IRIS IRMA MATRIX 2 Installation Manual

Infrared motion analyzer 5th generation; can
Table of Contents

Advertisement

Automatic Passenger Counting
IRMA – Infrared Motion Analyzer
th
5
generation
IRMA MATRIX
Release 2
CAN Installation manual
Sensor variants:
DIST500-A
DIST500-F
iris-GmbH | Ostendstrasse 1 – 14 | 12459 Berlin | Germany
www.irisgmbh.de
Rev. 1.6 | 2018-09
Subject to alterations

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IRMA MATRIX 2 and is the answer not in the manual?

Questions and answers

Summary of Contents for IRIS IRMA MATRIX 2

  • Page 1 Automatic Passenger Counting IRMA – Infrared Motion Analyzer generation IRMA MATRIX Release 2 CAN Installation manual Sensor variants: DIST500-A • DIST500-F • iris-GmbH | Ostendstrasse 1 – 14 | 12459 Berlin | Germany Rev. 1.6 | 2018-09 www.irisgmbh.de Subject to alterations...
  • Page 2 2/74 IRMA MATRIX R2 CAN Installation manual released Document information Title of document: IRMA MATRIX R2 CAN Installation manual File name: KDIA_IRMA-MATRIX_R2_Installation-manual-CAN_1.6_en.pdf Revision: Edition (YYYY-MM): 2018-09 Type of document: Customer documentation (KD) Status: released Validity Sensors and connectors covered by this document: Product Item type Item...
  • Page 3: Table Of Contents

    3/74 IRMA MATRIX R2 CAN Installation manual released Table of contents General ......................... 7 On this document ......................... 7 Symbols/abbreviations/designations used ................8 The connector systems ........................ 9 1.3.1 M12 connector of the CAN type....................9 1.3.2 M12 connector of the ETH type ....................9 Important information when working with IRMA MATRIX sensors ......
  • Page 4 4/74 IRMA MATRIX R2 CAN Installation manual released CAN cabling ..........................32 Power supply ......................34 Power supply of IRMA MATRIX sensor .................. 35 IRMA gateway power supply ....................36 The IRMA gateway as an interface adapter .............. 37 Door signal input and on-board computer connection ............ 37 7.1.1 IRMA-Gateway-4-IBIS and IRMA-Gateway-4-RS485.2 ............
  • Page 5 5/74 IRMA MATRIX R2 CAN Installation manual released 12.3.2 Installations with sCON-F-12 ....................68 12.3.3 Installation with second power supply in articulated bus (with sCON-S) ....68 Annex B Drilling patterns ..................74 Table of illustrations Fig. 1: Comparison - DHCP deactivated in old counting firmware ......11 Fig.
  • Page 6 6/74 IRMA MATRIX R2 CAN Installation manual released Fig. 30: "Installation" / representation "Function Area Address" on the vehicle ..49 Fig. 31: Installation parameters section - Parameters in the door area at a glance 50 Fig. 32: Sector “Function area/door” - FA on product label (framed in yellow) ..50 Fig.
  • Page 7: General

    7/74 IRMA MATRIX R2 CAN Installation manual released General On this document This document describes the installation of the IRMA passenger counting system IRMA MATRIX (sensors and IRMA gateway) with CAN cabling as well as the connection to the on-board computer.
  • Page 8: Symbols/Abbreviations/Designations Used

    "Caution - can result in defects" "Information" "See Annex" "See document on our website" "Instructions" "Please note down" "Please contact iris-GmbH" "Download" Setting parameters during configuration are identified as shown on the left. "Door Polarity" iris product designation M12CAN-CON-03 Female connector...
  • Page 9: The Connector Systems

    9/74 IRMA MATRIX R2 CAN Installation manual released The connector systems 1.3.1 M12 connector of the CAN type IRMA CAN sensors are connected to the CAN BUS with 5-pole M12 connectors (m/f). Table 1: Assignment of the CAN type M12 connector (m/f) M12 connector (m) of the CAN type Pin assignment: M12 connector (f), CAN type...
  • Page 10: Important Information When Working With Irma Matrix Sensors

