Homentry HERDO1 Installation And Operating Manual

Homentry HERDO1 Installation And Operating Manual

Rolling garage door opener

Advertisement

H H E E R R D D O O 1 1
R R o o l l l l i i n n g g G G a a r r a a g g e e D D o o o o r r O O p p e e n n e e r r
I I n n s s t t a a l l l l a a t t i i o o n n a a n n d d O O p p e e r r a a t t i i n n g g G G u u i i d d e e
T T h h i i s s m m a a n n u u a a l l i i n n c c l l u u d d e e s s I I M M P P O O R R T T A A N N T T S S A A F F E E T T Y Y i i n n f f o o r r m m a a t t i i o o n n
D D O O N N O O T T P P E E R R F F O O R R M M T T H H E E I I N N S S T T A A L L L L A A T T I I O O N N B B E E F F O O R R E E R R E E A A D D I I N N G G T T H H E E G G U U I I D D E E
T T H H O O R R O O U U G G H H L L Y Y

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HERDO1 and is the answer not in the manual?

Questions and answers

phil deacon
March 4, 2025

The manual pull cord on the motor does not disengage the roll from the motor so can't be used manually

1 comments:
Mr. Anderson
March 4, 2025

To fix the manual pull cord issue on the HomEntry HERDO1 motor that prevents it from disengaging, pull the release cord down firmly to re-engage the door. If the problem persists, check for obstructions or mechanical issues in the release mechanism. Ensure the system is properly adjusted and functioning as intended.

This answer is automatically generated

John Malfiore
March 14, 2025

How to program motor when it’s fitted on the left

1 comments:
Mr. Anderson
March 14, 2025

To program the Homentry HERDO1 motor for left-hand installation:

1. Ensure the opener is plugged in and turned on.
2. Confirm the door is clear of obstructions and hands are away from moving parts.
3. The HERDO1 opener is factory set for right-hand installation, so it must be changed for left-hand operation.
4. Refer to the control panel diagram in section 4 to locate the program buttons and LEDs.
5. Follow the steps in the manual to switch the operation mode to left-hand.
6. The courtesy light will flash at half strength during programming.
7. An audible beep will confirm each button press.
8. Once configured, set the travel limits to ensure the door moves the correct distance up and down.

Refer to the diagrams in the manual for guidance.

This answer is automatically generated

Summary of Contents for Homentry HERDO1

  • Page 1 H H E E R R D D O O 1 1 R R o o l l l l i i n n g g G G a a r r a a g g e e D D o o o o r r O O p p e e n n e e r r I I n n s s t t a a l l l l a a t t i i o o n n a a n n d d O O p p e e r r a a t t i i n n g g G G u u i i d d e e T T h h i i s s m m a a n n u u a a l l i i n n c c l l u u d d e e s s I I M M P P O O R R T T A A N N T T S S A A F F E E T T Y Y i i n n f f o o r r m m a a t t i i o o n n D D O O N N O O T T P P E E R R F F O O R R M M T T H H E E I I N N S S T T A A L L L L A A T T I I O O N N B B E E F F O O R R E E R R E E A A D D I I N N G G T T H H E E G G U U I I D D E E...
  • Page 2 Warranty Registration Register your warranty at: www.homentry.com.au/warranty www.homentry.co.nz/warranty...
  • Page 3: Table Of Contents

    START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS WARNING • Failure to comply with the following instructions may result in serious personal injury or property damage. • Read and follow all instructions carefully. • The garage door opener is designed and tested to offer safe service provided it is installed and operated in strict accordance with the instructions in this manual.
  • Page 4: Carton Inventory

    13 mm, 10 mm, 8 mm 5.5 mm DOOR REQUIREMENTS The HERDO1 is suitable for spring balanced Residential Rolling garage doors with: • Maximum door height of 4.5 m • Maximum curtain area of 10.5 m • Maximum door mass of 60 kg The obstruction detection beams must be installed if the force at the edge of the closing door exceeds 400 N (40 kgf).
  • Page 5: Control Panel

    CONTROL PANEL 1. Terminal Block: used for external accessories (see chart below). Colour Polarity Comment No Function Push button Dry contact input for push button wired wall controls: White Common Common terminal for push button, obstruction detection beams & accessory power: 2 Common White Common terminal for push button, IR Beam &...
  • Page 6: Operating Manual Release

