E.T. Systems Drive 500 User Instructions

E.T. Systems Drive 500 User Instructions

500kg slide gate operators
Hide thumbs Also See for Drive 500:

Advertisement

ET DRIVE 500/600 USER 2016.001.001
End User Instruc ons
High Traffi c
Low Traffi c
500kg Slide Gate Operators
Designed, manufactured and
supported by ET NICE (Pty) Ltd
ET
Nice
www.et.co.za

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Drive 500 and is the answer not in the manual?

Questions and answers

christopher
April 10, 2025

clear an alarm code

1 comments:
Mr. Anderson
April 10, 2025

To clear an alarm code on the E.T. Systems Drive 500, the alarm condition must be resolved. For a gate jammed open alarm, the gate must be closed to reset the alarm. For a gate forced open alarm, the gate must be returned to the secured closed position to reset the alarm. The alarm will automatically reset once the gate is back in its normal closed and secured position.

This answer is automatically generated

Summary of Contents for E.T. Systems Drive 500

  • Page 1 ET DRIVE 500/600 USER 2016.001.001 End User Instruc ons High Traffi c Low Traffi c 500kg Slide Gate Operators Designed, manufactured and supported by ET NICE (Pty) Ltd Nice www.et.co.za...
  • Page 2 Introduc on. Page 3 Be Safe! Instruc ons, warnings and obliga ons. Page 4 Technical specifi ca ons. Page 5 How to use the manual override. Opera ng mode defi ni ons and examples. Page 6 Collision sensing and safety overload rou nes. Page 7 Safety infra-red beams func on.
  • Page 3 Be Safe! WARNING!! These are the general safety obliga ons for the installers and users of ET Systems automa on equipment. Only suitably qualifi ed persons, may install, repair or service the product. Unless expressly indicated in the user instruc ons, no user serviceable components can be found inside any ET Systems automa on product.
  • Page 4 Before removing the ba ery from the system the household mains must be disconnected. In the case of the motor unit being removed and scrapped, the ba ery must be removed fi rst. Technical specifi ca ons. TECHNICAL SPECIFICATIONS Technical Data Drive 500 Drive 600 Rated gate mass. 500kg 500kg Maximum gate travel.
  • Page 5 How to use the manual override. Move gate open and closed by hand To disengage the gearbox (Manual mode) To disengage the gearbox (Manual mode) (Manual mode) Raise lock cover. Swing the manual override lever 90 Manoeuvre the gate by hand. Insert the key.
  • Page 6 Collision sensing and safety overload rou nes. Basic opera ng features. In the case of the gate colliding with an obstruc on such as a person passing through the entrance way, the collision sensing will automa cally detect the collision and the system will run a safety overload rou ne. Safety overload rou ne while gate is opening.
  • Page 7 Safety infra-red beams func on. Basic opera ng All modes except P.I.R.A.C. features If the safety beam input has been switched on, the control card will constantly monitor to ensure a set of safety beams is installed. NB! If the BT input mode has been set to either simple auto-close or condominium mode, the safety beam input is required. Below is an example of how the gates will behave whenever the safety beam input is ac vated.
  • Page 8: Standard Mode