    Important information when working with IRMA MATRIX sensors IRMA MATRIX sensors must only be installed by qualified expert staff trained by iris-GmbH who observe the pertinent regulations and the installation manual. In all considerations with regard to installation positions and orientation, it is assumed that the observer is inside the vehicle.
  • Page 11: Preparation Of The Installation

    11/74 IRMA MATRIX R2 CAN Installation manual released these new parameters are visible, but greyed out and disabled. The following Fig.s show the differences between the old and the new firmware: Under “Ethernet” the DHCP function is visible, but cannot be selected. DHCP is active only in the new firmware version.
  • Page 12: Vehicle Data Sheet

    Vehicle data sheet iris-GmbH offers a vehicle data sheet for vehicles which are to be equipped with the IRMA passenger counting system. This data sheet serves to collect the main installation conditions. Based on the information from the vehicle data sheet we can properly plan your project in advance, thus helping you select the optimal components for your vehicle.
  • Page 13 • Which are the height and width of the doors? In the event of unfavorable door dimensions (very wide and low doors), the installation of 2 sensors can provide optimum coverage of the field of monitoring. This decision must be made in consultation with iris- GmbH.
  • Page 14: Important Information On Sensor Placement

    • Install the sensors in the centre of and as closely as possible to the door. • The maximum distance between the sensor and the vehicle inside wall must not exceed 20 cm. Mounting sensors at a larger distance from the door must be agreed with iris- GmbH before the installation.
  • Page 15: Installation In Center Position Above The Door

    15/74 IRMA MATRIX R2 CAN Installation manual released • “Exterior" must face outwards when mounted. • “Interior" must face inwards when mounted. • In the sensor's close-up range of up to 3 cm from the sensor surface there must not be any horizontal objects which might affect the counting result.
  • Page 16 If it is not possible to install the sensors in the centre of the doors or of the doors are very wide / low, the installation position and the number of sensors for each door must be discussed and agreed in advance with iris-GmbH. Rev. 1.6...
  • Page 17: Mounting

    17/74 IRMA MATRIX R2 CAN Installation manual released Mounting Mounting of the sensor 4.1.1 Selection of the connector version The sCON (connector for sensors) was developed particularly for IRMA MATRIX sensors for the connection to the power supply and data transmission units. Depending on the sensor variant, different sCON variants are available, differing in their geometry and function: •...
  • Page 18: Mounting Of Irma Matrix Sensors Of The Surface Mount Version (Dist500-A)

    18/74 IRMA MATRIX R2 CAN Installation manual released 4.1.2 Mounting of IRMA MATRIX sensors of the surface mount version (DIST500-A) The sensors of the flush mount version (DIST500-A) are placed directly on the door trim and connected to the sCON-S (standard) from the rear. Sensors of the surface mount version cannot be mounted together with the connector version sCON-F-12.
  • Page 19: Mounting Of The Scon-S (Standard)

    19/74 IRMA MATRIX R2 CAN Installation manual released Mounting of the sCON-S (standard) 4.1.2.1 max. 1 Nm sCON base body 1 Knurled scew - locks the connection in place 2 M4 threaded hole for mounting of ground connection 3 Mounting cylinder for cove depths of up to 8 mm 4 Contact surfaces 5 Guiding pins...
  • Page 20: Mounting With Scon-S (Standard)

    20/74 IRMA MATRIX R2 CAN Installation manual released The tools, wrench sizes and mounting sets required for mounting and installation are given in section 12.1.1, p. 63. The mounting set required for attaching an IRMA MATRIX sensor is not part of the delivery and must, therefore, be ordered separately. Mounting with sCON-S (standard) 4.1.3.1 Section 12.1.2, in the Annex on p.
  • Page 21: Fig. 10: Setting, Adjusting And Tightening Of The Cylinder Head Screws

