ESAB Origo MA24 Instruction Manual
Hide thumbs Also See for Origo MA24:

Advertisement

Origo™
MA23                                              
MA24
Instruction manual
Valid for: from program version 1.81H
0460 454 401 GB 20170131

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Origo MA24 and is the answer not in the manual?

Questions and answers

Summary of Contents for ESAB Origo MA24

  • Page 1 Origo™ MA23                                               MA24 Instruction manual Valid for: from program version 1.81H 0460 454 401 GB 20170131...
  • Page 2: Table Of Contents

    WELDING DATA MEMORY ................15 FAULT CODES ....................16 List of fault codes..................Fault code descriptions ................ORDERING SPARE PARTS ................18 WIRE AND GAS DIMENSIONS................ORDERING NUMBERS ..................Rights reserved to alter specifications without notice. 0460 454 401 © ESAB AB 2017...
  • Page 3: Introduction

    Setting of the parameter shown in the MIG/MAG and MMA display The measured value in the display for arc voltage V and welding current A, is the arithmetic average value = rectified average value. 0460 454 401 - 3 - © ESAB AB 2017...
  • Page 4: Control Panel Ma24

    The measured value in the display for arc voltage V and welding current A, is the arithmetic average value = rectified average value. Symbol reference MIG/MAG welding method MMA welding method Synergy setting QSet™ setting Manual setting Creep start 0460 454 401 - 4 - © ESAB AB 2017...
  • Page 5 Setting voltage / QSet™ Gas purging Wire feed speed or Wire inching (Meaning of symbol differs Crater filling time depending on context.) Inductance Synergy selection VRD (Voltage Reducing Device) Voltage Current Percent Seconds 0460 454 401 - 5 - © ESAB AB 2017...
  • Page 6: Mig/Mag Welding

    These functions cannot be changed while welding is in progress Symbol and function explanation MIG/MAG welding MIG/MAG welding melts a continuously supplied filler wire, with the weld pool being protected by shielding gas. 0460 454 401 - 6 - © ESAB AB 2017...
  • Page 7 See the different synergic lines in section "Wire and gas dimensions". It is also possible to order other synergy lines, but these must be installed by an authorised ESAB service engineer. When activating synergy also select synergy option using the setting knob.
  • Page 8 Settings are made from the remote control unit. The remote control unit must be connected to the remote control unit socket on the equipment before activation. When the remote control unit is activated the panel is inactive. 0460 454 401 - 8 - © ESAB AB 2017...
  • Page 9: Hidden Mig/Mag Functions

    (16) appearing in the display and welding cannot be started whilst the error message is displayed. Contact an authorised ESAB service technician to activate the function. Gas purging Gas purging is used when measuring the gas flow or to flush any air or moisture from the gas hoses before welding starts.
  • Page 10 Creep starting feeds out the wire at 50% of the set speed until it makes electrical contact with the workpiece. Memory positions for trigger data This function gives the possibility to select whether to use trigger data between 2 or 3 programs. 0460 454 401 - 10 - © ESAB AB 2017...
  • Page 11 Start parameter R enables finetuning of the electric arc during the start moment when welding. The parameter can be set from 8.0 to 60.0, in steps of 0.25. This parameter can only be set in manual mode. 0460 454 401 - 11 - © ESAB AB 2017...
  • Page 12: Mma Welding

    If the VRD function is activated and the open-circuit voltage exceeds the 35 V limit, this is indicated by an error message (16) appearing in the display and welding cannot be started whilst the error message is displayed. Contact an authorised ESAB service technician to activate the function.     0460 454 401 - 12 - ©...
  • Page 13: Hidden Mma Functions

    If for instance the set weld current is 100 A and the Hot start amplitude is set to 10 %, the weld current during the hot start time will be 110 A. 0460 454 401 - 13 - © ESAB AB 2017...
  • Page 14 If the max current is 100 A and the min current is to be 50 A, set the concealed function min current to 50 %. If the max current is 100 A and the min current is to be 90 A, set the min current to 90 %. 0460 454 401 - 14 - © ESAB AB 2017...
  • Page 15: Welding Data Memory

    To switch between the different welding data memories press button The welding data memory has a back-up battery so that the settings remain even if the equipment has been switched off. 0460 454 401 - 15 - © ESAB AB 2017...
  • Page 16: Fault Codes

    The power unit / wire feed unit has lost contact with the control panel. Action: Check the equipment and ensure that only one wire feed unit or remote control unit is installed. If the fault persists, send for a service technician. 0460 454 401 - 16 - © ESAB AB 2017...
  • Page 17 Action: Connect the control panel to a power source of the same type as the one last connected or configure the control panel for the appropriate type of power source. 0460 454 401 - 17 - © ESAB AB 2017...
  • Page 18: Ordering Spare Parts

    6 ORDERING SPARE PARTS ORDERING SPARE PARTS Spare parts and wear parts can be ordered through your nearest ESAB dealer, see the back cover of this document. When ordering, please state product type, serial number, designation and spare part number in accordance with the spare parts list. This facilitates dispatch and ensures correct delivery.
  • Page 19: Wire And Gas Dimensions

    WIRE AND GAS DIMENSIONS WIRE AND GAS DIMENSIONS Synergic lines 0460 454 401 - 19 - © ESAB AB 2017...
  • Page 20: Ordering Numbers

    Denomination 0459 773 889 Control panel Origo™ MA23 0459 773 886 Control panel Origo™ MA24 0459 839 024 Spare parts list Technical documentation is available on the Internet at: www.esab.com 0460 454 401 - 20 - © ESAB AB 2017...
  • Page 21 ORDERING NUMBERS 0460 454 401 - 21 - © ESAB AB 2017...
  • Page 22 ESAB subsidiaries and representative offices Europe THE NETHERLANDS North and South America SOUTH KOREA ESAB Nederland B.V. ESAB SeAH Corporation AUSTRIA Amersfoort ARGENTINA Kyungnam ESAB Ges.m.b.H Tel: +31 33 422 35 55 CONARCO Tel: +82 55 269 8170 Vienna-Liesing Fax: +31 33 422 35 44...

This manual is also suitable for:

Origo ma23

Table of Contents

Save PDF