Samsung SSA-P102 User Manual
Samsung SSA-P102 User Manual

Samsung SSA-P102 User Manual

Access control panel

Advertisement

Quick Links

Access Control Panel

user manual

imagine
Thank you for purchasing this Samsung product.
To receive more complete service,
please visit our website.
www.samsungsecurity.com
the possibilities
SSA-P102
SSA-P102T

Advertisement

Table of Contents
loading

Summary of Contents for Samsung SSA-P102

  • Page 1: User Manual

    Access Control Panel user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please visit our website. www.samsungsecurity.com SSA-P102 SSA-P102T...
  • Page 2: Safety Information

    If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in any way. (SAMSUNG is not liable for problems caused by unauthorized modifi cations or attempted repair.) . When cleaning, do not spray water directly onto parts of the product. Doing so may cause fi re or electric shock.
  • Page 3: Important Safety Instructions

    Keep out of direct sunlight and heat radiation sources. It may cause fi re. Install it in a place with good ventilation. Avoid aiming the controller directly towards extremely bright objects such as sun. Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall be placed on the apparatus.
  • Page 4: Table Of Contents

    contents PRODUCT INTRODUCTION INSTALLATION AND EXTERNAL CONNECTION INITIALIZATION TROUBLESHOOTING PRODUCT SPECIFICATIONS contents FeatureS What’s included Cable Selection Connecting the termination resistor and diode Earth-grounding the communication cables Power, Reader, and I/O Connection Communication Line Connection System Initialization Reader Input Bit Setup Board ID Setting Communication Speed Setup Troubleshooting...
  • Page 5: Features

    product introduction FEATURES This is a state-of-the-art single door access controller device that provides a high level security system in an affordable price, meeting the needs in the security industry. With its user-friendly interface, this product enables user manipulation easy and simple for whatever you want to perform in a high level of stability. With its user-friendly interface, it can register cards between 10,000 and 50,000, within which you can change, delete, and add them.
  • Page 6: What's Included

    product introduction Time Scheduling You can specify a time range during which a specifi c operation is performed. You can specify a specifi c time range for a schedule code, which will be transferred to the applicable device. You can specify up to 5 different time ranges for a day, ranging from Monday to Sunday including holidays.
  • Page 7 Main Board Used to attach SSA-P102 to the closure using a metal supporter. (Ensure that you use Fixing Hole the metal supporter to prevent the EMI.) 2Pin DIP Switch Used to set the type of a connected reader to either 26bit Wiegand or 34bit Wiegand.
  • Page 8 BUZZER buzzer control settings. LCD Connection Port Optional item. Keypad Connection Port Optional item. Power Connection Port SSA-P102 uses DC +12V for its power source. TTL Output #1 TTL output port. TTL Output #2 TTL output port. Relay Output #1 Relay output port.
  • Page 9: Cable Selection

    Input This product Door Lock Alarm Device Lock (Alarm) This product RS-232 Cable Converter Host P.C. RS-485 Cable SSA-P102 SSA-P102 SSA-P102 Converter RS-422 Cable SSA-P102 SSA-P102 SSA-P102 Converter  The cables should be thick enough to allow the maximum current consumed by the reader.
  • Page 10: Connecting The Termination Resistor And Diode

    To reduce this surge, it is recommended to connect a bypass diode to the relay. SSA-P102 installation and external connection RS-485 RS-485 Termination Resistors RS-422 RS-422 Termination Resistors Cathode 1N4004 ~ 1n4007 or equiv. Lock/Alarm 120Ω Last SSA-P102 120Ω Last SSA-P102 Anode...
  • Page 11: Earth-Grounding The Communication Cables