    21/74 IRMA MATRIX R2 CAN Installation manual released 1. Cut the rectangular cutout in the cove, see (4) in Fig. 9, p. 20. The drilling pattern is enclosed in the Annex to this document. Fig. 10: Setting, adjusting and tightening of the cylinder head screws 2.
  • Page 22: Mounting With Scon-F-12

    22/74 IRMA MATRIX R2 CAN Installation manual released is available for ordering in the accessories and can then again be used for wall thicknesses up to 8 mm. 6. For the mounting of the sCON-S (standard) see section 4.1.2.1, p. 19. If the sensor is installed in color-coated metal coves, it must be ensured that the connection between sensor housing and cove is conductive.
  • Page 23: Fig. 13: Mounting With Scon-F-12 - Overview

    23/74 IRMA MATRIX R2 CAN Installation manual released Fig. 13: Mounting with sCON-F-12 – overview 1 Allen countersunk head screw, Allen key size 3 3 Leaf spring for clamping 2 sCON-F-12 4 Cove (here e.g. 4 mm thick) with rectangular cutout 5 IRMA MATRIX sensor DIST500-F (flush mount variant) 1.
  • Page 24: Fig. 14: Scon-F-12 - Positioning And Adjustment

    24/74 IRMA MATRIX R2 CAN Installation manual released Fig. 14: sCON-F-12 - positioning and adjustment 1 sCON-F-12 5 Cove 2 Marking: position of the guiding pins on the bottom side 6 MATRIX sensor DIST500-F (flush mount version) 3 Label indicating the orientation Exterior/Interior (sCON-F-12) 7 Guiding holes on the sCON connection (rear of the sensor) 8 Label indicating the orientation Exterior/Interior (sensor) 4 Countersunk head screws (hexagon socket, size 3)
  • Page 25: Installation Of The Irma Gateway

    2 IRMA MATRIX sensor must be used if the intersection point of door height and door width lies between the blue and red lines. The values indicated are recommendations - in case of deviations please contact iris- GmbH. Rev. 1.6...
  • Page 26: Irma Matrix Sensor Per Door

    26/74 IRMA MATRIX R2 CAN Installation manual released Detection range height vs. width 2 sensors 1 sensor door width [m] Fig. 15: Selection of the number of IRMA MATRIX sensors 4.3.1 1 IRMA MATRIX sensor per door The sensor is fitted in central position above the vehicle door. Fig.
  • Page 27: Irma Matrix Sensors Per Door

    27/74 IRMA MATRIX R2 CAN Installation manual released Deviations from the centre installation position are permissible in accordance with the following formula: ���������������� ���� �������� ���������������� �������� ���� ����ℎ − ������������������������ ���������������� �������� ���� ����ℎ �������������������� ���� �������� ���� ���� ���� ���������������� ���� �������� ���� ���� = The maximum door width with one sensor is taken from Fig.
  • Page 28: Laying And Connection Of The Cables

    Installations in accordance with EN 50343 (railway vehicles) For installations in accordance with EN 50343 (for railway vehicles) cables of the iris cable characteristic "K3" must be used (see section 5.1). This cable is additionally shielded, which yields sufficient electrical isolation.
  • Page 29: Emc-Compatible Installation/Grounding In Accordance With En 50153

    The cables must be laid with sufficient reserve length so that they can be re-fitted to connectors at least three times. When laying the cables the minimum bending radii given in the "Components for IRIS sensors on the CAN BUS" must be observed.
  • Page 30: Connection Of The Grounding Cable To The Scon-S (Standard)

    30/74 IRMA MATRIX R2 CAN Installation manual released 5.3.1 Connection of the grounding cable to the sCON-S (standard) The sCON-S housing is equipped with two M4 threaded holes arranged diagonally for attaching the grounding cable. The cable is attached to the sCON housing using a crimped eyelet, a screw (M4x5) and a serrated washer in the position shown in Fig.
  • Page 31: Connection Of The Grounding Cable To The Irma Gateway Housing