    THE RELEASE HANDLE & CORD DO NOT DISENGAGE THE OPENER TO MANUAL OPERATION WITH CHILDREN , PERSONS OR OTHER OBJECTS INCLUDING MOTOR VEHICLES WITHIN THE DOORWAY: (The door is under significant tension and if the door has developed a fault or incorrect tension, it P Arrow may be unsafe and may fall rapidly.) utton...
  • Page 7: Prepare & Test The Door

    TESTING THE DOOR Complete the following test to ensure your door is well balanced, and not sticking or binding: • Disable all locks and remove any ropes connected to the garage door. • Lift the door to about halfway and then release it. The door should remain spring balanced.
  • Page 8: Pinning The Door

    PINNING THE DOOR Note: A ballooning door may delay the safety reversal response and can compromise garage door security. • To remedy any ballooning, insert the supplied self tapping metal screws (inset 3) into where the curtain leaves the roll. Free curtain Ballooning Add fasteners here...
  • Page 9: Installation Procedure

    Ladder INSTALLATION PROCEDURE Do not allow people to walk under or around the door during the installation process as serious injury can occur. NOTE: The opener can be installed on either side of the door. The following instructions are for Rope RIGHT HAND INSTALLATIONS (as illustrated i.e.
  • Page 10: Adjustment & Testing

    Courtesy light: during the programming sequence, the courtesy light will flash at half strength. NOTE: The HERDO1 opener is factory configured for right hand installation. The opener will operate during this procedure. Make sure the door is clear of obstruction.
  • Page 11: System

    TESTING THE SAFETY REVERSE SYSTEM The safety reverse system test is important. The garage door must reverse on contact with a 40 mm obstacle laid flat on the floor. Failure to properly adjust the opener may result in serious personal injury from a closing garage door.
  • Page 12 SAFETY FIRST! B. Twist like coloured Whilst HomEntry have engineered safety features into your garage door opener, we urge you to consider fitting wires together obstruction detection beams to your new garage door opener. In many countries these devices are compulsory to assist in preventing serious injury or property damage.
  • Page 13: Audible Beep

    AUDIBLE BEEP (OPTIONAL) The HERDO1 has been factory set for Audible “BEEP”. The Audible beep can be turned OFF by using the following method. • Start with the door fully CLOSED. Flash x 2 • Press and Hold both “S” and “DN” buttons...
  • Page 14: Wireless Programming

    WIRELESS PROGRAMMING (OPTIONAL ACCESSORIES) Activate the opener only when door is in full view, free of obstruction and properly adjusted. No one should enter or leave garage while door is in motion. Do not allow children to operate push button(s) or remote(s). Do not allow children to play near the door. NOTE: The transmitter(s) supplied with your opener are preprogrammed by the factory.
  • Page 15: Operating Your Opener

    To re-engage the door, pull the release cord down firmly. The opener light will turn on for 3 minutes when the opener is activated. SPECIAL NOTE: HomEntry strongly recommends that obstruction detection beams be installed on all garage door openers.
  • Page 16: Wiring

    TYPICAL WIRING DIAGRAM HERDO1 Information for Service Personnel green (4) grey (3) white (2) red (1) External Receiver 24 vdc white white/black Wired Wall Button IR Beams Battery of the remote control: REPLACE BATTERIES IN REMOTES The batteries in the remote have an extremely long life.
  • Page 17: Troubleshooting

    TROUBLESHOOTING 1. The opener will not operate from either the 7. Door reverses for no apparent reason and • Check the obstruction detection beams (if you have UP/DOWN ACTIVATION button or the transmitters : opener lights flashes 10 times: installed this accessory). If the red light on the beam is •...
  • Page 18: Diagnostic Chart

    DIAGNOSTIC CHART Your garage door opener is programmed with self-diagnostic capabilities. The indicator LEDʼs 1 & 3 on the control panel will flash a number of times to indicate a fault code exists. DIAGNOSTIC CODE SYMPTOM POSSIBLE RESOLUTION LED 1 LED 3 The garage door opener will not Safety sensors are open circuit or wires may be cut.
  • Page 19: Warranty

    Warranty Registration Register your warranty at: www.homentry.com.au/warranty www.homentry.co.nz/warranty...
  • Page 20 Unit to you. HomEntry are committed to manufacturing and supplying high quality This HomEntry Warranty does not cover any failure of, or defect in, the Unit goods. As part of this commitment, we seek to provide reliable service due to:...

Table of Contents

Save PDF