14. spare parts kits....................15 1293 DoP No: 075 1293 - CPR - 0510 Teletek Electronics JSC, 14 Srebarna Str., 1407 Sofia, Bulgaria EN 54-2:1997/A1:2006/AC:1999; EN 54-4:1997/A2:2006/AC:1999 MAG2/4 Intended for use in fire detection and fire alarm systems in and around buildings.
The manufacturer shall not accept any product, of which no prior notice has been received via the RAN form at: http://www.teletek-electronics.com/en/support/Service The setup and programming included in the technical documentation shall not be regarded as defects. Teletek Electronics bears no responsibility for the loss of programming information in the device being serviced.
Note: This indication is not visible for the user. To examine the technical troubles in the system, the engineer has to remove the front cover of the box. Switch for changing over between Access Levels 1 and 2 - see item 1.6. Fire Control Panel MAG2/4 - User Manual...
Battery charger fault. ○ AUX Auxiliary supply fault. ○ Earth Short circuit to earth. Battery Low, Battery Lost and Charger LEDs are lighting up together in case of overload of the battery charger output. Fire Control Panel MAG2/4 - User Manual...
Access Level 2 - all buttons at the front panel are active. * NOTE: Fault conditions will not be announced instantly. There will be a short delay which will vary from condition to condition. Faults when cleared will automatically reset at the panel. Fire Control Panel MAG2/4 - User Manual...
• Position the battery in an upright position and place the temperature sensor behind it. • Close the outer cover using the nuts and screws from the spare parts kit: Fire Control Panel MAG2/4 - User Manual...
If General Fault and zone 1 FAULT LED’s illuminate, there is a wiring/ connection problem. Check the polarity of the connection, the connection of the devices and whether a head is removed. Check the EOL proper polarity and position. Fire Control Panel MAG2/4 - User Manual...
CC (Class Change) clamps of the main module terminal. The working mode of the sounders will be: - when the switch is pressed - one second sounder on, one second sounder off; - when the switch is depressed - the sounder is off. Fire Control Panel MAG2/4 - User Manual...
ZONE 1 is disabled. • Press TEST/ SCROLL, until The SOUNDER FAULT/DISABLE LED will start you reach the last zone in the blinking. system: The SOUNDER FAULT/DISABLE LED lights up • Press ENABLE/ DISABLE: permanently. Fire Control Panel MAG2/4 - User Manual...
Continue the system testing by pressing the “TEST/ SCROLL” button. The exit from the “One Man” Test mode is automatic after the end of the test procedure in the last Zone 4, or at any time by pressing “RESET” button. Fire Control Panel MAG2/4 - User Manual...
9. Technical Specifications of MAG2 and MAG4 Zones: • MAG 2 - 2 fixed zones • MAG 4 - 4 fixed zones Maximum number of detectors per zone: • Up to 20 (or 32 SensoMAG series) conventional detectors and unlimited number of manual call points.
12. service Record Date Visit Faults signature of Next Due Zones Completed Rectified Engineer Tested 1 2 3 4 Name: 1 2 3 4 Name: 1 2 3 4 Name: 1 2 3 4 Name: Fire Control Panel MAG2/4 - User Manual...
13. Fire Alarm Event LOG FAULT ACTION FIRE ZONE DATE TIME yes/no and Name yes / no number TAKEN TYPE 14. spare Part Kits Fire Control Panel MAG2/4 - User Manual...