    31/74 IRMA MATRIX R2 CAN Installation manual released 5.3.2 Connection of the grounding cable to the sCON-F-12 Fig. 20 shows the positions on the sCON-F-12 housing provided for connecting the grounding cable. It attached to a threaded hole in the housing using a crimped eyelet, a screw (M4x5) and a serrated washer.
  • Page 32: Can Cabling

    32/74 IRMA MATRIX R2 CAN Installation manual released CAN cabling All available CAN components are shown in the Annex in section 12.2 p. 65 et sequ. Connection examples can be found in section 12.3 from p. 68 on. • An IRMA CAN BUS is a line-type BUS with short branch lines to the BUS devices. •...
  • Page 33 33/74 IRMA MATRIX R2 CAN Installation manual released If cables in direct proximity to H couplers are tied up, ensure that the connections are not bent. There is the risk of the connectors becoming wedged which will result in interruption of the contact and destruction of the plug-in connection in operation.
  • Page 34: Power Supply

    34/74 IRMA MATRIX R2 CAN Installation manual released Power supply The nominal voltage of the sensors is 24 V. If a gateway is installed, it must also supplied with 24 V DC. The supply of 12 V DC is not permissible; a step-up transformer is required. Direct connection to permanent plus is not permitted by VDV 457.
  • Page 35: Power Supply Of Irma Matrix Sensor

    35/74 IRMA MATRIX R2 CAN Installation manual released Power supply of IRMA MATRIX sensor The nominal voltage of the sensor is 24 V. The wires of the cables‘ opened end must be connected as shown in the table below: Table 4: Potential 0 V = VP- 24 V DC = VP+...
  • Page 36: Irma Gateway Power Supply

    36/74 IRMA MATRIX R2 CAN Installation manual released IRMA gateway power supply Cable K-A21-P-XX-xm is connected to the vehicle on-board network. The supply of 12 V DC is not permissible; a step-up transformer is required in addition. Table 5: Pin assignment of "P" connector Assignment Wire color Pin 1...
  • Page 37: The Irma Gateway As An Interface Adapter

    37/74 IRMA MATRIX R2 CAN Installation manual released The IRMA gateway as an interface adapter The IRMA gateway serves as an adapter between the CAN interface and other interfaces. Depending on the IRMA gateway version, the following interfaces are possible: •...
  • Page 38: Irma-Gateway-4-Ibis And Irma-Gateway-4-Rs485.2

    38/74 IRMA MATRIX R2 CAN Installation manual released 7.1.1 IRMA-Gateway-4-IBIS and IRMA-Gateway-4-RS485.2 The connections listed below apply to units IRMA-Gateway-4-IBIS and IRMA-Gateway-4- RS485.2 Table 7: Door contact with evaluation of potential free switches Wire color Jumper to pin 8 Black Jumper to pin 7 Black Switching input_1, contact "b"...
  • Page 39 39/74 IRMA MATRIX R2 CAN Installation manual released Table 8: Door contacts with evaluation of voltage levels Wire color Switching input_1, contact "b" Blue Switching input_1, contact "a" Grey Switching input_2, contact "b" Violet Switching input_2, contact "a" Orange Switching input_3, contact "b" Brown Switching input_3, contact "a"...
  • Page 40: Irma-Gateway-4-Ibis

    40/74 IRMA MATRIX R2 CAN Installation manual released 7.1.2 IRMA-Gateway-4-IBIS In the following the document describes the assignment of the IBIS on-board computer interface for the unit IRMA-Gateway-4-IBIS. Table 9: Pin assignment of IBIS operating interface Wire color Vehicle bus transmission data (+) White Vehicle bus minus transmission (-) Brown...
  • Page 41: Irma-Gateway-J1708

