville Road Fultonville, NY 12072 LN Potentiometric Level Transmitter Phone: 518-922-5315 or 800-833-0081 Quick Start Installation Guide www.anderson-negele.com Section 1 - Field Wireable Connector 4. Wire PWR + (red) wire to top-right 1. Insert cable through Pressing Screw, Compression 3.
  • Page 2 Media must have a conductivity of at least 1 µS/cm. Sensitivity • The LN is shipped calibrated to the bottom of the Teflon® coating. Normally at installation, additional Typically adjustment is not required. If calibration is needed, perform adjustments are not required.