    “BT” Bu on triggers. Basic opera ng features Standard mode. The BT func ons are the primary full gate opening func ons for motor vehicle access. There are two ways of ac va ng the “BT” func ons on this control card. Either via the hardwired BT input or the BT receiver channel. In Standard mode the gates respond to each BT trigger.
  • Page 9 “BT” Bu on triggers. Basic opera ng Simple auto-close mode. features The BT func ons are the primary full gate opening func ons for motor vehicle access. There are two ways of ac va ng the “BT” func ons on this control card. Either via the hardwired BT input or the BT receiver channel. Simple auto-close mode func ons exactly the same as standard mode except that the gates will close automa cally a er the programmed BT au- to-close mer has med out.
  • Page 10 “BT” Bu on triggers. Basic opera ng features Condominium auto-close mode. The BT func ons are the primary full gate opening func ons for motor vehicle access. There are two ways of ac va ng the “BT” func ons on this control card. Either via the hardwired BT input or the BT receiver channel. In Condominium auto-close mode, all BT triggers are treated as open, keep opening, keep open or re-open triggers.
  • Page 11 “BT” Bu on triggers. Basic opera ng P.I.R.A.C. auto-close mode. features The BT func ons are the primary full gate opening func ons for motor vehicle access. There are two ways of ac va ng the “BT” func ons on this control card. Either via the hardwired BT input or the BT receiver channel. In P.I.R.A.C.
  • Page 12 “PED” Pedestrian trigger. Basic opera ng features (With no safety beams installed) The PED trigger is a higher security op on and is used when access to or from the property is limited to exclude motor vehicles. In the case of no safety beams being installed then the pedestrian auto-close func onality is disallowed for safety. If the Loop or the BT triggers are ac vated at any me during the pedestrian rou ne, the gate will open to the full open posi on and the pedestrian transac on is cancelled.
  • Page 13 “PED” Pedestrian trigger. Basic opera ng (With safety beams installed) features The PED trigger is a higher security op on and is used when access to or from the property is limited to exclude motor vehicles. If the safety beams are triggered while the gate is closing in pedestrian mode, the gate will only return to the preprogrammed pedestrian open posi on.
  • Page 14 Basic opera ng “Loop” trigger. features The Loop trigger mode is exactly the same as Condominium auto-close mode. The only way to trigger loop detector mode is via the hardwired LPT input. In Loop detector mode, a LPT trigger is treated as open, and any BT or LPT trigger is treated as a keep opening, keep open triggers or re-open trigger while the gates are running.
  • Page 15 Auxiliary relay modes. Basic opera ng Strike lock mode. features With Strike lock mode selected, the auxiliary relay will pulse for the preprogrammed on me, half a second before the gate opens. Whenever a lock is installed with the system, a separate ba ery backed up power supply matching the lock load must be installed. Failure to do this can damage the charger and ba ery of the control unit.
  • Page 16 Auxiliary relay modes. Basic opera ng features Magne c lock mode. With Magne c lock mode selected, the auxiliary relay will ac vate, half a second before the gate opens and remain ac vive un l half a second a er the gate has closed again.
  • Page 17 Auxiliary relay modes. Basic opera ng Courtesy light mode. features With courtesy light mode selected, the auxiliary light will switch on as the gate begins opening and remain on for the programmed light on me a er the gate has closed. The auxiliary relay can also be triggered to switch on without the gate opening by simply pressing and releasing any remote bu on programmed into the auxiliary relay func on of the receiver.
  • Page 18 Auxiliary relay modes. Basic opera ng features Receiver relay mode. With receiver relay mode selected, the auxiliary relay will operate in exactly the same way as a single channel receiver would, whenever a transmi er bu on programmed into the “Relay” receiver func on is pressed and released. Latch mode.
  • Page 19 Posi ve close mode. Advanced features With posi ve close mode ac vated, the gate will surge onto the closed stopper a er seeing the closed limit. This feature is useful when installing an electric lock or when trying to ensure an electric fencing gate contact always closes when the gate is in the closed posi on.
  • Page 20 Holiday lock-out mode. Advanced features This feature is useful at mes when access to the property needs to be disallowed to secondary level key holders, such as housekeepers or the garden service company, for extended periods of me. An example of when the holiday lock-out func on would be useful is when the home owner is away on holiday.
  • Page 21 Autoclose override/party mode. Advanced features This feature is useful at mes when the gate must be kept open for extended periods of me. In an offi ce park during business hours for instance. With auto-close override/party mode ac ve any trigger on any input will simply result in the control card beeping to indicate the gate is being kept open inten onally.
  • Page 22 Tamper alarms. Advanced features Beam tamper in closed posi on. In cases where the safety beams have been tampered with, the safety protocols will s ll allow the gates to open but will not allow the gates to close. This safety feature can be turned into a security risk by anyone with ill inten on. The safety beam input tampering alarm feature gives you a ealry warning of any tampering that may have occured while you were away from the property.
  • Page 23 Gate forced open alarm. Advanced features In a case where the gate is physically li ed off its track and forced open, the alarm output will immediately ac vate. The alarm will only reset when the gate is returned to normal secured condi on in the closed posi on. Ac on Response Gate secured in the...
  • Page 24 For further product documenta on, such as the sales brochure, visit our webpage by scanning either of the QR codes here: Drive 500 Drive 600...