    41/74 IRMA MATRIX R2 CAN Installation manual released 7.1.4 IRMA-Gateway-J1708 The IRMA gateway with J1708 interface differs from the units described above in a number of relevant points. Therefore its pin assignment is given separately. Table 11: Pin assignment of operating interface J1708 when using potential free door contact switches Wire color Ground...
  • Page 42 42/74 IRMA MATRIX R2 CAN Installation manual released Table 12: Pin assignment of operating interface J1708 when using potential free door contact switches Wire color Ground Data, pos. pole Yellow Data, neg. pole Green Reference potential J1708 Reference potential J1708 Door 3, contact "b"...
  • Page 43: Sensor Configuration

    43/74 IRMA MATRIX R2 CAN Installation manual released Sensor configuration Connection to the service PC For the configuration a laptop with Windows XP, Vista, 7 or 8 is required. The service laptop is connected either • via a CAN USB converter (accessories) to an USB interface on the PC (see section 8.1.1) •...
  • Page 44: Pc Connection Via Ethernet Interface

    44/74 IRMA MATRIX R2 CAN Installation manual released Fig. 24: Opening of the BUS with H coupler for connection of the CAN-USB converter 1 SUB-D9-M12 adapter without terminator, 3 M12 extension cable of the CAN type, K-M12CAN-03-x K-A21-M12CAN-oP-01-32cm 4 M12 termination connactor (m) of the CAN type, M12CAN-TR-02 2 M12-H coupler of the CAN type, M12CAN-CON-03 5 CAN-USB converter A firmware update via CAN-USB converter takes up to 25 minutes for each sensor.
  • Page 45: Pc Connection With Scon-S (Standard) Of The Type Scon-S-Can-Eth-23-K2-X-Y

    45/74 IRMA MATRIX R2 CAN Installation manual released PC connection with sCON-S (standard) of the type 8.1.2.1 sCON-S-CAN-ETH-23-K2-x-y The sCON-S of the sCON-S-CAN-ETH-23-K2-x-y type with its interfaces for CAN and Ethernet and the cables required for connection can be seen from section 12.2, p. 65, as CAN component.
  • Page 46: Fig. 26: Service Connection To An Installation With Scon-F-12

    46/74 IRMA MATRIX R2 CAN Installation manual released Fig. 26: Service connection to an installation with sCON-F-12 1 Flat sCON-F-12 with MATRIX sensor DIST500-F (flush mount version) 4 Commercial patch cable with 2x Rj45 connector (m) 2 M12 connector (f), ETH type (connection ) is the Ethernet 5 M12 protective cap connection to the sCON-F-12 3 M12-RJ45 adapter, KQ-M12CAT5-RJ45-01-xm...
  • Page 47: Configuration Using Dist500-Configuration

    47/74 IRMA MATRIX R2 CAN Installation manual released Configuration using DIST500-Configuration The service software "DIST500-Configuration 3.9.6.187" and higher is used for the configuration of the system. The Configuration Tool instructions describe the individual steps of the configuration in detail. 8.2.1 Update to the current service software required! Fig.
  • Page 48: Sensor Selection

    48/74 IRMA MATRIX R2 CAN Installation manual released 8.2.3 Sensor selection In the sensor selection dialogue the option “UIP-over-UDP” (see Fig. 28) must be active as otherwise no sensors are shown at all. As a rule, “UIP-over-UDP” is pre-set. 8.2.4 Option DHCP Fig.
  • Page 49: Configuration Parameters (New Counting Firmware)

    49/74 IRMA MATRIX R2 CAN Installation manual released 8.2.5 Configuration parameters (new counting firmware) Fig. 30: "Installation" / representation "Function Area Address" on the vehicle This arrow indicates parameters which must be adjusted to their environment on each installation. Rev. 1.6 2018-09...
  • Page 50: Fig. 31: Installation Parameters Section - Parameters In The Door Area At A Glance

    “Function Area Address” (FA) – Corresponds to the logically assigned door number(s) where the sensors/sensor groups are installed. The manner of assigning door/function area addresses established by iris-GmbH is shown in Fig. 32. Upon delivery, the FA setting is indicated on the product label, see Fig. 32. Here e.g. the indication “FA:1#1”...
  • Page 51: Fig. 33: Sector "Mounting Height

