Controller for magnetically levitated pumps (79 pages)
Summary of Contents for Adixen ACP 15
Page 2
Thus, whatever the circumstances, the users of Adixen products can always rely on quick support of our specialists in Vacuum Technology. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 3
ACP 15 G, ACP 28 G, ACP 40 G DRY PRIMARY PUMPS FOR THE maintenance on your PUMPING OF CORROSIVE GAS TRACES. pump. FEATURES: MULTI-STAGE ROOTS TECHNOLOGY UNIVERSAL SINGLE PHASE ELECTRICAL SUPPLY AIR COOLED Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 4
Alcatel Vacuum Technology France. Specifications and information are subject to change without notice by Alcatel Vacuum Technology France. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Indicates a potentially hazardous situation which, if not avoided, could result in moderate or minor injury. It may also be used to alert against unsafe practices. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 6
General contents 112369 MANUAL REFERENCE: 02 - June 2008 EDITION: ACP Series User's Manual Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 7
■ 2 pump models according to different applications - standard version, - G version. ■ Thermal protection based on temperature sensors. ■ RS 485 Serial link Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 8
ACP Series dry primary pump overview Model ACP 15 / 15 G overview Model ACP 28 / 28 G / 40 / 40 G overview...
Thus avoiding condensation of pumped gases into the pump. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 10
This pump model can be used in condensable gas applications such as: • Process monitoring. • Load lock pumping. • Transfer chamber pumping. • Focused Ion Beams. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
(1)Typical value obtained after minimum 1 hour of pump warm up time. (2)Relative nitrogen pressure 300 mbar. (3)Oil charge has been introduced into oil casing at factory. Don't modify this oil level. Alcatel Vacuum Technology France - User's manual ACP 15 /28 /40 Series 2...
Page 13
A 40 Technical characteristics - ACP 15 / ACP 15 G Gravity center and weight distribution Right wiew Front view Alcatel Vacuum Technology France - User's manual ACP 15 /28 /40 Series 2...
Page 14
Maximum loads on ground & seismic fixations We strongly advise you to secure the pump on the tool with 4 M6 x20 screws (2 screws per fixation plate minimum recommended). Screw material must comply with foot load specifications given in the table below.
Page 15
Typical value obtained after minimum 1 hour of pump warm up time. (2) Relative nitrogen pressure 300 mbar. (3) Oil charge has been introduced into oil casing at factory. Don't modify this oil level. Alcatel Vacuum Technology France - User's manual ACP 15 /28 /40 Series 2...
Page 17
Technical characteristics - ACP 28 / 28 G / 40 / 40 G Gravity center and weight distribution Front view Right wiew Alcatel Vacuum Technology France - User's manual ACP 15 /28 /40 Series 2...
Page 18
Maximum loads on ground & seismic fixations We strongly advise you to secure the pump on the tool with 4 M6 x20 screws (2 screws per fixation plate minimum recommended). Screw material must comply with foot load specifications given in the table below.
Page 19
A 50 Accessories Inlet filter Exhaust silencer Frequency converter interface plug Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 20
It is compatible with ACP15, ACP28 and ACP40 pump models. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
B 00 Safety instructions Installation - Start up (ctd) Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series...
Page 23
B 00 Safety instructions Installation - Start up (ctd) Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 24
Safety instructions Operation (ctd) Contact in case of emergency Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 25
B 00 Safety instructions Pump labels Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
(new pump as well as used). For this contact your local service center (address of the main contacts at the rear of the manual). Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 27
Installation of ACP Series pumps Ventilation Vents at both ends of the pump. Place the pump at least 80 mm from the stationary section. The ambient air temperature particularly near the fan must be less than 40°C. Installation safety The performance of the pump depends on the type of accessories used and instructions the quality of the mechanical connection.
When the pump is connected to the pumping line, it is essential to perform a leak test on the whole line to check the connection (pump, pipe,...). Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
The user supplied certified branch fuse should be in close proximity to the pump (no further than 7m (25 ft) within line of sight of the pump). Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
■ A 6 A circuit breaker is recommended for high voltage, 230 VAC + 10 %. ■ A 12 A circuit breaker is recommended for low voltage, 110 VAC + 10 %. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Used by means of dry contacts: - Rotation speed remote control according to the table below: ( 0 = open, 1 = closed): Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 32
B 40 Remote control connector wiring Wiring of the remote S1, 53, 54 and 55 are inputs. control plug S2 is an output (open collector) start/stop 52 closed: pump at speed 53, 54, 55: rotational speed selection Pin 8, 10, 12 and 14 are connected to the ground of the control unit.
Page 33
(«off-state») and Vout = Vcc. This circuit can not be used for power transfer. For switching of power circuits an amplification stage is required. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Wiring of the unit at the end of the line, when there is one and only unit in the link. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 35
■ For optimum ball bearing protection, the neutral gas pressure must be set to 0.3 bar (relative pressure) according to the flowrate value given in the table below: Nitrogen flowrate adjustment Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
- when the Start/Stop is made by RS485 serial link, the speed corresponds to the speed set point defined on serial link. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 37
1 hour with gas ballast opened. Put the main switch on «0» position or press the circuit breaker of the customer's installation. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 38
(x) and software release (zz). Ex : #004,ACP28— V1.03: product address 004 controls ACP 28 with a software release V1.03. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 39
Switches the speed set point to the nominal speed value #adrNSP<CR>[LF] Syntax This command allows to restore the nominal speed to the default value : (80 Hz for ACP 28/40 and 100 Hz for ACP 15). Result #adr,ok Defines the speed set point in stand-by mode Syntax #adr RPM nnnn<CR>[LF]...
Page 40
(since first start up), codified on 4 decimal figures (eg: operating time 4568 hours: tttt = 4568). Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
The full overhaul must be performed by manufacturer's trained personnel. Contact nearest service center or the service support at the following e-mail address: support.service@adixen.fr Performed by the manufacturer Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
The outside covers of the pump can be clean with a fluffy free duster. Use a cleaning product avoiding to damage the cover paint and stickers. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 43
Do not dispose of residue, if necessary, have it destroyed by a qualified organization. Oil drain. The oil drain is performed during pump overhaul by manufacturer's trained personnel. Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 44
Close the inlet and exhaust pipe of the pump with the following connecting accessories (avalaible in manufacturer's catalog): How us to contact The full overhaul must be performed by manufacturer trained personnel. Contact manufacturer nearest service center or the service support at the following e-mail address: support.service@adixen.fr...
Page 48
74009 ANNECY France ISO 9001 CERTIFIED declare under our sole responsibility that the following products : ACP 15 - ACP 15G ACP 28 - ACP 28G ACP 40 - ACP 40G to which this declaration relates are in conformity with the following European Directives...
Page 49
G 101 52 SEMI Certificate Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2...
Page 50
. Gases (or substances) that may possibly be formed inside the pump (due to a thermodynamic or chemical reaction, condensation, deposition, precipitation, etc.) (C). • Precautions need to be taken before transferring contaminated products. Please contact Service Center for recommendations. Alcatel Vacuum Technology France - User's Manual - ACP 15 / 28 / 40 Series 2...
Page 51
G 200 SAFETY QUESTIONNAIRE QUESTIONNAIRE DE SECURITE - Ce questionnaire est telechargeable sur le site : www.adixen.com This questionnaire can be downloaded from: www.adixen.com Procedure de retour des produits ADIXEN (Ce formulaire ne peut etre rempli et signs que par une personne habilitee)
Need help?
Do you have a question about the ACP 15 and is the answer not in the manual?
Questions and answers