QUICK START GUIDE
20 P PLASMA CUTTER
1.
Read user manual
2.

Connect to input air

• 60-100 PSI
• > 1.5 CFM
• Clean air
• No oil
• No moisture
Output air pressure is pre-set at the factory
3.

Connect to Input Power

120VAC, 20A
outlet, 30A breaker
recommended
• Generator OK with continuous
output > 4,000 W
• Extension cord: #12 AWG or
larger; 25' (8m) or shorter
OPERATING TIPS
Travel speed
FIND MORE PLASMA CUTTING TIPS AT WWW.ASKFORNEY.COM
Flashing green
Low input power
Verify power source is
120 VAC +/- 10%
4.

Drag tip on workpiece

Cutting capability
Will cut clean up to
1/4" (6.4 mm)
Too fast.Watch
spark trail angle.

TROUBLESHOOTING GUIDE

Solid yellow
Duty cycle exceeded
Allow machine to cool.
See manual.
QUESTIONS OR TROUBLE? Contact Forney Industries at 1-800-521-6038
customerservice@forneyind.com • askforney.com • forneyind.com
NOTE: Correct consumable assembly
Replace worn consumables
Replacement electrodes and cutting tips available in a 4-pack (2 ea.)
CAT# 85392
Flashing yellow
Low input air pressure
Ensure air input meets
pressure and flow
requirements.
+
Torch body
a.
Electrode
b.
c.
Air diffuser ring
d.
Cutting tip (0.65)
e.
Shield cup (two hole)
Flashing red
Consumables not in
place properly
Check consumable
assembly. Tighten cup. See
manual.
EN_v2-3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Easy Weld 20P and is the answer not in the manual?

Questions and answers

Summary of Contents for Forney Easy Weld 20P

  • Page 1 Verify power source is Allow machine to cool. Ensure air input meets Check consumable 120 VAC +/- 10% See manual. pressure and flow assembly. Tighten cup. See requirements. manual. QUESTIONS OR TROUBLE? Contact Forney Industries at 1-800-521-6038 customerservice@forneyind.com • askforney.com • forneyind.com EN_v2-3...
  • Page 2 Voir le manuel. consommables. Serrez le de pression et de 120 V en c.a. +/- 10 % bouchon. Voir le manuel. circulation d'air. DES QUESTIONS OU DIFFICULTÉS? Communiquez avec Forney Industries au 1-800-521-6038 customerservice@forneyind.com • askforney.com • forneyind.com FR_v2-3...
  • Page 3 120 V Consulte el manual. con los requisitos de la tapa. Consulte el CC +/- 10 % presión y flujo. manual. ¿TIENE ALGUNA PREGUNTA O PROBLEMA? Contacte a Forney Industries al 1-800-521-6038 customerservice@forneyind.com • askforney.com • forneyind.com SP_v2-3...

Table of Contents