    51/74 IRMA MATRIX R2 CAN Installation manual released The Extended data sheet for IRMA MATRIX contains a detailed description of the nameplate. “Door Address/Door Contact Input (1…4, for Gateway only)” – The door contact input starts or stops the counting operation of the IRMA MATRIX sensor. In case of an existing CAN gateway installation the door contact input corresponds to the door signal inputs of the gateway.
  • Page 52: Fig. 34: Sector "Wall Distance (Left, Right)

    This parameter marks the boundary between the inside and the outside of the vehicle in order to differentiate between boarding the vehicle and alighting from it. If the installation distance exceeds 20 cm, absolutely contact iris-GmbH. Measure the distance and enter the value measured.
  • Page 53: Fig. 36: Sector "Vehicle Edge Offset

    53/74 IRMA MATRIX R2 CAN Installation manual released marker. Measure the difference in height between the vehicle edge and the adhesive marking and • set the measured value as positive (> 0 mm) if the vehicle edge is below the adhesive marker.
  • Page 54: Fig. 38: Sector "Door Clearance (Left, Right)

    54/74 IRMA MATRIX R2 CAN Installation manual released “Left door clearance” – (passage width) is the horizontal distance between the sensor and the left opened door parallel to the vehicle edge. Enter 0 mm if there is no opened door in the sensor viewing range. “Right door clearance”...
  • Page 55: Irma Gateway Configuration

    55/74 IRMA MATRIX R2 CAN Installation manual released Opening angle (left, right) - outward swinging doors like here are mainly to be found in the USA and in Central and South America IRMA gateway configuration Connection of the IRMA gateway to the PC Your PC must have free USB or RS232 interface •...
  • Page 56: Fig. 40: On The Left: Start The "A21_Assistent" Software / On The Right: Splash Screen Of "A21_Assistent

    56/74 IRMA MATRIX R2 CAN Installation manual released Fig. 40: On the left: start the "A21_Assistent" software / on the right: splash screen of "A21_Assistent" In the splash screen of the "A21_Assistent" the connection conditions are checked on the Update the COM interface (≠COM1) and select the protocol of the IRMA gateway firmware (J1708/IBIS).
  • Page 57: Fig. 41: Configuration Menu For Irma Gateway

    57/74 IRMA MATRIX R2 CAN Installation manual released Fig. 41: Configuration menu for IRMA gateway • The active firmware of the IRMA gateway is shown (red marking). • The following parameters can be set: • "Baud Rate": suitable for the protocol (for IBIS=1200 bps/for J1708=9600 bps) •...
  • Page 58: Check Of The Installation

    • No counting zone must report defective or sabotaged sensors or sensors "busy counting". • All doors must be reported "closed". UIP- Universal IRMA protocol: proprietary protocol of iris-GmbH for communication between the individual passenger counting components Rev. 1.6 2018-09...
  • Page 59 Query the counting result (in case of incorrect counting results this procedure is to be repeated no more than twice). • Repeat this operation for all doors. UIP- Universal IRMA protocol: proprietary protocol of iris-GmbH for communication between the individual passenger counting components Rev. 1.6...
  • Page 60: Fig. 42: Flowchart (Protocol Variants: Ibis, Irma (Uip), J1708)

    60/74 IRMA MATRIX R2 CAN Installation manual released Connect laptop to gateway Close all vehicle doors Start "IRMA-A21-Windows“ Select “Communication” J1708 IBIS Select protocol: IBIS, IRMA (UIP) or IRMA ? IRMA (UIP) All counting All counting All counting areas areas areas present? present?
  • Page 61: Fig. 43: Flowchart For Checking The Counting Operation

    61/74 IRMA MATRIX R2 CAN Installation manual released Door status <bW>: "b1" = closed, "b0" = open Close all vehicle doors Start “IRMA-A21-Windows” Select “Communication” ->IBIS IRMA (UIP) or J1708R? Test on next door Open vehicle door Mount 5 times Close vehicle door Counting result...
  • Page 62: Test Ride/Signal Recording

