Multimeter Command And Parameter Opcodes - HP E1351A User Manual

Fet multiplexer
Table of Contents

Advertisement

Multimeter
Command and
Parameter Opcodes
Multimeter
Command
Parameter
Measurement
04
Function
Range
02
Aperture Time
00
Autozero
08
Offset
36
Compensation
Trigger Source
06
Trigger Count
39
Trigger Delay
23
Voltmeter
40
Complete Signal
Destination
Sample Count
38
Sample Source
07
Sample Period
10
(5)
Software Sample
35
(6)
Trigger Arm
12
Trigger Immediate 13
Send Error
15
96 HP E1351A/53A Register-Based Programming
Table B-1 contains the multimeter command and parameter opcodes. The
opcodes used to query the parameter settings are also included.
Table B-1. Multimeter Command and Parameter Opcodes
Parameter
Opcode
Opcode
00
01
02
00
01
02
03
04
05
00
01
02
03
04
05
06
00
01
02
00
01
00
01
02
03 - 0A
<upper byte>
<middle byte>
<lower byte>
<upper byte>
<middle byte>
<lower byte>
8-bit binary number
(7)
<upper byte>
<middle byte>
<lower byte>
00
01
02
03
<upper byte>
<lower byte>
— -
00
01
— -
— -
Table B-1 Continued on Next Page
Value
Opcode
DCV
05
ACV
(4-wire) OHMS
125 mV / 256 Ω
03
1V / 2.048 kΩ
8V / 16.384 kΩ
64V / 131 kΩ
300V / 1.048 MΩ
Autorange
267 ms
01
16.7 ms
320 ms
20 ms
2.5 ms
100 µs
10 µs
On
09
Off
Once
Off
37
On
Immediate
29
External
Hold
TTL trigger lines
0 - 7
1 - 16,777,215
33
(1),(3)
0 - 16.777215s
31
(1)
0 - 7
41
(TTL trigger lines)
1 - 16,777,215
32
(1),(4)
Immediate
30
Timer
Software
Control Register
76µs - 65.534ms
11
(1)
— -
—-
Un-armed
—-
Armed
— -
—-
— -
—-
Query
Query
Response
parameter
opcode
parameter
opcode
parameter
opcode
parameter
opcode
parameter
opcode
parameter
opcode
24-bit unsigned
number
(2)
24-bit unsigned
number
(2)
8-bit binary number
24-bit unsigned
number
(2)
parameter
opcode
16-bit unsigned
number
(2)
...
— -
...
— -
Appendix B