    RS-422 Cable RS-422/RS-232 Converter Communication RS-232 Wires ShieldWire Connect Open RS-422 HOST PC RS-422 RS-422 RS-422 Earth Ground or Chasis Ground or Power Ground SSA-P102 #1 SSA-P102 #2 SSA-P102 #3 SSA-P102 #n English _ 11...
  • Page 12: Power, Reader, And I/O Connection

    installation and external connection POWER, READER, AND I/O CONNECTION Power Connection Check the location of the power port. - Connect the plus (+) line of DC 12V to the corresponding port (+12V). - Connect the plus (-) line of DC 12V to the GND (-) port. Reader Connection BLACK READER #2...
  • Page 13 Input Connection INPUT #5 INPUT #4 INPUT #3 Door Contact INPUT #2 Exit Button INPUT #1 - The Input #1 and Input #2 ports have the Exit button and the Door Contact Sensor installed, while Input #3 to Input #5 can be confi gured to your preference. - Exit Button Connection Connect one line of the Exit button to IN 1.
  • Page 14 installation and external connection Output Connection - According to the operation mode, the Door Lock type is classifi ed in two: NC (Normal close) and NO (Normal Open). Make the connection as appropriate. - To prevent a risk of voltage surge during the lock operation, it is recommended to use the bypass diode. - If the Door Lock type is POWER FAIL SAFE Connect the COM (common) line of the Door Lock relay to DC +12V.
  • Page 15: Communication Line Connection

    COMMUNICATION LINE CONNECTION RS-232 Communication Port Connection A 9-pin connector for serial communication is required to make connection to the PC. Connect the 9 pin connector for RS-232 communications as follows: HOST PC RS-232 9-Pin Female Connector Connect RS-232-TX to pin #2 of the 9-pin connector. Connect RS-232-TX to pin #3 of the 9-pin connector.
  • Page 16 installation and external connection RS-422 Communication Port Connection (Standalone) The RS-422/RS-232 converter is required to establish RS-422 communications. Connect the 9-pin connector of the RS-422/RS-232 converter as follows: RS-422/RS-232 Converter Power T+ T- R+ R- Connect RS-422-TX(-) to the RX(-) port of the converter. Connect RS-422-TX(+) to the RX(+) port of the converter.
  • Page 17 RS-422 Communication Port Connection (Multiple Units) The RS-422/RS-232 converter is required to establish RS-422 communications with SSA-P102. RS-422/232 Converter RS-232C Power T+ T- R+ R- - Follow the guidelines below to make connection between devices. Connect TX(-) of one device to TX(-) of other one.
  • Page 18 installation and external connection TCP/IP Communication Port Connection 1) TCP/IP Communication Connection TCP / IP  SSA-P102T is required to establish TCP/IP communications. 2) Cabling Connect the LAN cable to the TCP/IP RJ-45 jack as shown. Connect the RJ45 jack of the unit to the RJ45 plug, the LAN cable of the network system. Set a unique communication address (COMM ADDR) for each unit Install and launch the application (SAMS).
  • Page 19: System Initialization

    Initialization SYSTEM INITIALIZATION Initializing the system using the Initialize switch Apply the power and initialize the system by using the initialization switch. Locate the Initialize switch ( and press both switches simultaneously. • Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep.
  • Page 20: Board Id Setting

    initialization BOARD ID SETTING Each device in the multi-serial communication connection is assigned with a unique number to identify each other. The initial value of the switch is “0”, and all of the 8 switches are defaulted to OFF. Each switch has a unique value, and the board ID is the sum of the values of the switches.
  • Page 21: Troubleshooting

    TROUBLESHOOTING If the product does not function properly, please see the below for trouble shooting. If the trouble persists, please contact the SAMSUNG Customer Service near you. Problem Can I specify RF only or RF+P/W mode differently according to the card?
  • Page 22 (A different power source may be fi ne but the earth-grounding point should be connected to GND of the device.) If you fi nd the output signal from SSA-P102 but with severe noise when using a measuring device to measure the Wiegand communication line, please check the followings: - Connect the shield wire and the spare wire of the cable to GND.
  • Page 23: Product Specifi Cations

    0°C to +50°C Operating Humidity 10% to 90% relative humidity non-condensing Color / Material Black/ PCB Dimension 137 x 137 x 18 (W x H x D(mm)) Weight 160g SSA-P102 RS232 / RS422 / RS485 / TCP/IP 170g SSA-P102T English _ 23...
  • Page 24 Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life.

This manual is also suitable for:

Ssa-p102t

Table of Contents