    • Any disturbances caused by external infrared signals must be eliminated by taking adequate measures in cooperation with iris-GmbH. • If problems occur during installation, please inform iris-GmbH. • The sensor must be installed in its optimum position: • The maximum installation height of the sensors of presently 2.40 m must not be exceeded.
  • Page 63: Annex A

    < ± 5°. • On doors with special dimensions (installation height < 1.90 m and very, very wide door areas) the installation must be performed in consultation with iris-GmbH. If necessary, 2 sensors are installed above the door.
  • Page 64: Installation Conditions For Irma Matrix Sensors With Different Sensor/Connector Versions

    64/74 IRMA MATRIX R2 CAN Installation manual released 12.1.2 Installation conditions for IRMA MATRIX sensors with different sensor/connector versions Table 13: Installation conditions for IRMA MATRIX sensors with different sensor/connector versions (required mounting depth, mounting sets and tools) IRMA MATRIX sensor version Required mounting depth sCON type designation Mounting sets...
  • Page 65: Components For Irma Matrix Sensors On Can Bus

    65/74 IRMA MATRIX R2 CAN Installation manual released 12.2 Components for IRMA MATRIX Sensors on CAN BUS Table 14: Overview of the IRMA components on CAN BUS Connector (f) type Symbol Symbol Connector (m) type M12 connector (f), CAN type M12 connector (m), CAN type M12 connector (f), ETH type M12 connector (m), ETH type...
  • Page 66 66/74 IRMA MATRIX R2 CAN Installation manual released No. Designation Description/function Drawing/product designation MATRIX sensor Connection possible only with sCON-S DIST500-A (standard), see item Nos. 9 and 10! (surface mount version) DIST500.7-A07.OC MATRIX sensor Connection with connector: DIST500-F - sCON-S (standard), see item Nos. 9 (flush mount and 10 DIST500.7-F07.OC...
  • Page 67 67/74 IRMA MATRIX R2 CAN Installation manual released No. Designation Description Drawing/product designation Power supply 2 wires and shield for connection of cable the power supply to the CAN BUS K-M12POW-B-04-2m (=K3) M12 connector (f), CAN type/2 wires K-M12POW-B-oE-04-2m (=K3) and shield of opened cable end Connecting 4 wires and shield for connection of...
  • Page 68: Connection Examples

    68/74 IRMA MATRIX R2 CAN Installation manual released 12.3 Connection examples 12.3.1 Installations with sCON-S (standard) for CAN Fig. 44, p. 69 shows a possible installation in a vehicle with 3 doors. The sensors are connected to the IRMA CAN BUS with the sCON-S for CAN. The IRMA gateway is located at the beginning of the CAN BUS.
  • Page 69: Fig. 44: Sensor Installation In A 3-Door Vehicle With Scon-S (Standard) For

    69/74 IRMA MATRIX R2 CAN Installation manual released Fig. 44: Sensor installation in a 3-door vehicle with sCON-S (standard) for CAN - IRMA gateway at the beginning (M12 connector) 1 Fuse 5 A, quick-acting 5 M12 H coupler of the CAN type, M12CAN-CON-03 M12 connector (male), CAN type 2 Power cable with M12 cnnector (f), type CAN/ 6 M12 extension cable, CAN type;...
  • Page 70: Fig. 45: Sensor Installation In A 4-Door Vehicle With Scon-S (Standard) For

    70/74 IRMA MATRIX R2 CAN Installation manual released Fig. 45: Sensor installation in a 4-door vehicle with sCON-S (standard) for CAN - IRMA gateway in the center (M12 connector) 1 Fuse 5 A, quick-acting 5 M12 H coupler of the CAN type, M12CAN-CON-03 M12 connector (male), CAN type 2 Power cable with M12 cnnector (f), type CAN/ 6 M12 extension cable, CAN type;...
  • Page 71: Fig. 46: Sensor Installation In A 3-Door Vehicle With Scon-F-12 - Irma Gateway At The Beginning (M12 Connector)

