EasyCon GSM www.TellSystem.eu Device description and function The GSM device can be used for remote controlling (ex.: gate opener) and as an accessory to alarm centers. The module has 2 contact driven inputs and one open collector output. By using a relay it is possible for the output to be a relayed output.
EasyCon GSM www.TellSystem.eu LED signals Signals give essential information on module state, the GSM signal strength and the actual error codes. By blinking we mean flashes between two longer pauses. A STATUS LED (green) gives feedback of signal strength based on the chart below:...
EasyCon GSM www.TellSystem.eu Start the Update driver process ✔ In the installation window choose the manual selection of the driver location then choose the ✔ appropriate folder containing the 32 or 64 bit driver Click on the Next button to start the installation.
EasyCon GSM www.TellSystem.eu Connecting process Pick which connection (USB or Bluetooth) you would like to use for module programming. Below the language selection in the scroll down list you can select the port through which you would like to communicate with the module programmer.
Page 9
EasyCon GSM www.TellSystem.eu Before sending your settings make sure those will not trigger an unexpected alert. You should readout the actual module state beforehand (Maintenance tab). WARNING! After connection always readout the settings first if you would like to alter those.
EasyCon GSM www.TellSystem.eu Event Log Readout The event log can be viewed with Service →Log readout button: It can store up to 16.000 events in FILO (first in-last out) mode The acquired list can be saved in ‘’csv” file for later examination. This can be done also in the event list by clicking the ‘’Open csv”...
Page 11
EasyCon GSM www.TellSystem.eu Saving phone numbers for notification • In the phone number tab you can set those phone numbers to which SMSs and/or voice messages will be forwarded. Numbers given in this section must be in international format to ensure safe operation.
EasyCon GSM www.TellSystem.eu Input configuration The GSM module has “dry” contact inputs. Before reviewing settings examine input wiring possibilities in the picture below. The two outputs can have individual settings. Figure 5. Two possible wiring of Normal Open (NO) and Normal Close (NC) inputs You can set on this tab if there is an alarm event caused by short or open circuit on an input to which phone number you would like to send SMS or voice message notification.
EasyCon GSM www.TellSystem.eu initiate an alarm event. This function is suggested when you want the module power-on to initiate an alarm event. In the SMS message box you can set the message that can be maximum 32 characters long.
NO/NC relay output output The OC relay has to be connected directly through its “+12V” and ‘’Out” series terminal with EasyCon GSM power source and with the (O) output. OC relay has a protecting diode so mind particularly the correct wiring. At switched wiring the output might get damaged.
EasyCon GSM www.TellSystem.eu Anti Jammer System (AJS) settings By using a GSM jamming device the GSM module can be sabotaged by suppressing heavily the network signal strength complete suspension. The Anti Jammer System (AJS) is monitoring the changes in signal strength of the GSM network.
EasyCon GSM www.TellSystem.eu Using your own signal (ContactID) codes The module can forward also self generated signals (ex. signals to inputs) to remote surveillance. Contact ID and Zone codes can also be altered. Notification can be revised under the Servicing ->...
Page 17
EasyCon GSM www.TellSystem.eu Entry postponing used with delayed input Exit postponing defines the time devoted to leave zones after arming Setting SMS message when alarm comes in effect (SMS command: 1234SMSTEXT16=sms text*). PC security code modification (at empty field the code is not required) ...
EasyCon GSM www.TellSystem.eu Programming with Android based mobile phone Androread Connecting to the module You can download the application in the Google Play for free without ads. When you launch the application first you must pair the choosen GSM module with the Androread.
EasyCon GSM www.TellSystem.eu Programming with SMS commands Module can also be programmed by SMS commands. SMS must start always with the security code that can be modified whenever you want. Commands can be piled but the SMS length must be under 160 characters.
EasyCon GSM www.TellSystem.eu Description SMS command x value value after = sign Example Life sign sending LIFETEST = cccsstttttttt 1234LIFETEST=0071100100100 ccc→cycle time, how often -in 7 days to send message (ex.:030 -at 11 a.m. days) -sending to 3 and 6 telephone ss→on the given day at...
EasyCon GSM www.TellSystem.eu GSM gate control compact view Similar to the entryphone compact view GSM gate control settings have their separate interface. The new interface contains every significant function for establishing a GSM based gate control system. To activate the interface on the Connection window the Gate control compact view checkbox has to be marked The new interface contains: •...