Baxi Combi Instant 105e Gas Fired Wall Mounted Combination Boiler User’s Operating Instructions Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
Natural Gas Baxi Combi Instant 105e G.C.N 47 075 09 Baxi UK Limited is one of the leading manufacturers of domestic heating products in the UK. Our first priority is to give a high quality service to our customers. Quality is designed into every Baxi product - products which fulfil the demands and needs of customers, offering choice, efficiency and reliability.
Basingstoke. RG24 8WG. IN AN EMERGENCY If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves as follows; 1. Turn off the electrical supply and turn the selector switch on the facia box to the OFF position.
2.0 Introduction Introduction 1. Your Baxi Combi Instant 105e is a gas fired, room sealed, powered flue combination boiler, providing central heating for your home and mains fed domestic hot water to taps and shower. It is fully automatic and does not have a pilot light.
6. The boiler will light automatically on demand. 7. The orange burner on neon ( ) will illuminate when the boiler is operating and the main burner is on (Fig. 5). IMPORTANT: When the selector switch is in the ‘0’ (Off) position the electrical supply to the boiler is isolated.
(Fig. 12). 10. The flow rate can be reduced down to as low as 2.5 litre/min. The boiler will still recognise the need to heat the water. Flame Failure Reset 1. The red flame failure neon (...
Fig. 17 3.0 Operating the Boiler Safety Thermostat 1. Your Baxi Combi Instant 105e is fitted with an additional safety device, which shuts down the boiler in the event of the system or the boiler overheating. The safety thermostat neon ( light in this instance (Fig.
Central Heating System Pressure 1. The water pressure in the central heating system is indicated by the pressure gauge. 2. With the system cold and the boiler not operating the pressure should be between 0.5 and 1.0 bar. During operation the pressure should not exceed 2.5 bar, and will normally be...
4. The boiler may be installed in a cupboard if 200mm Min these minimum clearances are kept. The compartment should be large enough to house the boiler and ancillary equipment only.
(Fig. 25). Guarantee 1. Your Baxi Combi Instant 105e is designed and produced to meet all the relevant Standards. 2. Baxi UK Limited provide a 12 month guarantee on the boiler.
Page 11
Baxi UK Limited manufacture a comprehensive range of products for the domestic heating market. Gas Central Heating Boilers (Wall, Floor and Fireside models). Independent Gas Fires. Renewal Firefronts. Gas Wall Heaters. Solid Fuel Fires. If you require information on any of these products, please write, telephone or fax to the Sales Department.
Need help?
Do you have a question about the BAXI COMBI INSTANT 105E and is the answer not in the manual?
Questions and answers