    71/74 IRMA MATRIX R2 CAN Installation manual released Fig. 46: Sensor installation in a 3-door vehicle with sCON-F-12 - IRMA gateway at the beginning (M12 connector) 1 Fuse 5 A, quick-acting 5 M12 H coupler of the CAN type; M12CAN-CON-03 M12 connector (male), CAN type 2 Power cable with M12 cnnector (f), type CAN/ 6 M12 screw plug;...
  • Page 72: Fig. 47: Sensor Installation In A 4-Door Vehicle With Scon-F-12 - Irma Gateway In The Center (M12 Connector)

    72/74 IRMA MATRIX R2 CAN Installation manual released Fig. 47: Sensor installation in a 4-door vehicle with sCON-F-12 - IRMA gateway in the center (M12 connector) 1 Fuse 5 A, quick-acting 4 IRMA gateway: IRMA-Gateway-x-XXXX M12 connector (male), CAN type 2 Power cable with M12 cnnector (f), type CAN/ 5 M12 H coupler of the CAN type, M12CAN-CON-03 2 wires and shield...
  • Page 73: Fig. 48: Can Installation In A 4-Door Articulated Vehicle (Direct Connection To The On-Board Computer, Second Power Supply On The Can Bus)

    73/74 IRMA MATRIX R2 CAN Installation manual released Fig. 48: CAN installation in a 4-door articulated vehicle (direct connection to the on-board computer, second power supply on the CAN BUS) 1 Fuse 5 A, quick-acting 6 M12 screw plug; M12CAN-CON-04 M12 connector (male), CAN type 2 Power cable with M12 cnnector (f), type CAN/ 7 sCON-S connector for MATRIX sensor on the CAN BUS;...
  • Page 74: Annex B Drilling Patterns

    Annex B Drilling patterns Important! After printout of the drilling template please check the reference dimension.
  • Page 75 Index Description of change Date Editor Approved Date Name iris-GmbH Creator 05.12.14 infrared & intelligent sensors 1 / 3 Page www.irisgmbh.de iris- Part-No. Production status Material Surface Unit Discription Scale A4-Format mm (inch) Drilling template IRMA MATRIX, Surface mount version...
  • Page 76 Drilling template for DIST500-A_00 Scale: 1:1 Printer setting: set option "Actual size"...
  • Page 77 Drilling templates for Surface mount version DIST500-A Scale: 1:1 Printer setting: set option "Actual size"...
  • Page 78 12±0.5 Index Description of change Date Editor Approved Date Name iris-GmbH Creator 05.12.14 infrared & intelligent sensors 1 / 4 Page www.irisgmbh.de iris- Part-No. Production status Material Surface Unit Discription Scale A4-Format mm (inch) Drilling template IRMA MATRIX, Surface mount with door contact...
  • Page 79 Drilling template for S-D500-A-DC Scale: 1:1 (reference dim.) Printer setting: set option "Actual size"...
  • Page 80 Drilling templates for IRMA MATRIX Surface mount with door contact DIST500-A-DC Scale: 1:1 (reference dim.) Printer setting: set option "Actual size"...
  • Page 81 153 (Kontrollmaß)
  • Page 82 28±0.5 Index Description of change Date Editor Approved Date Name iris-GmbH Creator 05.12.14 infrared & intelligent sensors 1 / 3 Page www.irisgmbh.de iris- Part-No. Production status Material Surface Unit Discription Scale A4-Format mm (inch) Drilling template IRMA MATRIX, Flush mount with threade bolt...
  • Page 83 Drilling template for BB_DIST500-E_00 Scale: 1:1 Printer setting: set option "Actual size"...
  • Page 84 Drilling templates for Flush mount with threaded bolt DIST500-E Scale: 1:1 Printer setting: set option "Actual size"...